4 Volt Rating at +85°C (2.7 Volt Rating at +125°C)
T409A225(1)004(2)(3)(4)
CWR09C(3)225(1)(2)(5)
1.0
T409B475(1)004(2)(3)(4)
CWR09C(3)475(1)(2)(5)
1.0
T409C685(1)004(2)(3)(4)
CWR09C(3)685(1)(2)(5)
1.0
T409D106(1)004(2)(3)(4)
CWR09C(3)106(1)(2)(5)
1.0
T409E156(1)004(2)(3)(4)
CWR09C(3)156(1)(2)(5)
1.0
T409F336(1)004(2)(3)(4)
CWR09C(3)336(1)(2)(5)
2.0
T409G686(1)004(2)(3)(4)
CWR09C(3)686(1)(2)(5)
3.0
T409H107(1)004(2)(3)(4)
CWR09C(3)107(1)(2)(5)
4.0
6 Volt Rating at +85°C (4 Volt Rating at +125°C)
T409A155(1)006(2)(3)(4)
CWR09D(3)155(1)(2)(5)
1.0
T409B335(1)006(2)(3)(4)
CWR09D(3)335(1)(2)(5)
1.0
T409C475(1)006(2)(3)(4)
CWR09D(3)475(1)(2)(5)
1.0
T409D685(1)006(2)(3)(4)
CWR09D(3)685(1)(2)(5)
1.0
T409E106(1)006(2)(3)(4)
CWR09D(3)106(1)(2)(5)
1.0
T409F226(1)006(2)(3)(4)
CWR09D(3)226(1)(2)(5)
2.0
T409G476(1)006(2)(3)(4)
CWR09D(3)476(1)(2)(5)
3.0
T409H686(1)006(2)(3)(4)
CWR09D(3)686(1)(2)(5)
4.0
10 Volt Rating at +85°C (7 Volt Rating at +125°C)
T409A105(1)010(2)(3)(4)
CWR09F(3)105(1)(2)(5)
1.0
T409B225(1)010(2)(3)(4)
CWR09F(3)225(1)(2)(5)
1.0
T409C335(1)010(2)(3)(4)
CWR09F(3)335(1)(2)(5)
1.0
T409D475(1)010(2)(3)(4)
CWR09F(3)475(1)(2)(5)
1.0
T409E685(1)010(2)(3)(4)
CWR09F(3)685(1)(2)(5)
1.0
T409F156(1)010(2)(3)(4)
CWR09F(3)156(1)(2)(5)
2.0
T409G336(1)010(2)(3)(4)
CWR09F(3)336(1)(2)(5)
3.0
T409H476(1)010(2)(3)(4)
CWR09F(3)476(1)(2)(5)
5.0
15 Volt Rating at +85°C (10 Volt Rating at +125°C)
T409A684(1)015(2)(3)(4)
CWR09H(3)684(1)(2)(5)
1.0
T409B155(1)015(2)(3)(4)
CWR09H(3)155(1)(2)(5)
1.0
T409C225(1)015(2)(3)(4)
CWR09H(3)225(1)(2)(5)
1.0
T409D335(1)015(2)(3)(4)
CWR09H(3)335(1)(2)(5)
1.0
T409E475(1)015(2)(3)(4)
CWR09H(3)475(1)(2)(5)
1.0
T409F106(1)015(2)(3)(4)
CWR09H(3)106(1)(2)(5)
2.0
T409G226(1)015(2)(3)(4)
CWR09H(3)226(1)(2)(5)
4.0
T409H336(1)015(2)(3)(4)
CWR09H(3)336(1)(2)(5)
5.0
20 Volt Rating at +85°C (13 Volt Rating at +125°C)
T409A474(1)020(2)(3)(4)
CWR09J(3)474(1)(2)(5)
1.0
T409B684(1)020(2)(3)(4)
CWR09J(3)684(1)(2)(5)
1.0
T409B105(1)020(2)(3)(4)
CWR09J(3)105(1)(2)(5)
1.0
T409C155(1)020(2)(3)(4)
CWR09J(3)155(1)(2)(5)
1.0
T409D225(1)020(2)(3)(4)
CWR09J(3)225(1)(2)(5)
1.0
T409E335(1)020(2)(3)(4)
CWR09J(3)335(1)(2)(5)
1.0
T409F685(1)020(2)(3)(4)
CWR09J(3)685(1)(2)(5)
2.0
T409G156(1)020(2)(3)(4)
CWR09J(3)156(1)(2)(5)
3.0
T409H226(1)020(2)(3)(4)
CWR09J(3)226(1)(2)(5)
4.0
25 Volt Rating at +85°C (17 Volt Rating at +125°C)
T409A334(1)025(2)(3)(4)
CWR09K(3)334(1)(2)(5)
1.0
T409B684(1)025(2)(3)(4)
CWR09K(3)684(1)(2)(5)
1.0
T409C105(1)025(2)(3)(4)
CWR09K(3)105(1)(2)(5)
1.0
T409D155(1)025(2)(3)(4)
CWR09K(3)155(1)(2)(5)
1.0
T409E225(1)025(2)(3)(4)
CWR09K(3)225(1)(2)(5)
1.0
T409F475(1)025(2)(3)(4)
CWR09K(3)475(1)(2)(5)
2.0
T409G685(1)025(2)(3)(4)
CWR09K(3)685(1)(2)(5)
2.0
T409G106(1)025(2)(3)(4)
CWR09K(3)106(1)(2)(5)
3.0
T409H156(1)025(2)(3)(4)
CWR09K(3)156(1)(2)(5)
4.0
35 Volt Rating at +85°C (23 Volt Rating at +125°C)
T409A224(1)035(2)(3)(4)
CWR09M(3)224(1)(2)(5)
1.0
T409B474(1)035(2)(3)(4)
CWR09M(3)474(1)(2)(5)
1.0
T409C684(1)035(2)(3)(4)
CWR09M(3)684(1)(2)(5)
1.0
T409D105(1)035(2)(3)(4)
CWR09M(3)105(1)(2)(5)
1.0
T409E155(1)035(2)(3)(4)
CWR09M(3)155(1)(2)(5)
1.0
T409F335(1)035(2)(3)(4)
CWR09M(3)335(1)(2)(5)
1.0
T409G475(1)035(2)(3)(4)
CWR09M(3)475(1)(2)(5)
2.0
T409H685(1)035(2)(3)(4)
CWR09M(3)685(1)(2)(5)
3.0
KEMET
Part Number
Mil-C-55365/4F
Part Number
DF %
@ +25ºC
120 Hz
Max
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
ESR
Ω
@ +25°C
100 kHz
Max
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
6.5
3.5
2.5
1.2
1.4
1.0
18.0
10.0
8.0
6.5
4.5
2.5
1.5
1.3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
B
C
D
E
F
G
H
A
B
C
D
E
F
G
G
H
A
B
C
D
E
F
G
H
(
1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert A = Non-ER; Weibull: B = 0.1%/1000 Hrs.; C = 0.01%/1000 Hrs or D = 0.001%/1000 Hrs. or
Exponential: M = 1.0%/1000 hrs., P = 0.1%/1000 hrs., R = 0.01%/1000 hrs. or S = 0.001%/1000 hrs. Reliability Level.
(3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C before Weibull Surge Current Option.
(5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibull Surge Current Option.
When using STM32 to make a project, CAN is used. The design uses 5 filter groups, which are associated with FIFO 0 and FIFO 1 respectively. The reception adopts interrupt reception. In theory, the dat...
Dear webmaster: DSP Exchange Network applies for exchanging friendly links. The website address is: [url]www.hellodsp.com[/url] Please contact us via QQ: 77 8086 555. Provide us with your website LOGO...
Still don't know what kind of components are on the circuit board, what role do different components play on the circuit board, how do these components work together, and if there is a problem, how sh...
I am working on a small system now, which involves the problem of floating-point operations. I feel that the floating-point operations of the microcontroller are a bit inaccurate:I can get data throug...
Design and implementation of communication in power supply control system Abstract: Communication is one of the key technologies in power control systems. This paper introduces in detail the design an...
In early 2002, I started to write a working program for an IC card prepaid electricity meter. The meter used Philips' 8-bit 51-expanded single-chip microcomputer
87LPC764
, and wa...[Details]
As cellular phones become more advanced, the power consumption of the system during operation and the power consumption during standby are also increasing. Therefore, the power management design of...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
Abstract: With the development and construction of BeiDou II system, China will shift from the situation dominated by GPS to the situation dominated by BeiDou II global navigation system independen...[Details]
Fruit planting is an important part of China's agricultural development, and fruit tree pest control operations are becoming more and more important. At present, the overall level of pesticide applica...[Details]
With the popularity of digital appliances, rechargeable batteries can be seen everywhere in people's daily lives and have become one of the indispensable daily necessities.
This article gives ...[Details]
When developing electronic products with processors, how to improve anti-interference ability and electromagnetic compatibility?
1. The following systems should pay special attention to anti-...[Details]
Designing low power circuits while achieving acceptable performance is a difficult task. Doing so in
the RF
bands increases the challenge dramatically. Today, nearly everything has wireless...[Details]
0 Introduction
PROFIBUS is an open digital communication system with a wide range of applications, which has been included in the international standards IEC 61158 and IEC 61784. Since the gen...[Details]
1 Introduction
In order to cope with the energy crisis and slow down global warming, many countries have begun to pay attention to energy conservation and emission reduction and the de...[Details]
There are two main ways to measure temperature: one is the traditional contact measurement, and the other is
non-contact measurement represented by
infrared temperature measurement
. Tradit...[Details]
Introduction
The LED market has seen tremendous growth over the past few years. Advances in thermal dissipation, packaging, and processing have resulted in higher brightness, higher efficien...[Details]
1. Introduction
According to the definition of the International Electrotechnical Commission (IEC) and the American Instrument Society (ISA), fieldbus is a digital, two-way transmission, multi...[Details]
1. Introduction
PROFIBUS is an international, open asynchronous serial communication standard, which is widely used in manufacturing automation and process automation, buildings, transportatio...[Details]
In order to reduce the proportion of data transmission time in the entire system processing time index, the data transmission rate should be no less than E1 (2.048Mb/s), and the communication...[Details]