EEWORLDEEWORLDEEWORLD

Part Number

Search

LRSE-18-013-A-00-10-A

Description
SPRING LOADED 1/2" RANGE, 0-10VD
CategoryThe sensor   
File Size516KB,2 Pages
ManufacturerPulseR
Environmental Compliance
Download Datasheet Parametric Compare View All

LRSE-18-013-A-00-10-A Overview

SPRING LOADED 1/2" RANGE, 0-10VD

LRSE-18-013-A-00-10-A Parametric

Parameter NameAttribute value
for measurementlinear position
technologyLVIT (Linear Variable Inductance Transmitter)
Angle of rotation - electrical, mechanical-
linear range0 ~ 12.70mm(0 ~ 0.50")
output0 V ~ 10 V
output signal-
Actuator typeround shaft
linearity±0.15%
Resistor tolerance-
Voltage - Power0 V ~ 10 V
Installation typeBase installation
Terminal typeConnector
Operating temperature-20°C ~ 85°C
LRS-18 Series
For use in:
Industrial Fluid Power Equipment
Steel, Aluminum, and Paper Mills
Steam and Hydro Power Plants
Factory Automation Systems
Spring Loaded LVIT Linear Position Sensor
Long Lasting, Contactless, Inductive Sensors
The LRS-18 series of LVIT (Linear Variable Inductance Transducer) spring loaded position sensors by Alliance
Sensors Group are contactless devices designed for dimension or position measuring applications in factory
automation and in various industrial and commercial applications such as automotive testing, mil/aero test
stands, robotic arms, and packaging equipment, where the sensing element cannot be attached to the object
being measured. LRS-18s are offered in full scale ranges from 12.5 to 100 mm (0.5 to 4.0 inches) with excellent
resolution and high stroke-to-body-length ratios. The maximum tip force on the item being measured is 1 pound.
LRS-18 sensors have a 19 mm (0.75 inch) diameter aluminum or stainless steel body with an M18 x 1 thread
and come with two hex jam nuts for easy installation in place of an 18 mm analog prox sensor. These sensors
use a 0.25 inch diameter probe equipped with an AGD No. 9 contact tip, and are offered with either an axial
cable or a connector. Operating from a variety of DC voltages, the sensors are available with a choice of four
analog outputs and they all include ASG’s proprietary SenSet
field calibration feature.
Additional information can be found at www.alliancesensors.com.
Features:
Spring loaded LVIT Technology
(Linear Variable Inductance Transducer)
Ranges from 0.5 to 4.0 inches (12.5 to100 mm)
Contactless operation prevents internal wearout from dithering or rapid cycling
Excellent stroke-to-body-length ratio
Proprietary SenSet
field adjustable range scaling
Specifications:
Analog I/Os
0 - 5 V or 0.5 - 4.5 V DC output with 8 - 30 V input, 35 mA max.
0 - 10 V DC output with 12 - 30 V input, 35 mA max.
4 - 20 mA (3-wire) output with 18 - 30 V input, 60 mA max. (75 C max.)
Measuring Ranges
12.5 mm to 100 mm (0.5 to 4.0 inches) full scale
Linearity Error
±0.15% of Full Scale Output (FSO) typical, ±0.25% max.
Resolution
0.025% of FS
Operating Temperature
-20 to 85 C (-40 to 105 C Extended Range)
Temperature Coefficient
≤±0.015% of FS/K
Vibration
5-20 Hz 0.5 inch p-p; 20-2000 Hz 4.2 g p-p
Shock
1000 g, 11 msec.
Terminations
IEC IP-67
Humidity
95% RH, non-condensing
All specifications are subject to change without notice.
© Alliance Sensors Group, 2017
v2.3 Rev. 062017

LRSE-18-013-A-00-10-A Related Products

LRSE-18-013-A-00-10-A LRSI-18-013-A-00-20-A LRSI-18-025-A-00-20-A LRSE-18-025-A-00-10-A LRSI-18-050-A-00-20-A LRSE-18-050-A-00-10-A LRSE-18-075-A-00-10-A LRSI-18-075-A-00-20-A LRSE-18-100-A-00-10-A LRSI-18-100-A-00-20-A
Description SPRING LOADED 1/2" RANGE, 0-10VD SPRING LOADED 1/2" RANGE, 4-20MA SPRING LOADED 1" RANGE, 4-20MA, SPRING LOADED 1" RANGE, 0-10VDC, SPRING LOADED 2" RANGE, 4-20MA, SPRING LOADED 2" RANGE, 0-10VDC, SPRING LOADED 3" RANGE, 0-10VDC, SPRING LOADED 3" RANGE, 4-20MA, SPRING LOADED 4" RANGE, 0-10VDC, SPRING LOADED 4" RANGE, 4-20MA,
for measurement linear position linear position linear position linear position linear position linear position linear position linear position linear position linear position
technology LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter) LVIT (Linear Variable Inductance Transmitter)
linear range 0 ~ 12.70mm(0 ~ 0.50") 0 ~ 12.70mm(0 ~ 0.50") 0 ~ 25.40mm(0 ~ 1.00") 0 ~ 25.40mm(0 ~ 1.00") 0 ~ 50.80mm(0 ~ 2.00") 0 ~ 50.80mm(0 ~ 2.00") 0 ~ 76.20mm(0 ~ 3.00") 0 ~ 76.20mm(0 ~ 3.00") 0 ~ 101.60mm(0 ~ 4.00") 0 ~ 101.60mm(0 ~ 4.00")
output 0 V ~ 10 V 4mA ~ 20mA 4mA ~ 20mA 0 V ~ 10 V 4mA ~ 20mA 0 V ~ 10 V 0 V ~ 10 V 4mA ~ 20mA 0 V ~ 10 V 4mA ~ 20mA
Actuator type round shaft round shaft round shaft round shaft round shaft round shaft round shaft round shaft round shaft round shaft
linearity ±0.15% ±0.15% ±0.15% ±0.15% ±0.15% ±0.15% ±0.15% ±0.15% ±0.15% ±0.15%
Installation type Base installation Base installation Base installation Base installation Base installation Base installation Base installation Base installation Base installation Base installation
Terminal type Connector Connector Connector Connector Connector Connector Connector Connector Connector Connector
Operating temperature -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C -20°C ~ 85°C

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2854  1291  2011  1481  391  58  26  41  30  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号