4 Volt Rating at +85°C (2.7 Volt Rating at +125°C)
T409A225(1)004(2)(3)(4)
CWR09C(3)225(1)(2)(5)
1.0
T409B475(1)004(2)(3)(4)
CWR09C(3)475(1)(2)(5)
1.0
T409C685(1)004(2)(3)(4)
CWR09C(3)685(1)(2)(5)
1.0
T409D106(1)004(2)(3)(4)
CWR09C(3)106(1)(2)(5)
1.0
T409E156(1)004(2)(3)(4)
CWR09C(3)156(1)(2)(5)
1.0
T409F336(1)004(2)(3)(4)
CWR09C(3)336(1)(2)(5)
2.0
T409G686(1)004(2)(3)(4)
CWR09C(3)686(1)(2)(5)
3.0
T409H107(1)004(2)(3)(4)
CWR09C(3)107(1)(2)(5)
4.0
6 Volt Rating at +85°C (4 Volt Rating at +125°C)
T409A155(1)006(2)(3)(4)
CWR09D(3)155(1)(2)(5)
1.0
T409B335(1)006(2)(3)(4)
CWR09D(3)335(1)(2)(5)
1.0
T409C475(1)006(2)(3)(4)
CWR09D(3)475(1)(2)(5)
1.0
T409D685(1)006(2)(3)(4)
CWR09D(3)685(1)(2)(5)
1.0
T409E106(1)006(2)(3)(4)
CWR09D(3)106(1)(2)(5)
1.0
T409F226(1)006(2)(3)(4)
CWR09D(3)226(1)(2)(5)
2.0
T409G476(1)006(2)(3)(4)
CWR09D(3)476(1)(2)(5)
3.0
T409H686(1)006(2)(3)(4)
CWR09D(3)686(1)(2)(5)
4.0
10 Volt Rating at +85°C (7 Volt Rating at +125°C)
T409A105(1)010(2)(3)(4)
CWR09F(3)105(1)(2)(5)
1.0
T409B225(1)010(2)(3)(4)
CWR09F(3)225(1)(2)(5)
1.0
T409C335(1)010(2)(3)(4)
CWR09F(3)335(1)(2)(5)
1.0
T409D475(1)010(2)(3)(4)
CWR09F(3)475(1)(2)(5)
1.0
T409E685(1)010(2)(3)(4)
CWR09F(3)685(1)(2)(5)
1.0
T409F156(1)010(2)(3)(4)
CWR09F(3)156(1)(2)(5)
2.0
T409G336(1)010(2)(3)(4)
CWR09F(3)336(1)(2)(5)
3.0
T409H476(1)010(2)(3)(4)
CWR09F(3)476(1)(2)(5)
5.0
15 Volt Rating at +85°C (10 Volt Rating at +125°C)
T409A684(1)015(2)(3)(4)
CWR09H(3)684(1)(2)(5)
1.0
T409B155(1)015(2)(3)(4)
CWR09H(3)155(1)(2)(5)
1.0
T409C225(1)015(2)(3)(4)
CWR09H(3)225(1)(2)(5)
1.0
T409D335(1)015(2)(3)(4)
CWR09H(3)335(1)(2)(5)
1.0
T409E475(1)015(2)(3)(4)
CWR09H(3)475(1)(2)(5)
1.0
T409F106(1)015(2)(3)(4)
CWR09H(3)106(1)(2)(5)
2.0
T409G226(1)015(2)(3)(4)
CWR09H(3)226(1)(2)(5)
4.0
T409H336(1)015(2)(3)(4)
CWR09H(3)336(1)(2)(5)
5.0
20 Volt Rating at +85°C (13 Volt Rating at +125°C)
T409A474(1)020(2)(3)(4)
CWR09J(3)474(1)(2)(5)
1.0
T409B684(1)020(2)(3)(4)
CWR09J(3)684(1)(2)(5)
1.0
T409B105(1)020(2)(3)(4)
CWR09J(3)105(1)(2)(5)
1.0
T409C155(1)020(2)(3)(4)
CWR09J(3)155(1)(2)(5)
1.0
T409D225(1)020(2)(3)(4)
CWR09J(3)225(1)(2)(5)
1.0
T409E335(1)020(2)(3)(4)
CWR09J(3)335(1)(2)(5)
1.0
T409F685(1)020(2)(3)(4)
CWR09J(3)685(1)(2)(5)
2.0
T409G156(1)020(2)(3)(4)
CWR09J(3)156(1)(2)(5)
3.0
T409H226(1)020(2)(3)(4)
CWR09J(3)226(1)(2)(5)
4.0
25 Volt Rating at +85°C (17 Volt Rating at +125°C)
T409A334(1)025(2)(3)(4)
CWR09K(3)334(1)(2)(5)
1.0
T409B684(1)025(2)(3)(4)
CWR09K(3)684(1)(2)(5)
1.0
T409C105(1)025(2)(3)(4)
CWR09K(3)105(1)(2)(5)
1.0
T409D155(1)025(2)(3)(4)
CWR09K(3)155(1)(2)(5)
1.0
T409E225(1)025(2)(3)(4)
CWR09K(3)225(1)(2)(5)
1.0
T409F475(1)025(2)(3)(4)
CWR09K(3)475(1)(2)(5)
2.0
T409G685(1)025(2)(3)(4)
CWR09K(3)685(1)(2)(5)
2.0
T409G106(1)025(2)(3)(4)
CWR09K(3)106(1)(2)(5)
3.0
T409H156(1)025(2)(3)(4)
CWR09K(3)156(1)(2)(5)
4.0
35 Volt Rating at +85°C (23 Volt Rating at +125°C)
T409A224(1)035(2)(3)(4)
CWR09M(3)224(1)(2)(5)
1.0
T409B474(1)035(2)(3)(4)
CWR09M(3)474(1)(2)(5)
1.0
T409C684(1)035(2)(3)(4)
CWR09M(3)684(1)(2)(5)
1.0
T409D105(1)035(2)(3)(4)
CWR09M(3)105(1)(2)(5)
1.0
T409E155(1)035(2)(3)(4)
CWR09M(3)155(1)(2)(5)
1.0
T409F335(1)035(2)(3)(4)
CWR09M(3)335(1)(2)(5)
1.0
T409G475(1)035(2)(3)(4)
CWR09M(3)475(1)(2)(5)
2.0
T409H685(1)035(2)(3)(4)
CWR09M(3)685(1)(2)(5)
3.0
KEMET
Part Number
Mil-C-55365/4F
Part Number
DF %
@ +25ºC
120 Hz
Max
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
ESR
Ω
@ +25°C
100 kHz
Max
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
6.5
3.5
2.5
1.2
1.4
1.0
18.0
10.0
8.0
6.5
4.5
2.5
1.5
1.3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
B
C
D
E
F
G
H
A
B
C
D
E
F
G
G
H
A
B
C
D
E
F
G
H
(
1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert A = Non-ER; Weibull: B = 0.1%/1000 Hrs.; C = 0.01%/1000 Hrs or D = 0.001%/1000 Hrs. or
Exponential: M = 1.0%/1000 hrs., P = 0.1%/1000 hrs., R = 0.01%/1000 hrs. or S = 0.001%/1000 hrs. Reliability Level.
(3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C before Weibull Surge Current Option.
(5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibull Surge Current Option.
Add some operations in the wifi station example. After connecting to Ap, receive the following event: void sl_WlanEvtHdlr(SlWlanEvent_t *pSlWlanEvent) { unsigned char ucQueueMsg = 0;[/font][/b][/align...
Got the board, so happy
Now I will make all the information in the CD public, so that people who didn't get the board can also gain something from this event...:) :)
Let's learn LM3S811 together...[[i...
[b]Sell a set of [font="] [/font][font="]DY-FFTB6638 Deyan Electronics MSP430 development kit that I don't use, brand new, price 350 yuan, fixed price! [/font][/b]...
1. Project Overview
1.1 Introduction
Currently, most music files are saved in MP3 format, a lossy audio compression format that cannot perfectly reproduce the original music. With the exp...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
introduction
The concept of the smart home is gradually developing and gaining market acceptance. We believe its ultimate form lies in the interconnection of all home appliances through open i...[Details]
Have you ever heard stories about "crazy appliances"? Think of microwaves that turn on automatically or ovens that preheat without any human input? With radios and electromagnetic interfaces ubiqui...[Details]
Keysight Technologies is combining its electromagnetic simulator with Synopsys' AI-driven RF design migration flow to create an integrated design flow for migrating from TSMC's N6RF+ process techno...[Details]
Plessey Semiconductors has been acquired by Haylo Labs, which was established in March last year with a $100 million, five-year loan from Chinese technology company Goertek.
Haylo Labs w...[Details]
Magna's integrated in-cabin perception system fuses vision and millimeter-wave radar data to detect the presence of passengers, identify stranded children, monitor driver fatigue and vital signs, a...[Details]
Methods of DC motor speed regulation:
1. The voltage regulator can be used to change the input voltage and speed directly, which is often used for large kilowatt-level motors.
2. Thyristo...[Details]
Introduction: In digital circuit calculations, there is no concept of decimal points. You know where the decimal is, but the circuit does not know where the decimal point is. Therefore, you need to...[Details]
Hair dryer structure and working principle: It is mainly used for drying and shaping hair, but it can also be used for local drying, heating and treatment in laboratories, physiotherapy rooms, ind...[Details]
In industrial production, many different controllers are often used, such as those for pressure, flow, electrical parameters, temperature, and sound. However, due to the limitations of the on-site ...[Details]
Using the STM32F103 as a microprocessor, a low-cost wireless WiFi music player system was designed. This system, combined with the WM-G-MR-08 (wm631) module for WiFi data reception and the VS1003B ...[Details]
When installing circuits, we all hope to have a safe and protective electrical appliance. Circuit breakers and circuit breakers are such a thing. As we all know, a circuit breaker is an elect...[Details]
Mr. Wang, a BYD owner, recently experienced a "5-minute charge" at a highway service area, boasting a 400-kilometer range. He marveled at the rapid evolution of new energy technol...[Details]
Why does the xenon lamp not light up?
There are many reasons why a xenon lamp might not light up. Poor contact, a damaged component, or a blown bulb are all possible reasons. This requires a l...[Details]