EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS240PAF36/L

Description
AC/DC CONVERTER 36V 240W
CategoryPower/power management    The power supply circuit   
File Size535KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS240PAF36/L Overview

AC/DC CONVERTER 36V 240W

ZWS240PAF36/L Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTDK-LAMBDA
Reach Compliance Codecompliant
Is SamacsysN
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
CertificationCE, UL
Efficiency (main output)82%
high42 mm
Maximum input voltage265 V
Minimum input voltage85 V
length222 mm
Maximum grid adjustment rate0.4%
Maximum load regulation0.8%
Maximum operating temperature70 °C
Minimum operating temperature-10 °C
Maximum output current6.7 A
Nominal output voltage36 V
ProtectOUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
Maximum total power output241.2 W
width95 mm
Base Number Matches1
ZWS-AF Series
50W to 150W Single Output Low Cost, Worldwide Use
Features
u
Universal Input (85 - 265VAC)
u
Power factor Corrected
u
Input transient protected
u
2 year warranty
u
High quality design
u
Peak Power capability
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range
DC Input Voltage range
Input Current (Typ) (1)
Inrush Current
Power Factor (1)
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection (4)
Hold Up Time (Typ) (1)
Leakage Current
Remote On / Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
ZWS75AF
ZWS100AF
ZWS150AF
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3 & 5V: 120mV; 12 to 24V: 150mV; 36 & 48V: 200mV
<0.02%/°C
>105% of Peak Current Capability
20ms
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
Two Years
ZWS50AF
Notes:
(1) 100/200VAC
(2) ZWS150AF -10 to 60°C, derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
For New Designs, See ZWSBAF Series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
1
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Capacitance-to-Digital Converter AD7747 Test Code
The AD7747 is a high-resolution, Σ-Δ capacitance-to-digital converter (CDC). The capacitance to be measured can be connected directly to the device input. The architecture also has inherent characteri...
littleshrimp Sensor
API Function Introduction
[i=s] This post was last edited by paulhyde on 2014-9-15 09:13 [/i] Friends who are learning to use the LM3S811 development board: If you have difficulty programming, take a look at these function int...
非雪之悠 Electronics Design Contest
Byte-Program Operation Problems of SST39VF Series
Do I need to write a three-byte-load command sequence every time before writing a number to an address? And then I need to wait for data#polling or toggle bit to confirm that the data is programmed? I...
hehewyx Embedded System
DC servo motor driver is still very good
...
led2015 Motor Drive Control(Motor Control)
The 4.3-inch screen is finally done
After a Spring Festival preparation, and buying a few other people's boards for reference, I finally lit up the 4.3-inch screen. The control part of this board is the STM32 chip, and then the dedicate...
fsyicheng FPGA/CPLD
Please tell me about MDD/PDD
Experts, I am not very clear about MS's MDD/PDD. Since it is a layered driver, are there any interface definitions for the MDD layer and the interface definitions for the PDD layer? Where are those in...
游客 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2091  2600  208  2464  185  43  53  5  50  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号