%URDGEDQG 2SWLPL]HG 6,'$&WRU
'HYLFH
RoHS
¨
The DO-214AA
SIDACtor Broadband Optimized
protection devices are intended for
applications sensitive to load values. Typically, high speed connections require a lower
capacitance. C
O
values are 40% lower than standard devices.
SIDACtor
devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
P0642S_L
P0722S_L
P0902S_L
P1102S_L
P1302S_L
P1502S_L
P1802S_L
P2302S_L
P2602S_L
P3002S_L
P3502S_L
P4202S_L
P4802S_L
P6002S_L
V
DRM
Volts
58
65
75
90
120
140
170
190
220
280
320
190
440
275
V
S
Volts
77
88
98
130
160
180
220
260
300
360
400
250
600
350
V
T
Volts
4
4
4
4
4
4
4
4
4
4
4
8
4
8
I
DRM
μAmps
5
5
5
5
5
5
5
5
5
5
5
5
5
5
I
S
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
800
800
I
T
Amps
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
I
H
mAmps
120
120
120
120
120
120
120
120
120
120
120
120
120
120
*
“L” in part number indicates RoHS compliance.
For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
• I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
• Listed
SIDACtor
devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• V
DRM
is measured at I
DRM.
• V
S
is measured at 100 V/μs.
• Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
Surge
Ratings in Amps
I
PP
Series
0.2x310 * 2x10 *
8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
Amps
A
B
20
25
Amps
150
250
Amps
150
250
10x160 *
10x160 **
Amps
90
150
10x560 *
10x560 **
Amps
50
100
5x320
*
9x720 **
Amps
75
100
I
TSM
10x360 * 10x1000 *
5x310
*
50
/ 60 Hz
di/dt
10x360 ** 10x1000 ** 10x700 **
Amps
Amps/μs
Amps
75
125
Amps
45
80
Amps
75
100
Amps
20
30
Amps
500
500
* Current waveform in μs
** Voltage waveform in μs
www.littelfuse.com
3 - 16
© 2006 Littelfuse, Inc. • Telecom Design Guide
%URDGEDQG 2SWLPL]HG 6,'$&WRU 'HYLFH
Thermal Considerations
Package
DO-214AA
Symbol
T
J
T
S
R
θJA
Parameter
Operating Junction Temperature Range
Storage Temperature Range
Thermal Resistance: Junction to Ambient
Value
-40 to +150
-65 to +150
90
Unit
°C
°C
°C/W
Capacitance Values
pF
Part Number *
P0642S[A/B]L
P0722S[A/B]L
P0902S[A/B]L
P1102S[A/B]L
P1302S[A/B]L
P1502S[A/B]L
P1802S[A/B]L
P2302S[A/B]L
P2602S[A/B]L
P3002S[A/B]L
P3502S[A/B]L
P4202S[A/B]L
P4802S[A/B]L
P6002S[A/B]L
MIN
25
20
20
15
15
15
10
10
10
10
10
10
5
5
MAX
45
45
40
35
35
30
30
25
25
25
20
20
20
20
* [A/B] in part number indicates that values are for both A and B surge ratings.
Note: Off-state capacitance (C
O
) is measured at 1 MHz with a 2 V bias.
Telecom Design Guide • © 2006 Littelfuse, Inc.