4 Volt Rating at +85°C (2.7 Volt Rating at +125°C)
T409A225(1)004(2)(3)(4)
CWR09C(3)225(1)(2)(5)
1.0
T409B475(1)004(2)(3)(4)
CWR09C(3)475(1)(2)(5)
1.0
T409C685(1)004(2)(3)(4)
CWR09C(3)685(1)(2)(5)
1.0
T409D106(1)004(2)(3)(4)
CWR09C(3)106(1)(2)(5)
1.0
T409E156(1)004(2)(3)(4)
CWR09C(3)156(1)(2)(5)
1.0
T409F336(1)004(2)(3)(4)
CWR09C(3)336(1)(2)(5)
2.0
T409G686(1)004(2)(3)(4)
CWR09C(3)686(1)(2)(5)
3.0
T409H107(1)004(2)(3)(4)
CWR09C(3)107(1)(2)(5)
4.0
6 Volt Rating at +85°C (4 Volt Rating at +125°C)
T409A155(1)006(2)(3)(4)
CWR09D(3)155(1)(2)(5)
1.0
T409B335(1)006(2)(3)(4)
CWR09D(3)335(1)(2)(5)
1.0
T409C475(1)006(2)(3)(4)
CWR09D(3)475(1)(2)(5)
1.0
T409D685(1)006(2)(3)(4)
CWR09D(3)685(1)(2)(5)
1.0
T409E106(1)006(2)(3)(4)
CWR09D(3)106(1)(2)(5)
1.0
T409F226(1)006(2)(3)(4)
CWR09D(3)226(1)(2)(5)
2.0
T409G476(1)006(2)(3)(4)
CWR09D(3)476(1)(2)(5)
3.0
T409H686(1)006(2)(3)(4)
CWR09D(3)686(1)(2)(5)
4.0
10 Volt Rating at +85°C (7 Volt Rating at +125°C)
T409A105(1)010(2)(3)(4)
CWR09F(3)105(1)(2)(5)
1.0
T409B225(1)010(2)(3)(4)
CWR09F(3)225(1)(2)(5)
1.0
T409C335(1)010(2)(3)(4)
CWR09F(3)335(1)(2)(5)
1.0
T409D475(1)010(2)(3)(4)
CWR09F(3)475(1)(2)(5)
1.0
T409E685(1)010(2)(3)(4)
CWR09F(3)685(1)(2)(5)
1.0
T409F156(1)010(2)(3)(4)
CWR09F(3)156(1)(2)(5)
2.0
T409G336(1)010(2)(3)(4)
CWR09F(3)336(1)(2)(5)
3.0
T409H476(1)010(2)(3)(4)
CWR09F(3)476(1)(2)(5)
5.0
15 Volt Rating at +85°C (10 Volt Rating at +125°C)
T409A684(1)015(2)(3)(4)
CWR09H(3)684(1)(2)(5)
1.0
T409B155(1)015(2)(3)(4)
CWR09H(3)155(1)(2)(5)
1.0
T409C225(1)015(2)(3)(4)
CWR09H(3)225(1)(2)(5)
1.0
T409D335(1)015(2)(3)(4)
CWR09H(3)335(1)(2)(5)
1.0
T409E475(1)015(2)(3)(4)
CWR09H(3)475(1)(2)(5)
1.0
T409F106(1)015(2)(3)(4)
CWR09H(3)106(1)(2)(5)
2.0
T409G226(1)015(2)(3)(4)
CWR09H(3)226(1)(2)(5)
4.0
T409H336(1)015(2)(3)(4)
CWR09H(3)336(1)(2)(5)
5.0
20 Volt Rating at +85°C (13 Volt Rating at +125°C)
T409A474(1)020(2)(3)(4)
CWR09J(3)474(1)(2)(5)
1.0
T409B684(1)020(2)(3)(4)
CWR09J(3)684(1)(2)(5)
1.0
T409B105(1)020(2)(3)(4)
CWR09J(3)105(1)(2)(5)
1.0
T409C155(1)020(2)(3)(4)
CWR09J(3)155(1)(2)(5)
1.0
T409D225(1)020(2)(3)(4)
CWR09J(3)225(1)(2)(5)
1.0
T409E335(1)020(2)(3)(4)
CWR09J(3)335(1)(2)(5)
1.0
T409F685(1)020(2)(3)(4)
CWR09J(3)685(1)(2)(5)
2.0
T409G156(1)020(2)(3)(4)
CWR09J(3)156(1)(2)(5)
3.0
T409H226(1)020(2)(3)(4)
CWR09J(3)226(1)(2)(5)
4.0
25 Volt Rating at +85°C (17 Volt Rating at +125°C)
T409A334(1)025(2)(3)(4)
CWR09K(3)334(1)(2)(5)
1.0
T409B684(1)025(2)(3)(4)
CWR09K(3)684(1)(2)(5)
1.0
T409C105(1)025(2)(3)(4)
CWR09K(3)105(1)(2)(5)
1.0
T409D155(1)025(2)(3)(4)
CWR09K(3)155(1)(2)(5)
1.0
T409E225(1)025(2)(3)(4)
CWR09K(3)225(1)(2)(5)
1.0
T409F475(1)025(2)(3)(4)
CWR09K(3)475(1)(2)(5)
2.0
T409G685(1)025(2)(3)(4)
CWR09K(3)685(1)(2)(5)
2.0
T409G106(1)025(2)(3)(4)
CWR09K(3)106(1)(2)(5)
3.0
T409H156(1)025(2)(3)(4)
CWR09K(3)156(1)(2)(5)
4.0
35 Volt Rating at +85°C (23 Volt Rating at +125°C)
T409A224(1)035(2)(3)(4)
CWR09M(3)224(1)(2)(5)
1.0
T409B474(1)035(2)(3)(4)
CWR09M(3)474(1)(2)(5)
1.0
T409C684(1)035(2)(3)(4)
CWR09M(3)684(1)(2)(5)
1.0
T409D105(1)035(2)(3)(4)
CWR09M(3)105(1)(2)(5)
1.0
T409E155(1)035(2)(3)(4)
CWR09M(3)155(1)(2)(5)
1.0
T409F335(1)035(2)(3)(4)
CWR09M(3)335(1)(2)(5)
1.0
T409G475(1)035(2)(3)(4)
CWR09M(3)475(1)(2)(5)
2.0
T409H685(1)035(2)(3)(4)
CWR09M(3)685(1)(2)(5)
3.0
KEMET
Part Number
Mil-C-55365/4F
Part Number
DF %
@ +25ºC
120 Hz
Max
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
ESR
Ω
@ +25°C
100 kHz
Max
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
6.5
3.5
2.5
1.2
1.4
1.0
18.0
10.0
8.0
6.5
4.5
2.5
1.5
1.3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
B
C
D
E
F
G
H
A
B
C
D
E
F
G
G
H
A
B
C
D
E
F
G
H
(
1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert A = Non-ER; Weibull: B = 0.1%/1000 Hrs.; C = 0.01%/1000 Hrs or D = 0.001%/1000 Hrs. or
Exponential: M = 1.0%/1000 hrs., P = 0.1%/1000 hrs., R = 0.01%/1000 hrs. or S = 0.001%/1000 hrs. Reliability Level.
(3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C before Weibull Surge Current Option.
(5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibull Surge Current Option.
[b][color=#008080]1. Introduction to MSP430FRXX series MCUs[/color][/b] TI's latest generation of MSP430FRXX series MCUs uses FRAM as code and data memory, replacing the traditional MCU FLASH+SRAM str...
I've recently been learning how to port UC0S to S3C2410, which is ARM9. I downloaded someone else's ported code from the Internet and modified it a little. It can run multiple tasks. I think that sinc...
During the Spring Festival, I visited relatives and friends, went to the library, watched cartoons, and sorted out some information. I read three of Lang Xianping's latest books in two hours. I read t...
When drawing a C51 microcontroller in Protues simulation software, how to simplify the eight pins P0.0 to P0.7 into a common line, i.e. A[0...7]. What icon should be used to draw it?...
Recently, the most common word I hear in the automotive industry is connectors. I was not in this industry before, so I feel a little confused when I first come into contact with them.Connectors conne...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
The Mobile Industry Processor Interface (MIPI) Alliance is an organization responsible for promoting the standardization of software and hardware in mobile devices. It has released the D-PHY specif...[Details]
1 Introduction
Ultrasonic waves have strong directivity, slow energy consumption, and can propagate over long distances in a medium, so they are used for distance measurement. Ultrasonic detec...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]
Portable power applications are broad and varied. Products range from wireless sensor nodes with average power consumption of only a few microwatts to in-vehicle medical or data acquisition systems...[Details]
In the test of the electronic ignition module, in order to simulate the real working conditions of the electronic ignition system, the electronic ignition module is often placed in an environment h...[Details]
In order to ensure that lighting-grade white light LEDs can not only be well applied but also achieve high utilization efficiency, first of all, it is necessary to meet certain application conditions,...[Details]
0 Introduction
This paper designs a dot matrix LED text display screen that is easy to update, expandable, and low-cost. The ways to reduce costs are: ① Use the Bluetooth data transmission...[Details]
0 Introduction
In the fields of petroleum, chemical industry, metallurgy, electricity, textile, light industry, water conservancy and other industries and scientific research, relevant pressur...[Details]
With the reform of the education system, the proportion of funds invested in teaching facilities by colleges and universities has become increasingly important. As the most basic hardware condition fo...[Details]
Pure C51 reset function: A junior student, who makes people love and
fear The single-column reset part is as follows:
main()
{
unsigned char code rst ={0xe4,0xc0,0xe0,0xc0,0xe0,0x32}; ...[Details]
After the development of the single-chip microcomputer application system is completed, the system often freezes at the work site due to noise interference, electromagnetic interference, overvoltag...[Details]