60W Single Output Industrial DIN Rail Power Supply
■
Features :
Universal AC input/Full range
MDR-60
series
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Class I
,
Div 2 Hazardous Locations T4
LED indicator for power on
DC OK relay contact
No load power consumption<0.75W
www.advantech-bb.com
100% full load burn-in test
3 years warranty
..
Ultra Compact Modbus Gateways
Models MESP211D, MESP211T
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
™
MDR-60-5
5V
10A
0 ~ 10A
50W
5 ~ 6V
±1.0%
±1.5%
Note.5
500ms, 30ms/230VAC
PRODUCT FEATURES
MDR-60-12
MDR-60-24
24V
MDR-60-48
48V
RIPPLE & NOISE (max.)
Note.2
80mVp-p
VOLTAGE TOLERANCE
Note.3
±2.0%
•
•
•
•
•
Modbus TCP Ethernet, Modbus ASCII & RTU RS-232/422/485
5A
2.5A
1.25A
Modbus Flexibility – Serial & Ethernet, Masters & Slaves
0 ~ 5A
0 ~ 2.5A
0 ~ 1.25A
View Messaging Status in Real Time
60W
60W
60W
Ultra Compact IP30 Metal Enclosure
120mVp-p
150mVp-p
200mVp-p
International Power Supply (included
12 ~ 15V
±1.0%
±1.0%
±1.0%
24 ~ 30V
±1.0%
±1.0%
±1.0%
12V
48 ~ 56V
±1.0%
±1.0%
±1.0%
500ms, 30ms/115VAC at full load
ETHERNET ETHERNET
PORT
CONNECTOR
1
RJ45
1
Models MESP211D and MESP211T, Vlinx series Modbus Gateways, connect
HOLD UP TIME (Typ.)
50ms/230VAC
20ms/115VAC at full load
INFORMATION
ORDERING
Modbus devices to Ethernet networks and let you monitor
~
and control Modbus
370VDC
VOLTAGE RANGE
85 264VAC
120 ~
SERIAL
MODEL NUMBER PROTOCOL
PORT
devices from anywhere on the Ethernet LAN or WAN.
47 ~ 63Hz
up to 16
Supporting
FREQUENCY RANGE
MESP211D
RS-232/422/485 DB9 Male
masters and 32 slaves, these gateways feature an auto-detecting 10/100
EFFICIENCY (Typ.)
78%
86%
88%
MESP211T
RS-232/422/485 Removable
Ethernet
INPUT
RJ-45 port and a serial port that supports RS-232/422/485
copper
Terminal Block
AC CURRENT (Typ.)
1.8A/115VAC
1A/230VAC
communications via a DB9 male or a terminal block connection.
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START 30A/115VAC
<1mA / 240VAC
60A/230VAC
87%
RJ45
The product is built for use in industrial environments with a heavy-duty metal
ACCESSORIES
105 ~
enclosure that is panel (standard) or DIN rail mountable (with
150% rated output power
optional adapters).
OVERLOAD
SMI6-12-V-P5 -
Included Power Supply, 12
fault condition is removed
Protection type
Constant current limiting, recovers automatically after
VDC 6 Watt, 5MM Plug, International AC Input,
The product can be supplied with a DC power source ranging from 10
:
to 30
International AC Blades
PROTECTION
6.25 ~ 7.25V
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
VDC and features a barrel connector. A power supply is included.
DRAD35
- Optional DIN rail adapter clip (pair)
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Relay contact rating(max.): 30V/1A resistive
Ease of
FUNCTION DC OK SIGNAL
Use
Configuration, upgrades and monitoring of the serial server are simple, easy
"Derating Curve")
-20 ~ +70
℃
(Refer to
WORKING TEMP.
tasks with Vlinx Manager Software. It installs on your PC giving access to
20 ~ 90% RH non-condensing
WORKING HUMIDITY
the serial server via your desktop. Remotely manage the Modbus Gateway
RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +85
℃
, 10 ~ 95%
over a LAN or WAN via the build-in web server. This is
±
0.03%/
℃
(0 ~ 50
℃
)
helpful for off-site
TEMP. COEFFICIENT
troubleshooting and can be done with an ordinary web
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
browser.
VIBRATION
232NM9
- Optional mull modem crossover cable
Software Support
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY & WITHSTAND VOLTAGE
Windows XP (32/64 bit), 2003 Server (32/64 bit), Vista 32/64 bit), 2008 Server
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25
℃
/ 70% RH
ISOLATION RESISTANCE
EMC
(32/64 bit), Windows 7 (32/64 bit), Windows 8 (32/64 bit), Windows 10 (32/64
(Note 4)
Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3
EMC EMISSION
bit).
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
SAFETY STANDARDS
UL508, UL60950-1, TUV EN60950-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 approved
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
299.2K hrs min. MIL-HDBK-217F (25
℃
)
40*90*100mm (W*H*D)
0.33Kg; 42pcs/14.8Kg/0.82CUFT
OTHERS
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
All product specifications are subject to change without notice.
File Name:MDR-60-SPEC 2017-07-07
MESP211D & MESP211T_3617ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
60W Single Output Industrial DIN Rail Power Supply
Mechanical Specification
35
40
5 5 5 5 5
MDR-60
Case No.962A
100
series
Unit:mm
Ultra Compact Modbus Gateways
Models MESP211D, MESP211T
+V +V -V -V
DC OK
DC OK
+
90
+V ADJ
www.advantech-bb.com
Install DIN rail TS35/7.5 or TS35/15
•
•
•
7.5 7.5
•
•
N
L
PRODUCT FEATURES
Modbus TCP Ethernet, Modbus ASCII & RTU RS-232/422/485
Modbus Flexibility – Serial & Ethernet, Masters & Slaves
View Messaging Status in Real Time
Ultra Compact IP30 Metal Enclosure
International Power Supply (included
Block Diagram
fosc : 60KHz
DC OK
Models MESP211D and MESP211T, Vlinx series Modbus Gateways, connect
Modbus devices to Ethernet networks and let you monitor and control Modbus
RECTIFIERS
EMI
devices from anywhere on the Ethernet LAN or WAN. Supporting up to 16
I/P
&
FILTER
masters and 32 slaves, these gateways feature an auto-detecting 10/100
FILTER
Ethernet copper RJ-45 port and a serial port that supports RS-232/422/485
communications via a DB9 male or a terminal block connection.
™
ORDERING INFORMATION
MODEL NUMBER
POWER
MESP211D
SWITCHING
MESP211T
SERIAL
RECTIFIERS
PORT
&
RS-232/422/485 DB9 Male
FILTER
RS-232/422/485 Removable
Terminal Block
PROTOCOL
DETECTION
CIRCUIT
ETHERNET ETHERNET
PORT
CONNECTOR
+V
1
RJ45
-V
1
O.C.P.
RJ45
The product is built for use in industrial environments with a heavy-duty metal
O.L.P.
enclosure that is panel (standard) or DIN rail mountable (with optional adapters).
The product can be supplied with a DC power source ranging from 10 to 30
VDC and features
OK Relay Contact
supply is included.
DC
a barrel connector. A power
Ease of Use
Contact Close
PSU turns on / DC OK.
Configuration, upgrades and monitoring
PSU turns off
server are simple, easy
of the serial
/ DC Fail.
Contact Open
tasks with Vlinx
Contact Ratings (max.)
installs on
resistive load.
access to
Manager Software. It
30V/1A
your PC giving
the serial server via your desktop. Remotely manage the Modbus Gateway
over a LAN or WAN via the build-in web server. This is helpful for off-site
Derating Curve
troubleshooting and can be done with an ordinary web browser.
Software Support
Windows XP (32/64 bit), 2003 Server (32/64 bit), Vista 32/64 bit), 2008 Server
100
12V,24V,48V
(32/64 bit), Windows 7 (32/64 bit), Windows 8 (32/64 bit), Windows 10 (32/64
bit).
80
60
FG
CONTROL
ACCESSORIES
SMI6-12-V-P5 -
Included Power Supply, 12 VDC 6 Watt, 5MM Plug, International AC Input,
O.V.P.
International AC Blades
DRAD35
- Optional DIN rail adapter clip (pair)
232NM9
- Optional mull modem crossover cable
Output Derating VS Input Voltage
100
90
80
70
LOAD (%)
LOAD (%)
60
70 (VERTICAL)
50
40
5V
60
50
40
20
-20
0
10
20
30
45
55
85
95
100
115
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE (
℃
)
INPUT VOLTAGE (VAC) 60Hz
All product specifications are subject to change without notice.
File Name:MDR-60-SPEC 2017-07-07
MESP211D & MESP211T_3617ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445