EEWORLDEEWORLDEEWORLD

Part Number

Search

CPS16-NC00A10-SNCSNCNF-RI0CWVAR-W1077-S

Description
SWITCH PUSH SPST-NC 100MA 42V
Categoryaccessories   
File Size792KB,8 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

CPS16-NC00A10-SNCSNCNF-RI0CWVAR-W1077-S Overview

SWITCH PUSH SPST-NC 100MA 42V

CPS16-NC00A10-SNCSNCNF-RI0CWVAR-W1077-S Parametric

Parameter NameAttribute value
typecapacitive, luminous
circuitSPST-NC
switch functionOn-momentary
Rated current100mA(AC/DC)
Rated voltage - AC42V
Rated voltage - DC60V
Actuator typeround, button, flat
Color - Actuator/Capsilver
lighting type, colorLED, cyan/white
Lighting voltage (nominal)5 ~ 28 VDC
Installation typeFront panel installation
Terminal typeWire leads
Intrusion protectionIP67 - dust and water resistant
characteristicpower symbol
Panel opening sizeRound - 16.10mm diameter
Operating temperature-40°C ~ 60°C
Mechanical life-
Electrical life-
Metal Line Switches
https://www.schurter.com /PG70
CPS
Capacitive switch
See below:
Approvals and Compliances
Description
- Capacitive touch sensor as momentary push button (NO or NC) or as
latching switch (LA)
- Protection against unintended switching
- Multicolor illumination
- Floating switch connections
- Laser lettering possible
- Vandal resistant
- Wires (8 wires for Multicolor, 4 wires otherwise)²
Characteristics
- Housing made from stainless steel
- Various illumination colors and color combinations possible
- Touch surface made from scratch-resistant ceramics with area illumi-
nation or made from stainless steel with ring illumination
- Ring or area illumination
- Wearless, no moving parts
- Attractive design with or without finger guide available
Weblinks
Unique Selling Proposition
-
-
-
-
Variable supply voltage
Constant LED intensity
Inputs protected against overvoltage
Galvanic separated outputs
html-datasheet, General Product Information, CAD-Drawings, Product
News, Detailed request for product, Microsite
Important information
- The CPS is not suitable for use in sanitary or other applications exposed to water or other liquids.
- The housing is connected to gnd.
Technical Data
Electrical Data
Switching Function
Switching Voltage
Switching Current
Electrical Rating
Switch Resistance OFF
Switch Resistance ON
Supply Voltage
Current Consumption all LEDs
off
Current Consumption 1 LED
on
Current Consumption 2 LED
on
Current Consumption 3 LED
on
Reverse Polarity Protection
Short Circuit Protection
Output Type
connection type
momentary (NO¹) or latching
max. 42 VAC␣/ 60 VDC
max. 100 mA
1W
> 10 MΩ
< 16
Ω
5 - 28 VDC
2.5 mA (switch is open)
8.5 mA (switch is closed)
8.0 mA (switch is open)
14.0 mA (switch is closed)
14.0 mA (switch is open)
20.0 mA (switch is closed)
19.0 mA (switch is open)
25.0 mA (switch is closed)
yes
yes
OptoMOS Relay
Wires (8 wires for Multicolor, 4 wires
otherwise)²
Mechanical Data
Actuation Type
Actuating Force
Shock Protection
Mounting Depth
Tightening Torque Plastic Nut
Climatical Data
Operating Temperature
Storage Temperature
IP Protection Class Front Side
Salt Spray Test (acc. to DIN
50021-SS)
Material
Housings
Actuator
Illuminated Ring (Ring Illumi-
nation)
Seal Ring
capacitive
none
IK 09
with Finger Guide: 30.3 mm
without Finger Guide: 30 mm
2.5 Nm
-40 to +60 °C
-40 to +85 °C
IP 67 acc. to IEC 60529
24 h / 48 h / 96 h Residence Time
Stainless Steel
Area Illumination: Ceramics
Ring Illumination: Stainless steel
PMMA
NBR70
¹ on request also available as NC / ² on request also available with cable or connector
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Switches
1
HP laser printer original toner cartridges are useless if you don't open them after using them up.
HP Laser Printer Original Toner Cartridge Disassembly sequence :Today is the Dragon Boat Festival . I am alone in a foreign land, missing my hometown, and expressing my loneliness and feelings. I feel...
彭丙浩 Making friends through disassembly
Problems caused by macros that IAR cannot find defaulting to 0
Dear big guys When switching from Keil to IAR, there will be a warning for macros that are not defined in Keil, but there will be no alarm for macros that are not defined in IAR. The default value wil...
jialaolian stm32/stm8
What is the difference between synchronous serial port SSP and universal synchronous asynchronous receiver transmitter USART?
What is the difference between the synchronous serial port SSP and the universal synchronous asynchronous receiver transmitter USART? Which one is generally used?...
kingor2006 Embedded System
GPIO push-pull mode and open-drain mode in ARM
Please give a brief introduction to the push-pull and open-drain modes of GPIO in ARM...
hu820 ARM Technology
Why can’t I insert column COLUMN in LIST CTRL? Urgent question
Why can't I insert column COLUMN in LIST CTRL? Code: BOOL InitListView(HWND hwndLV) { LV_COLUMN lvc; int i; TCHAR *szColumn[] = {_T("HosN"), _T("PatN"), _T("PatID ")}; int widths[] = {120,100,130}; hw...
hyw123456 Embedded System
Experts, how can I use EVC to write a joystick test program under WINCE?
I use a HJ6-RS232 joystick to communicate with an embedded single-board computer through a serial port for industrial control. It is an SBC9315 single-board computer with an ARM920T core and runs Wind...
ta7680cd7698 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1686  553  2280  2748  63  34  12  46  56  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号