EEWORLDEEWORLDEEWORLD

Part Number

Search

M-21

Description
CONN BARRIER STRIP 21CIRC 0.5"
CategoryThe connector   
File Size127KB,2 Pages
ManufacturerCurtis Industries
Environmental Compliance
Download Datasheet Parametric View All

M-21 Overview

CONN BARRIER STRIP 21CIRC 0.5"

M-21 Parametric

Parameter NameAttribute value
Terminal block typebarrier block
Number of circuits21
Number of incoming lines42
spacing0.500"(12.70mm)
Number of rows2
Rated current15A
Rated voltage-
Wire gauge14-22 AWG
top terminationscrews
bottom terminationclosed
Partition typeDouble wall (double)
characteristicflange
color-
Terminal thread materialsteel
Terminal thread surface-
Installation typebase, panel
Operating temperature150°C
Material - InsulationPhenolic resin (phenolic resin)
Material flammability ratingUL94 V-0
Series M
.5" (12.7mm) Center-to-Center Spacing
Features:
Compact Modular Design for Low Power Circuits
Suitable for surface connection applications using channel-
assembled modular construction.
All-Surface Mountability
– Requires no additional
insulation. Electro tin-coated steel mounting channel has
two .196" diameter mounting holes.
Thermo-Set Phenolic Barrier-Type Terminal Blocks
One thru 24 terminals on 1/2" center-to-center spacing.
Broad Choice of Terminal Connections
– Available in
three screw designs and two .250" wide quick-connect
variations offering up to four connections per terminal.
Wire Sizes
– M Series (No. 6-32 screw) is UL recognized
for No. 22AWG to No. 14AWG. MA Series (No. 8-32 screw)
is UL recognized for No. 22AWG to No. 12AWG. CSA
requires lugs on wire larger than No. 14AWG for Series MA,
and CSA requires lugs on No. 16AWG for Series M.
Current/Voltage Rating
– MA Series 25A/300V, M Series
15A/300V
Recognition and Listing
– Various terminal types are UL
recognized and CSA certified.
Dual Row
TERMINAL DESIGNATIONS
*MA
BARRIER STYLE
Series M Variations
MA
terminal bar with two
No. 8-32 screws
MAQ
four .250" side
quick-connects
16-gauge (.051") brass terminal bar with two No.
8-32 plated steel screws per terminal accepting wire
up to No. 12AWG
*MAQ
Four .250" x .032" brass quick-connect tabs per
terminal accepting wire up to No. 12AWG
*MALQ
Two .250" x .032" brass quick-connect tabs and one
No. 8-32 plated steel screw per terminal accepting
wire up to No. 12AWG. Rated 25A/300V
*M
Brass terminal bar with two No. 6-32 plated steel
screws per terminal accepting wire up to No. 14AWG
*MC
Brass terminal bar with two-piece No. 6-32 plated
steel, capitvated clamp assemblies per terminal
accepting wire up to No. 14AWG
Recognized under the Components Program of
Underwriters Laboratories, Inc. Standard 1059,
Guide No. XCFR2, File No. E62557.
Guide No. 22.2 No. 158, Report No. LR39186-1.
MALQ
two .250" wide quick-
connects and one
No. 8-32 screw
M
terminal bar with two No.
6-32 screws
MC
terminal bar with two
captivated clamp assembles
34
www.curtisind.com
Curtis Industries
A Division of Powers Holdings, Inc.
ci c tions su ct to c n .
Dimensions are shown for
reference purposes only.
Listview sorting problem in vs2003 smart device
I am currently doing wince development and using vs2003, but the listview control in 2003 does not have a sorting function. I want to expand it and hope that experts can give me some advice....
fewcome Embedded System
Atmega16 lock solution sharing
Today, I accidentally set the fuse bit wrong, which caused the program to fail to download. Later, I added the ALE pin of the 51 microcontroller directly to the XTAL1 of the ATMEGA16, but it didn’t wo...
fan740602 Microchip MCU
FlexRay communication control of steer-by-wire based on μC/OS-Ⅱ
[b]0 Introduction[/b] In recent years, with the continuous development of the automobile industry and the electronics industry, automobile steer-by-wire technology has become a hot topic of research, ...
yuandayuan6999 MCU
[TI's first low-power design competition] The board I made has arrived
This is the board based on the schematic diagramThe company has been busy recently! The board has arrived, just a quick comment:...
ddllxxrr Microcontroller MCU
Looking for part-time electronic technology developers
I have a small project to collect weak electrical signals from the human body, amplify and filter interference signals, and analyze and feedback the collected signals. If you have experience in this a...
benin Recruitment
Has anyone used the SQL Server database in WINCE Lite?
As the title says. If you have used it, what do you think? Is it necessary to use it? Do you have any suggestions?...
haitao664 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1915  2027  1583  2497  2506  39  41  32  51  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号