Power
Supplies
200W/400W Peak
•
•
Built-in active PFC
•
UL/CSA/EN 60950-1, 2
nd
edition (ITE)
ANSI/ANMI/CSA/EN 60601-1, 3
rd
edition (Medical)
•
Efficiency: 90% typical
Operation from -20°C to 65°C - convection
•
Approved for 2xMOPP applications
•
U-Frame (EU) and enclosed (EC) versions available
•
10 year warranty
EU Option
EC Option
Description
The
DG200 (ITE)
and
DG200M (Medical) Series
is a 200 Watt Open Frame power supply that is 3’’x 5’’x 1.42’’ providing
9.4 Watts per cubic inch. Each unit has a built in Active Power Factor Correction and the efficiency of the series is typically
90% depending on model. The DG200 is compliant with Green power, Energy Star Level VI and ErP EC 1275/2008. The Series
is rated at 200 Watts free air convection cooling and up to 300 Watts with 18CFM forced air. This series is available with an
optional “U” frame (EU) or covered metal enclosure (EC).
Specifications
Input
Input Voltage
Input Frequency
Inrush Current
Power Factor
Input Protection
No Load Input Power
Input Current
•
•
•
•
•
•
•
90 VAC to 264 VAC, 115/230V nominal
47 Hz to 63 Hz
< 30/60A at 115/230 VAC, cold start, 25ºC
>0.9
Internal T3.15 A / 250 VAC fuse in line
< 0.5W (< 1.5W for “A” version)
4A max at 115 VAC, 2A max at 230VAC
General
Efficiency
Energy Saving
Isolation
•
•
•
>90% typical at rated load
Energy Star, Level VI
4000 VAC Input to Output, 2 x MOPP
1500 VAC Input to Ground, 1 x MOPP
1500 VDC Output to Ground, 1 x MOPP
50 MΩ
120 kHz typical
>TBD kHrs to MIL-HDBK-217F at 50°C
Isolation Resistance
Switching Frequency
MTBF
•
•
•
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
•
•
•
•
•
•
•
•
•
•
•
See tables on page 2
See tables on page 2
No minimum load required
2 ms typical
> 20 ms typical
±0.5% typical
±1.0% typical
< 1% pk-pk typical, 20MHz Bandwidth
latch off
auto recovery
auto recovery
EMC & Safety
•
•
•
Harmonic Currents
•
EMI •
ESD Immunity
•
Radiated Immunity
•
EFT Burst
•
Surge
•
Conducted Immunity
•
Magnetic Fields
•
Dips & Interruptions
•
Safety Approvals:
UL/CSA/EN 60950-1, 2nd edition (ITE)
ANSI/AMMI/CSA/EN 60601-1, 3rd edition
CE Mark and CB report
EN 61000-3-2 class D
EN55022 (CISPR 22) Class B, EN 61000-3-3
EN 61000-4-2, 6kV/contact, 8kV/air
EN 61000-4-3, 10V/m with 80% AM
EN 61000-4-4, 2kV
EN 61000-4-5, 1kV/L-L, 2kV/L-G
EN 61000-4-6, 10V with 80% AM
E61000-4-8, 10A/m
EN 61000-4-11, 30% dips 10ms, 60%
dips 100ms, 95% dips 5000ms
Environmental
Operating Temperature
Cooling
Operating Humidity
Storage Temperature
Altitude
•
•
•
•
•
-20°C to 65°C
derating: 3.33% / ºC > 50°C
200W; free air convection
300W; 18CFM forced air
5-95% RH, non-condensing
-40°C to +85°C
0 to 3000 m
Warranty
Manufacturer’s Warranty
•
10 years. Call Tri-Mag or go to
www.Tri-Mag.com for details.
1601 N. Clancy Ct. • Visalia, CA 93291 • (559) 651-2222 • FAX (559) 651-0188 • sales@tri-mag.com •
tri-mag.com
1 of 2
GREEN POWER
DG200 Series
|
ITE & Medical Safety
Power
Supplies
DG200 Series
|
ITE & Medical Safety
Output Specifications
Model No.
DG200(M)-7
DG200(M)-7A
DG200(M)-8
DG200(M)-8A
DG200(M)-3
DG200(M)-3A
DG200(M)-9
DG200(M)-9A
DG200(M)-G
DG200(M)-GA
DG200(M)-J
DG200(M)-JA
DG200(M)-14
DG200(M)-14A
Application
ITE/Medical
ITE/Medical
ITE/Medical
ITE/Medical
ITE/Medical
ITE/Medical
ITE/Medical
Output Rail
+12V
+15V
+18V
+24V
+28V
+36V
+48V
Load (A)
Min
0
0
0
0
0
0
0
Rated
16.5
12.0
11.1
8.4
7.2
5.6
4.2
Max
25.0
18.0
16.6
12.5
10.7
8.3
6.3
Peak
33.0
22.5
22.3
16.7
13.0
11.0
8.4
Voltage Accuracy
+11.9V~+12.1V
+14.9V~+15.1V
+17.9V~+18.1V
+23.9V~+24.1V
+27.9V~+28.1V
+35.8V~+36.2V
+47.8V~+48.2V
Ripple Noise
<120mVpp
<150mVpp
<150mVpp
<200mVpp
<200mVpp
<250mVpp
<250mVpp
Line Reg.
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
Load Reg.
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
Notes
1.
Output Load:
Convection cooling: 200W; forced-air cooling: 300W max
2.
Peak Load Duration:
400W peak rating for durations up to 5 secs. (Duty cycle <10%, avg. power <200W)
3.
Engineering Specification:
Contact Tri-Mag for full engineering specification for the specific part number used in your design application.
4.
Standby Power Cosumption with System:
This is required by ENERGY STAR in U.S. and ErP regulation in Europe for appliances such as computers and displays. The latest
requirement is measured input power to be less than 0.5W with system.
5.
Audible Noise:
For the DG200(M)-x energy saving series, achieving Level VI (<0.3W) standby power consumption is accomplished through burst
mode operation of the controller. The burst operation frequency is dependent on load conditions and is approx. 114Hz, within the
audible frequency range.
6.
Step Efficiency and Average Efficiency:
Test conditions in step efficiency are referred to 3.2.2 IPS (Internal Power Supply) of the ENERGY STAR program requirements for
computers. ENERGY STAR required for efficiency @ 20%, 50%, 100% load is 84.5%, 89% and 86.5%; average efficiency is the
average of step efficiency.
8. Optional chassis enclosure ordering information:
7.
Model Ordering Table:
U-Frame (EU): DG-200(M)-x(A)EU
Safety/Application
w/o Audible Noise
Energy Saving
Enclosure (EC): DG-200(M)-x(A)EC
ITE
DG200-xA (EU) or (EC)
DG200-x (EU) or (EC)
Medical
DG200M-xA (EU) or (EC)
DG200M-x (EU) or (EC)
Mechanical Specifications
Notes
1.
Mechanical drawing dimensions in mm Tolerance: ± 0.4mm
2.
Size:
76.2 x 127 x 36.1 Max. (mm)
3.0 x 5.0 x 1.42 Max. (inches)
3.
Packing:
Net weight: 353 g approx. / unit
4. Connections: AC Input:
PCB Header: JST B2P3-VH or equivalent
Mating Connector: JST VAR-2, VHR-3N or equivalent
DC Output: PCB Header: JST B8P-VH or equivalent
Mating Connector: JST VHR-8N or equivalent
Terminal Block (optional)
Fan/Remote
sense:
PCB Header: Molex 22-04-1021 (5045-02A) or equivalent
Mating Connector: Molex 22-01-1022 (5051-02) or equivalent
1601 N. Clancy Ct. • Visalia, CA 93291 • (559) 651-2222 • FAX (559) 651-0188 • sales@tri-mag.com •
tri-mag.com
2014-10
2 of 2