EEWORLDEEWORLDEEWORLD

Part Number

Search

4230-T120-K0BE-40A

Description
CIR BRKR THERM 40A 480VAC/125VDC
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet Parametric View All

4230-T120-K0BE-40A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T120-K0BE-40A - - View Buy Now

4230-T120-K0BE-40A Overview

CIR BRKR THERM 40A 480VAC/125VDC

4230-T120-K0BE-40A Parametric

Parameter NameAttribute value
Circuit breaker typeThermomagnetic
Rated current40A
Rated voltage - AC480V
Rated voltage - DC125V
Number of poles2
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typeDIN rail
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1
Problem choosing direction? I’m in a hurry!!
Hello everyone, I am a graduate student, in my first year of graduate school. I have been troubled by a problem for a long time, which is the choice of direction. I used to be a programmer, proficient...
yuezhiguang.4 Embedded System
Main technical indicators of the antenna
[table=523][tr][td=1,1,523][b]Main technical indicators of antennas[/b] Antenna radiation pattern[align=left] (I) Radiation pattern[/align][align=left] The distribution of the electric field intensity...
xtss RF/Wirelessly
Which company is the best in low-power MCU? If not Atmel, who else would you choose? Authentic low-power pedigree
[b][color=#ff0000]Which company is the best at low-power MCU? If not Atmel, who else would you look for? Authentic low-power pedigree! [size=5]Great[/size][/color][/b]:handshake In the past decade, At...
DreamerJane Microchip MCU
Prepare MCU 12864 Dynamic waveform display Original personal test
[i=s]This post was last edited by paulhyde on 2014-9-15 03:12[/i]It can be used to display waveforms, parameters can be displayed next to it, and commonly used driver functions. Come here if you need ...
GTao_12345 Electronics Design Contest
Flash read and write problems on wince
I used writefile to write data to a file, but did not call closehandle to close the file. When the system restarts, the content written by writefile is not saved in the memory. If I call FlushFileBuff...
zxh161987 Embedded System
System abnormality help (WinCE)
After the system is running, I connected the debugging serial port and saw that the system threw the following exception: Exception 'Raised Exception' (-1): Thread-Id=03990002(pth=835ee15c), Proc-Id=0...
flywing Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1955  1292  156  2646  1687  40  27  4  54  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号