1620-2-30A

Description
CIR BRKR THRM 30A 12VDC
CategoryCircuit protection   
File Size221KB,2 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Environmental Compliance
Download Datasheet Parametric View All

1620-2-30A Online Shopping

Suppliers Part Number Price MOQ In stock  
1620-2-30A - - View Buy Now

1620-2-30A Overview

CIR BRKR THRM 30A 12VDC

1620-2-30A Parametric

Parameter NameAttribute value
Circuit breaker typeThermal type
Rated current30A
Rated voltage - DC12V
Number of poles1
Actuator typeAutomatic reset
illumination-
Lighting voltage (nominal)-
Installation typeSupport
Thermal automotive Mini-CBE 1620-...
Description
Single pole, thermal miniaturised circuit breaker designed for automotive
applications. Fits into fuse blocks designed to ISO 8820-3, Type F.
Automatic reset (for DC 12 V only) and open circuit (modified reset to
SAE) version optional. Open circuit version ensures contacts staying
open as long as power is on. The circuit breaker will reset after the
load is removed. Particularly suitable for installation in inaccessible
locations.
Current ratings correspond to those of blade fuses. Clear colour
coding of the ratings: blade fuse and circuit breaker of the same colour
have the same rating.
Meets the requirements of SAE J553.
US patent number:
US 8,576,042,B2
1
1620-1/-2
Technical data
1620-3
1620-3H
Typical applications
Protection of electrical systems of passenger cars, trucks, buses,
watercraft, extra low voltage wiring systems.
Voltage rating
Max. voltage rating
Current ratings
Ordering information
Type No.
1620
single pole thermal Mini-CBE with standard characteristic curve
Version, according to SAE J553
1
type 1, DC 12 V automatic reset
2
type 2, DC 12 V modified reset
3
type 3, DC 24 V with reset button
3H
type 3*, DC 24 V with reset button and manual release facility
Current ratings
5
7.5
10
15
20
25 30 A
1620 - 1 - 10 A
ordering example
1620-1/-2: DC 12 V
1620-3/-3H: DC 12 V, DC 24 V
1620-1/-2: DC 14.5 V
1620-3/-3H: DC 29.0 V
DC 12 V: 5...30 A
DC 24 V: 5...25 A
300 operations at 2 x I
N
-40...+85 °C (-40…+185 °F)
(for higher temperatures please enquire)
≤ 15 s
Service short-circuit
breaking capacity
Ambient temperature
Reset period for 1620-1
(at 23 °C)
Reset period for 1620-2
(at 23 °C) after 5 sec at
rated voltage
Degree of protection
(IEC 60529)
< 35 s
operating area IP40 (-3)
operating area IP50 (-1, -2)
terminal area IP00
≥ 3 break operations at 150 A, or
≥ 1 break operation at 2,000 A
10 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
SAE-J553, Step No. 14, § 4.2.7.1.5
50 g (11 ms)
to IEC 60068-2-27, test Ea
SAE-J553, Step No. 14, § 4.2.7.1.6
48 hrs in 5 % salt mist,
to IEC 60068-2-11, test Ka
SAE-J553, Step No. 14, § 4.2.7.1.3
240 hrs in 95 % RH,
to IEC 60068-2-78, test Cab
SAE-J553, Step No. 14, § 4.2.7.1.2
approx. 3 g
Current ratings, typical voltage drop values and colour coding
Current rating (A)
5
7.5
10
15
20
25
30
Voltage drop (mV)
< 150
< 150
< 150
< 150
< 150
< 150
< 150
Housing cap colour
light brown
brown
red
blue
yellow
white
light green
Ultimate short-circuit
breaking capacity
Vibration
Shock
Corrosion
Humidity
Mass
Caution:
It is good practice to switch off the vehicle’s ignition system before
manually releasing or re-setting the circuit breaker. Free travel of the
reset button must be ensured! Please ensure to push in the actuator
smoothly and completely.
Depending on the socket used and with the 30 A device carrying a
full load, the temperatures at the terminals may rise above the allowed
SAE value.
1725
www.e-t-a.de
1
Ask: What is 8254A in protues
Question: My supervisor requires a graduation project, an 8086 simulation based on protues. One of the experiments requires the use of an 8254A chip, but I don't know what 8254A is called in protues?...
12315zrl Embedded System
Is the 4680 tab-free battery epoch-making for new energy vehicles?
On February 19, 2022, Tesla announced through its official social platform that it had produced the one millionth 4680 battery in January . At Tesla's Battery Day held in September last year, Tesla do...
buildele Power technology
Read protection of STM8S103K3
After reading the document, I feel that the protection measures are no different from those of MEGA88.ATMEL refuses to admit that MEGA88 can be decrypted. However, it is true that you can get the comp...
方案公司 stm32/stm8
Applications of TUSB3410
Has anyone used TUSB3410? I want to use it to make a USB to serial port conversion device. Is it possible? How to do it?...
guo8113 Microcontroller MCU
How to add a toolbar to an EVC dialog-based project?
As the title says, add a toolbar to a dialog-based project, add a button and a close cross on it, and it can be used normally. I have tried many times, but it doesn't work....
zjxgl Embedded System
Air mouse based on Renesas MCU
Use Renesas MCU to read the data of MPU6050, use 24101 to send the status data of the mouse to the receiving end connected to the computer, and control the computer mouse to complete the movement, scr...
IC爬虫 Renesas Electronics MCUs

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 41  1427  1669  2830  1292  1  29  34  57  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号