BB-MDR-60-12

Description
AC/DC CONVERTER 12V 60W
CategoryPower/power management   
File Size378KB,2 Pages
ManufacturerB+B SmartWorx
Environmental Compliance
Download Datasheet Parametric Compare View All

BB-MDR-60-12 Online Shopping

Suppliers Part Number Price MOQ In stock  
BB-MDR-60-12 - - View Buy Now

BB-MDR-60-12 Overview

AC/DC CONVERTER 12V 60W

BB-MDR-60-12 Parametric

Parameter NameAttribute value
typeclosed
Number of outputs1
Voltage - input85 ~ 264 VAC
Voltage - Output 112V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)5A
Power (W)60W
applicationITE (Business)
Voltage - Isolation3kV
efficiency86%
Operating temperature-20°C ~ 70°C (with derating)
characteristicAdjustable output, DC input capability, universal input
Installation typeDIN rail
size/dimensions3.94" long x 1.57" wide x 3.54" high (100.0mm x 40mm x 90.0mm)
Minimum load required-
ApprovalCB,CE,cULus,TUVgs
60W Single Output Industrial DIN Rail Power Supply
Features :
Universal AC input/Full range
MDR-60
series
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Class I
,
Div 2 Hazardous Locations T4
LED indicator for power on
DC OK relay contact
No load power consumption<0.75W
www.advantech-bb.com
100% full load burn-in test
3 years warranty
..
Ultra Compact Modbus Gateways
Models MESP211D, MESP211T
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
MDR-60-5
5V
10A
0 ~ 10A
50W
5 ~ 6V
±1.0%
±1.5%
Note.5
500ms, 30ms/230VAC
PRODUCT FEATURES
MDR-60-12
MDR-60-24
24V
MDR-60-48
48V
RIPPLE & NOISE (max.)
Note.2
80mVp-p
VOLTAGE TOLERANCE
Note.3
±2.0%
Modbus TCP Ethernet, Modbus ASCII & RTU RS-232/422/485
5A
2.5A
1.25A
Modbus Flexibility – Serial & Ethernet, Masters & Slaves
0 ~ 5A
0 ~ 2.5A
0 ~ 1.25A
View Messaging Status in Real Time
60W
60W
60W
Ultra Compact IP30 Metal Enclosure
120mVp-p
150mVp-p
200mVp-p
International Power Supply (included
12 ~ 15V
±1.0%
±1.0%
±1.0%
24 ~ 30V
±1.0%
±1.0%
±1.0%
12V
48 ~ 56V
±1.0%
±1.0%
±1.0%
500ms, 30ms/115VAC at full load
ETHERNET ETHERNET
PORT
CONNECTOR
1
RJ45
1
Models MESP211D and MESP211T, Vlinx series Modbus Gateways, connect
HOLD UP TIME (Typ.)
50ms/230VAC
20ms/115VAC at full load
INFORMATION
ORDERING
Modbus devices to Ethernet networks and let you monitor
~
and control Modbus
370VDC
VOLTAGE RANGE
85 264VAC
120 ~
SERIAL
MODEL NUMBER PROTOCOL
PORT
devices from anywhere on the Ethernet LAN or WAN.
47 ~ 63Hz
up to 16
Supporting
FREQUENCY RANGE
MESP211D
RS-232/422/485 DB9 Male
masters and 32 slaves, these gateways feature an auto-detecting 10/100
EFFICIENCY (Typ.)
78%
86%
88%
MESP211T
RS-232/422/485 Removable
Ethernet
INPUT
RJ-45 port and a serial port that supports RS-232/422/485
copper
Terminal Block
AC CURRENT (Typ.)
1.8A/115VAC
1A/230VAC
communications via a DB9 male or a terminal block connection.
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START 30A/115VAC
<1mA / 240VAC
60A/230VAC
87%
RJ45
The product is built for use in industrial environments with a heavy-duty metal
ACCESSORIES
105 ~
enclosure that is panel (standard) or DIN rail mountable (with
150% rated output power
optional adapters).
OVERLOAD
SMI6-12-V-P5 -
Included Power Supply, 12
fault condition is removed
Protection type
Constant current limiting, recovers automatically after
VDC 6 Watt, 5MM Plug, International AC Input,
The product can be supplied with a DC power source ranging from 10
:
to 30
International AC Blades
PROTECTION
6.25 ~ 7.25V
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
VDC and features a barrel connector. A power supply is included.
DRAD35
- Optional DIN rail adapter clip (pair)
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Relay contact rating(max.): 30V/1A resistive
Ease of
FUNCTION DC OK SIGNAL
Use
Configuration, upgrades and monitoring of the serial server are simple, easy
"Derating Curve")
-20 ~ +70
(Refer to
WORKING TEMP.
tasks with Vlinx Manager Software. It installs on your PC giving access to
20 ~ 90% RH non-condensing
WORKING HUMIDITY
the serial server via your desktop. Remotely manage the Modbus Gateway
RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +85
, 10 ~ 95%
over a LAN or WAN via the build-in web server. This is
±
0.03%/
(0 ~ 50
)
helpful for off-site
TEMP. COEFFICIENT
troubleshooting and can be done with an ordinary web
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
browser.
VIBRATION
232NM9
- Optional mull modem crossover cable
Software Support
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY & WITHSTAND VOLTAGE
Windows XP (32/64 bit), 2003 Server (32/64 bit), Vista 32/64 bit), 2008 Server
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25
/ 70% RH
ISOLATION RESISTANCE
EMC
(32/64 bit), Windows 7 (32/64 bit), Windows 8 (32/64 bit), Windows 10 (32/64
(Note 4)
Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3
EMC EMISSION
bit).
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
SAFETY STANDARDS
UL508, UL60950-1, TUV EN60950-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 approved
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
299.2K hrs min. MIL-HDBK-217F (25
)
40*90*100mm (W*H*D)
0.33Kg; 42pcs/14.8Kg/0.82CUFT
OTHERS
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
All product specifications are subject to change without notice.
File Name:MDR-60-SPEC 2017-07-07
MESP211D & MESP211T_3617ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445

BB-MDR-60-12 Related Products

BB-MDR-60-12 BB-MDR-60-5
Description AC/DC CONVERTER 12V 60W AC/DC CONVERTER 5V 50W
type closed closed
Number of outputs 1 1
Voltage - input 85 ~ 264 VAC 85 ~ 264 VAC
Voltage - Output 1 12V 5V
Current - Output (maximum) 5A 10A
Power (W) 60W 50W
application ITE (Business) Hazardous Locations, ITE (Commercial)
Voltage - Isolation 3kV 3kV
efficiency 86% 78%
Operating temperature -20°C ~ 70°C (with derating) -20°C ~ 70°C (with derating)
characteristic Adjustable output, DC input capability, universal input Adjustable output, DC input capability, universal input
Installation type DIN rail DIN rail
size/dimensions 3.94" long x 1.57" wide x 3.54" high (100.0mm x 40mm x 90.0mm) 3.94" long x 1.57" wide x 3.54" high (100.0mm x 40.0mm x 90.0mm)
Approval CB,CE,cULus,TUVgs CB,CE,cULus,TUV
Thoughts after reading sunhong's post: How do you treat reference design?
I was also inspired by sunhong's post, so I hope everyone can discuss it. I remember that at this time last year, I interviewed a senior executive of NEC China, who is Chinese. Therefore, he inevitabl...
向农 Talking about work
After timer0 is turned on, tss=1 cannot be turned off. I want to turn off the timer now. Can you please help me?
[color=#000][font=Arial, Helvetica, sans-serif][size=12px] void delay(unsigned int x) { count=x; CpuTimer0Regs.TCR.bit.TSS=0; This is a delay program, using timer interrupt for delay. When delay is ca...
jonny0811 Microcontroller MCU
{STM32F429i development board} received and unharmed
I saw friends on the forum had broken cables, and I was worried for several days. I received it at noon today and opened the box immediately. Wow, lucky~~~ It came out intact. I guess the LCD cable is...
47857872 stm32/stm8
Supermarket CCTV Monitoring System Solution
I. System composition and distribution 1. Closed-circuit monitoring system In response to the requirements of a chain supermarket, the following supermarket closed-circuit television monitoring system...
呱呱 RF/Wirelessly
Newbie, please give me some advice!
I want to output num in half a clock cycle, using the following statement always@(posedge clk or posedge clk_re) num<=count; clk_re is the inverse signal of clk. There is a problem with the compilatio...
eeleader FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2164  687  73  9  1499  44  14  2  1  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号