ACS 600V CABLE LIMITER 10AWG COP
CategoryCircuit protection   
File Size641KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet View All

LFCL0010ZC3 Online Shopping

Suppliers Part Number Price MOQ In stock  
LFCL0010ZC3 - - View Buy Now

LFCL0010ZC3 Overview

ACS 600V CABLE LIMITER 10AWG COP

POWR-GARD
®
Fuse Datasheet
LFCL CABLE LIMITERS
250/600 VAC
Description
Cable limiters are fusible devices that provide very fast short-
circuit protection, primarily to faulted cables, but also to other
conductors such as busway. Cable limiters do not have an
ampere rating, and cannot be used to provide overload protection.
They are instead selected by cable size; for example, a 500 kcmil
cable requires a 500 kcmil cable limiter. Their main use is to
isolate faulted cables in circuits containing three or more parallel
conductors per phase. They may be installed on the line side of
the main service to provide short-circuit protection to the service
conductors. This is especially important when service conductors
are tapped from large low voltage networks or from large low
impedance transformers.
Cable limiters have terminals which permit them to be installed in a
variety of equipment. The most common configuration is the offset
blade on one end and the crimp terminal on the other end. This
permits the limiter to replace a cable terminal (lug).
TYPE
TERMINATION
VOLTAGE
RATING
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
250 VAC
250 VAC
250 VAC
250 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
600 VAC
COPPER
CABLE SIZE
4 AWG
3 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
12 AWG
10 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
350 kcmil
500 kcmil
600 kcmil
750 kcmil
2/0 & 3/0 AWG
3/0 AWG
350 kcmil
600 kcmil
4/0 AWG
250 kcmil
350 kcmil
500 kcmil
750 kcmil
4/0 AWG
250 kcmil
500 kcmil
ORDERING
NUMBER
LFCL0004ZC1
LFCL0003ZC1
LFCL0002ZC1
LFCL0001ZC1
LFCL01/0ZC1
LFCL02/0ZC1
LFCL03/0ZC1
LFCL04/0ZC1
LFCL0250ZC1
LFCL0350ZC1
LFCL0500ZC1
LFCL0600ZC1
LFCL0750ZC1
LFCL1000ZC1
LFCL0012ZC3
LFCL0010ZC3
LFCL0006ZC3
LFCL0004ZC3
LFCL0002ZC3
LFCL0001ZC3
LFCL01/0ZC3
LFCL02/0ZC3
LFCL03/0ZC3
LFCL04/0ZC3
LFCL0250ZC3
LFCL0350ZC3
LFCL0500ZC3
LFCL0600ZC3
LFCL0750ZC3
LFCL-UHA*
LFCL-UHJ-M*
LFCL-UHJ-T*
LFCL-UHJ-W*
LFCL04/0ZC5*
LFCL0250ZC5*
LFCL0350ZC5*
LFCL0500ZC5*
LFCL0750ZC5*
LFCL04/0ZC6
LFCL0250ZC6
LFCL0500ZC6
1
CABLE TO CABLE
Applications
• Service Entrance Conductors
• Between Transformer or network bus and bus-way terminal
boxes as secondary ties.
• Feeders with three or more conductors per phase to share
heavier load in large commercial and industrial installations
• Multiple Single conductor services, tapped from single
(utility) transformer in multi-family residential and small
commercial installations.
3
CABLE TO
OFFSET BUS
Features
• Current-limiting characteristics provide protection to conductor
insulation and reduce damage when faults occur.
• Properly applied cable limiters may permit the use of
equipment with reduced withstand ratings
• Wide variety of terminations and cable ratings permit use in
almost every situation.
5
STRAIGHT BUS TO
OFFSET BUS
Specifications
Voltage Ratings
Interrupting Rating
Cable Size Range
Approvals
Recommended
Installation Tool
250 VAC, 600 VAC
100 kA (250 VAC), 200 kA (600 VAC)
12 AWG – 1000Kcmil Copper
Contact Tech-Line at 800-TEC-FUSE
Make:
Thomas & Betts
Crimp Tool:
TBM14_, TBM15_
6
MOLE TO CABLE
*Suitable for use with aluminum cables/conductors.
For sizing contact Tech-Line at 800-TEC-FUSE.
Web Resources
For additional information, see website:
Littelfuse.com/lfcl
Littelfuse.com
1 of 3
© 2017 Littelfuse POWR-GARD
®
Products
Rev: 101017
Looking for a hardware design solution!
Our company wants to develop a hardware product that integrates temperature, pressure, camera, nuclear detector and other sensors. All the collected data are sent to the PC through the network port of...
wowow Embedded System
WINCE touch screen calibration problem
I use a capacitive touch screen under WINCE5.0. Since the RAM registry is used, the parameters after touch screen calibration cannot be saved. So I first calibrate and read the calibrated [color=#000]...
h6003113 Embedded System
3d library.
Why can't I find the library for the SMD electrolytic capacitors? What is this package called? I can't find the 3D model for the connector. The pins are opposite to the pads. The model is very far awa...
大发明家 PCB Design
Can vs2005 use Windows Mobile 6.0?
I have installed vs2005, but I have a question: can vs2005 be used with Windows Mobile 6.0? And if it can be used, please tell me the installation steps, thank you!!!...
bcss Embedded System
Ask about the dynamic link library call problem of porting the Linux library to wince
I generated a dynamic link library on evc, and then used it in the MFC project to test that this dynamic link library is available, but now I use it in the Application project and it can run, but the ...
niux Linux and Android
RT-Thread driver chapter: hwtimer reload value algorithm
Hardware Timer Different from the two timers implemented by the rt-thread kernel, this timer relies on the built-in timer peripheral of the chip and relies on a stable and high-speed crystal oscillato...
Fillmore Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 544  2761  2488  2510  2079  11  56  51  42  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号