Photoelectrics
Diffuse-reflective
Type PD30CND10....DU
•
•
•
•
•
•
•
•
•
•
•
•
Miniature sensor range
Range: 1 m
Sensitivity adjustment by Teach-In programming
Modulated, red light 660 nm
Supply voltage: 10 to 30 VDC
Output: 100 mA, NPN or PNP preset
Make or break switching function programmable
LED indication for output, stability and power ON
Protection: reverse polarity, short circuit and transients
Cable and plug versions
Excellent EMC performance
Dust alarm output
Product Description
The PD30CND10 sensor
family comes in a compact
10 x 30 x 20 mm reinforced
PMMA/ABS housing. The
sensors are useful in appli-
cations where high accuracy
detection as well as small
size is required. Compact
housing and high power
LED for excellent perfor-
mance-size ratio.
The Teach-In function for
adjustment of the sensitivi-
ty makes the sensors highly
flexible. The output type is
preset (NPN or PNP), and
the output switching function
is one NO or NC output and
one dust output NO or NC.
Ordering Key
Type
Housing style
Housing size
Housing material
Housing length
Detection principle
Sensing distance
Output type
Output configuration
Connection type
Dust Output
PD30CND10PPM5DU
Type Selection
Housing
WxHxD
Range
S
n
Connection
Ordering no.
NPN
Make and break switching
PD 30 CND 10 NPDU
PD 30 CND 10 NPM5DU
Ordering no.
PNP
Make and break switching
PD 30 CND 10 PPDU
PD 30 CND 10 PPM5DU
10 x 30 x 20 mm
10 x 30 x 20 mm
1m
1m
Cable
Plug
Specifications
EN 60947-5-2
Protection
Light source
Light type
Sensing angle
Ambient light
Light spot
Operating frequency
(f)
Response time
OFF-ON (t
ON
)
ON-OFF (t
OFF
)
Power ON delay
(t
v
)
Output function
NPN and PNP
Output configuration
Programming options
Output pin 4 black
Output pin 2 white
Dust alarm output
Delay on operate
Short-circuit, reverse polarity
and transients
GaAlAs, LED, 660 nm
Red, modulated
± 2º
10,000 lux
110 mm @ 1.5 m
≤ 1000 Hz
≤ 0.5 ms
≤ 0.5 ms
≤ 300 ms
Preset
NO or NC
NO or NC
NO or NC (dust)
20 ms
Rated operating distance
(S
n
) Up to 1 m,
reference target Kodak test
card R27, white, 90%
reflective, 200 x 200 mm
Blind zone
≤ 20 mm
Sensitivity
Adjustable by Teach-In
Temperature drift
≤ 0.1%/ºC
Hysteresis
(H)
(differential travel)
≤ 10%
Rated operational volt.
(U
B
)
10 to 30 VDC
(ripple included)
Ripple
(U
rpp
)
≤ 10%
Output current
Continuous (I
e
)
≤ 100 mA
Short-time (I)
≤ 100 mA
(max. load capacity 100 nF)
No load supply current
(I
o
)
≤ 30 mA @ 24 VDC
Minimum operational current
(I
m
) ≤ 0.5 mA
OFF-state current
(I
r
)
≤ 100 µA
Voltage drop
(U
d
)
≤ 2.4 VDC @ 100 mA
Specifications are subject to change without notice (05.07.2016)
1
PD30CND10....DU
Specifications (cont.)
Indication
Output ON
Signal stability ON and
Power ON
Environment
Installation category
Pollution degree
Degree of protection
Ambient temperature
Operating
Storage
Vibration
Shock
EN 60947-5-2
Rated insulation voltage
Housing material
Body
Frontglas
Connection
Cable
Plug
Weight
Cable version
Plug version
CE-marking
Approvals
≤ 500 VAC (rms)
ABS
PMMA Red
PVC, black, 2 m
4 x 0.14 mm
2
, Ø = 3.3 mm
M8, 4-pin (CON. 54-series)
≤ 40 g
≤ 10 g
Yes
cULus (UL508 + CSA)
LED, yellow
LED, green
III (IEC 60664/60664A;
60947-1)
3 (IEC 60664/60664A;
60947-1)
IP 67 (IEC 60529; 60947-1)
-25° to +60°C (-13° to +140°F)
-40° to +70°C (-40° to +158°F)
10 to 55 Hz, 0.5 mm/7.5 g
(IEC 60068-2-6)
30 g / 11ms, 3 pos, 3 neg
per axis
(IEC 60068-2-6, 60068-2-32)
Operation Diagram
Tv = Power ON delay
Power supply
Object
Break Output (N.C.)
Make Output (N.O.)
ON
OFF
Present
Not Present
Tv
ON
OFF
ON
OFF
Tv
Wiring Diagrams
NPN
1 BN
2 WH*
4 BK
3 BU
*Dust Output
GND
3 BU
*Dust Output
GND
V
PNP
1 BN
4 BK
2 WH*
V
Detection Diagram
Excess Gain
1,000
40
30
Exess gain
0
200
400
600
800
1000
1200
1400
20
10
(mm)
0
-10
-20
-30
-40
100
10
1
10
100
Distance (mm)
1,000
10,000
Distance (mm)
2
Specifications are subject to change without notice (05.07.2016)
PD30CND10....DU
Signal Stability Indication
Accessories
21.2
14
9°
1.2
3.2
32.4
25.4
1.2
Excess Gain
1.25
1.0
0.75
Operation level x 1.25
Operation level
Operation level x 0.75
10
25.4
39
13.5
26,3
16.2
6.0
6.0
5.2
Time
7.3
5.7
10
16
8.2
4.4
Green LED ON
Yellow LED ON
Dust ON
4.4
4.4
Mounting bracket: APD30-1
Mounting bracket: APD30-2
Dimensions
Cable version
Teach Button
6
10.6
20
20
10.6
6
Plug version
Teach Button
Output LED
Yellow
PD30CNP
06NPM5T
10-30 V
100 mA
BN: V+
UL
BU: V-
BK: OUT
WH: ET
Power / Stability LED
Green
10.6
Output LED
Yellow
10.6
17
Receiver
Optical axis
10.8
PD30CNP
06NPM5T
10-30 V
100 mA
BN: V+
UL
BU: V-
BK: OUT
WH: ET
R
Power / Stability LED
Green
1.1
R
Receiver
Optical axis
Two, 9.5 dia.
Lenses
1.1
17
10.8
Two, 9.5 dia.
Lenses
xxxxxxS
25.4
30
5.5 5.5
15
5.5 5.5
Incorrect
22
xxxxxxS
25.4
30
Correct
22
Two M3
Emitter
Two M3
> 100 mm
10.25
Emitter
Installation Hints
To avoid interference from inductive voltage / Relief of the cable strain
current peaks, separate the proximity switch
cables from any other power cables. E.g.
Engine, contactor or solenoid cables
Protection of the sensing face
Sensor mounted on a mobile carrier
Incorrect
Incorrect
Incorrect
Correct
Correct
> 100 mm
The cable should not be pulled
A proximity switch should not serve
as mechanical stop
Any repetitive flexing of the
cable should be avoided
Delivery Contents
•
Photoelectric switch: PD 30 CND 10 ...
• Installation instruction
• Mounting bracket APD30-MB1
•
Packaging:
Cardboard box
Specifications are subject to change without notice (05.07.2016)
Accessories
•
Mounting bracket APD30-MB1 or APD30-MB2 to be
purchased separately.
15
14
3
29.3
3.2
9°
3
PD30CND10....DU
Teach functions
Normal operation, optimized switching point.
1. Line up the sensor at the background. Yellow LED is
OFF and Green LED is ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Place the object in the detection zone.
4. Press the button once and the sensor is ready to
operate (Green LED ON, Yellow LED ON)
(The second switch point is stored)
For dynamic set-up (running process)
1. Line up the sensor at the object. Green LED is ON,
status on the yellow LED is not important.
2. Press the button for 3 second until both LEDs flashes
simultaneously.
3. Press the button a second time for at least one
second, both LED’s flashes fast simultaneously and
keep the button pressed for at least one process
cycle, release the button and the sensor is ready to
operate (The second switch point is stored)
1
2
3
4
1
2
3
3 sec.
Push once
3 sec.
One cycle
For maximum sensing distance
(default setting)
1. Line up the sensor at the background. Yellow LED is
OFF and Green LED is ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Press the button a second time and the sensor is
ready to operate (Green LED ON, Yellow LED ON)
(The second switch point is stored)
For make or break set-up (N.O. or N.C.)
1. Press the button for 10 seconds, until the green LEDs
flashes.
2. While the green LED flashes, the output is inverted
each time the button is pressed. Yellow LED indicates
N.O. function selected.
If the button is not pressed within the next 10
seconds, the current output is stored.
1
2
1
2
3
10 sec.
3 sec.
Push once
Push once
For minimum detection overhead.
1. Line up the sensor at the object. Yellow LED is ON
and Green LED is ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Press the button a second time and the sensor is
ready to operate(Green LED ON, Yellow LED ON)
(The second switch point is stored)
For dust output (N.O. or N.C.)
1. Press the button for 15 seconds, until the yellow LEDs
flashes.
2. While the yellow LED flashes, the dust output is
inverted each time the button is pressed. Green LED
indicates N.O. function selected.
If the button is not pressed within the next 10
seconds, the current output is stored.
1
2
1
2
3
15 sec.
Push once
3 sec.
4
Push once