G3PE-545B-3 DC12-24

Description
RELAY SSR 45A 3PH SCREW 3PL
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size7MB,32 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

G3PE-545B-3 DC12-24 Overview

RELAY SSR 45A 3PH SCREW 3PL

G3PE-545B-3 DC12-24 Parametric

Parameter NameAttribute value
Installation typeBase installation
circuit3PST-NO(3 Form A)
Output typeAC, zero crossing
Load current45A
Voltage - input12 ~ 24VDC
Voltage - Load200 ~ 480 V
Terminal typescrew terminal
Package/casingSSR with integrated heat sink
Solid State Relays for Heaters
G3PE-Single-phase
Compact, Slim-profile SSRs with Heat
Sinks. Models with No Zero Cross for
a Wide Range of Applications.
• RoHS compliant.
• Models also available with no zero cross
• Surge pass protection improved surge dielectric strength for
output currents. (OMRON testing)
• Compact with a slim profile.
• Mount to DIN Track or with screws.
• Conforms to UL, CSA, and EN standards (TÜV certification).
Refer to
Safety Precautions
at the end of this document.
Ordering Information
List of Models
Number of
phases
Insulation
method
Operation
indicator
Rated input
voltage
Zero cross
function
Applicable load
*
Model
15 A, 100 to 240 VAC
G3PE-215B DC12-24
Yes
25 A, 100 to 240 VAC
G3PE-225B DC12-24
35 A, 100 to 240 VAC
G3PE-235B DC12-24
45 A, 100 to 240 VAC
G3PE-245B DC12-24
15 A, 100 to 240 VAC
G3PE-215BL DC12-24
No
Single-phase
Phototriac
coupler
Yes (yellow)
12 to 24 VDC
Yes
25 A, 100 to 240 VAC
G3PE-225BL DC12-24
35 A, 100 to 240 VAC
G3PE-235BL DC12-24
45 A, 100 to 240 VAC
G3PE-245BL DC12-24
15 A, 200 to 480 VAC
G3PE-515B DC12-24
25 A, 200 to 480 VAC
G3PE-525B DC12-24
35 A, 200 to 480 VAC
G3PE-535B DC12-24
45 A, 200 to 480 VAC
G3PE-545B DC12-24
15 A, 200 to 480 VAC
G3PE-515BL DC12-24
No
25 A, 200 to 480 VAC
G3PE-525BL DC12-24
35 A, 200 to 480 VAC
G3PE-535BL DC12-24
45 A, 200 to 480 VAC
G3PE-545BL DC12-24
*
The applicable load current depends on the ambient temperature. For details, refer to
Load Current vs. Ambient Temperature
in
Engineering
Data.
1226

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 264  395  1518  352  575  6  8  31  12  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号