Conductors: 30 AWG 7 X 38 [ 7 X 0.102 ] Tinned Stranded Copper
Marking:
Material: Polyvinyl Chloride (PVC)
Color: Gray
Electrical
Voltage Rating:
USA: 30V
Insulation Resistance:
>1 x 10
10
Ω
/10 ft [3 m]
Characteristic Impedance:
Unbalanced
73
Ω
Capacitance:
20.8 pF/ft (68.2 pF/m)
Inductance:
.11 μH/ft (0.36 μH/m)
EU: <50V
Balanced
122
Ω
12.0 pF/ft (39.4 pF/m)
1.45 ns/ft (4.76 ns/m)
Propagation Delay:
1.51 ns/ft (4.95 ns/m)
Velocity of Propagation:
67%
.18 μH/ft (0.59 μH/m)
70%
Note: Unbalanced is measured between ground-signal-ground conductors. Balanced is measured between signal conductors within a pair.
Environmental
Temperature Rating:
-20°C to +105°C
Flammability Rating:
USA:VW-1
UL File No.: E42769, Style No.: 20596
3
Electronic Solutions Division
Interconnect Solutions
http://www.3Mconnectors.com
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
3M
™
Round Conductor Flat Cable
.025" 30 AWG Stranded, PVC
Number of
Conductors
10
12
14
16
Inch
[mm]
Tolerance Unless Noted
.0
Inch
±.1
.00
±.01
.000
±.005
20
26
30
32
34
36
40
50
52
60
68
80
100
3M Part
Number
3754/10
3754/12
3754/14
3754/16
3754/20
3754/26
3754/30
3754/32
3754/34
3754/36
3754/40
3754/50
3754/52
3754/60
3754/68
3754/80
3754/100
Dimension A
0.250 ± .006 [ 6.350 ]
0.300 ± .006 [7.62]
0.350 ± .006 [8.89]
0.400 ± .006 [10.16]
0.500 ± .006 [ 12.70 ]
0.650 ± .006 [ 16.51 ]
0.750 ± .006 [ 19.05 ]
0.800 ± .008 [ 20.32 ]
0.850 ± .009 [ 21.59 ]
0.900 ± .009 [ 22.86 ]
1.000 ± .009 [ 25.40 ]
1.250 ± .009 [ 31.75 ]
1.300 ± .009 [ 33.02 ]
1.500 ± .012 [ 38.10 ]
1.700 ± .012 [ 43.18 ]
2.000 ± .015 [ 50.80 ]
2.500 ± .015 [ 63.50 ]
A
B
.013
±
.005
[ 0.33 ]
.025
±
.002 Typ
[ 0.64 ]
3754 Series
Dimension B
0.225 ± .004 [5.72 ]
0.275 ± .004 [6.99]
0.325 ± .004 [8.26]
0.375 ± .004 [9.53]
0.475 ± .004 [ 12.07 ]
0.625 ± .004 [ 15.88 ]
0.725 ± .006 [ 18.42 ]
0.775 ± .006 [ 19.69 ]
0.825 ± .006 [ 20.96 ]
0.875 ± .006 [ 22.23 ]
0.975 ± .006 [ 24.77 ]
1.225 ± .006 [ 31.12 ]
1.275 ± .006 [ 32.39 ]
1.475 ± .009 [ 37.47 ]
1.675 ± .009 [ 42.55 ]
1.975 ± .011 [ 50.17 ]
2.475 ± .012 [ 62.87 ]
[ ] Dimensions for Reference Only
.025
±
.003
[ 0.64 ]
30 AWG 7 X 38 ( 7 X 0.102 ) Tinned
Stranded Copper Conductors
PVC Insulation
Note: Red marking on one edge of cable designates wire #1.
Ordering Information
3754/XX
Number of Conductors
(See Table)
Note: Available in standard 100 ft or 300 ft rolls, please specify
when ordering. Contact 3M for availability of additional conductor
counts and/or custom roll lengths.
TS-0875-E
Sheet 2 of 3
3
Electronic Solutions Division
Interconnect Solutions
http://www.3Mconnectors.com
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
Important Notice
All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the accuracy or completeness
is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated
with such use. Any statements related to the product which are not contained in 3M’s current publications, or any contrary statements contained on your purchase order
shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase.
3M MAKES NO OTHER WARRANTIES
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
If this product is defective within the
warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product.
Except
where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of
I want to make a program list recently, that is, to display a list of all currently running applications (not processes), but I don't know how to get it. Is there a direct way to get it? I know how to...
I want to display temperature and humidity, and alarm when the temperature is greater than 28. Now the temperature and humidity cannot be displayed. Please help me find out what's going on. Thank you/...
I have been trying to adjust LPC2138CS5530 for more than a week, but it doesn't work. All I get back is 0xFF, what's going on? ? Does anyone have an example of how LPC2138 can communicate with CS5530 ...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Common Mode Semiconductor has officially released its latest generation of power management ICs—the GM6506 series. This fully integrated high-frequency synchronous rectification step-down p...[Details]
With the rapid development of electric vehicles in my country, people are beginning to pay attention to the issue of radiation from electric vehicles. We all know that mobile phones emit radiation,...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
My career has been closely tied to the semiconductor industry. From product management to content marketing, I've provided countless forecasts and predictions across a variety of roles. Whethe...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]
Preface
Low-voltage motors are widely used in nonferrous metallurgical plants. Their abnormal operation not only impacts normal production but can also threaten human life. Therefore, providin...[Details]
From time to time, I see some audiophiles spending a lot of money or a lot of time to DIY speakers, but the results are not what they want. Below I list some of the small experiences I summarized b...[Details]
introduction
In today's busy society, people experience chronic high stress, which in turn poses a significant threat to our health. Therefore, effectively relieving stress has become a pr...[Details]
0 Introduction
DVI (Digital Visual Interface) is a hot topic in current digital display research and application. Video processing technologies for DVI output not only address issues such as h...[Details]
In this final installment of a five-part blog series, I will discuss noise in op amps driving headphone loads and some techniques for reducing it. Previous posts have discussed headphone load power...[Details]
The intelligent
dust monitoring system intelligently monitors dust concentrations at and around construction sites. All concentration values are transmitted to a cloud server for
cloud co...[Details]
The primary control objective in this case is the display and alarming of data parameters on the Xinheng control scale instrument. The system's main PLC uses a Siemens CPU, and data is collected vi...[Details]