ULTIPLE PRESSURE RANGES AVAILABLE TO MEASURE PRESSURE DOWN TO
0.15 PSI
FULL
-
SCALE
AND UP TO
100
PSI
FULL
-
SCALE
DESCRIPTION
The Silicon Microstructures
SM5812
and
SM5852
series of OEM pressure sensors
combines state-of-the-art pressure sensor
technology with CMOS digital signal
processing technology to produce an
amplified, fully conditioned, multi-order
pressure and temperature compensated
sensor in a dual in-line package (DIP)
configuration.
Combining the pressure sensor with a
custom signal conditioning ASIC in a single
package simplifies the use of advanced
silicon micromachined pressure sensors.
Now, the pressure sensor can be mounted
directly to a standard printed circuit board
and an amplified, high level, calibrated
pressure signal can be acquired from the
digital interface or analog output. This
eliminates the need of additional circuitry,
such as a compensation network or micro-
controller containing a custom correction
algorithm.
The
SM5812/SM5852
Series pressure
sensors are based on SMI's highly stable,
piezoresistive pressure sensor chips
mounted on a ceramic substrate. An
electronically programmable ASIC is
contained in the same package to provide
calibration and temperature compensation.
The model
SM5812
is designed for
operating pressure ranges from 0-5 PSI up
to 0-100 PSI. The model
SM5852
is
designed for operating pressure ranges from
0-0.15 PSI up to 0-3 PSI. For both models,
the sensor output is ratiometric with the
supply voltage.
FEATURES
•
•
•
•
•
•
•
Amplified, calibrated, fully signal
conditioned output span of 4.0 VDC FS
(0.5 to 4.5 V signal)
Digital temperature and calibrated
2
pressure available through I C interface
Output ratiometric with supply voltage
Multi-order correction for pressure non-
linearity (factory programmed)
Multi-order correction for temperature
coefficient of span and offset (factory
programmed)
Gage, differential, and absolute versions
SMI’s unique low-pressure die allows for
a full-scale pressure range of 0-0.15 PSI
Barometric measurement
Medical instrumentation
Pneumatic control
Gas flow
Respirators and ventilators
Heating, Ventilation and Air Conditioning
(HVAC)
TYPICAL APPLICATIONS
•
•
•
•
•
•
Rev 1.4 6_05
2005 SMI
Silicon Microstructures, Inc.
♦
1701 McCarthy Blvd.
♦
Milpitas, CA 95035
♦
USA
Tel: 408-577-0100
♦
Fax: 408-577-0123
♦
Sales@si-micro.com
♦
www.si-micro.com
SM5812/SM5852
THEORY OF OPERATION
The operation of the signal processor is
depicted in the block diagram below. The
external pressure sensor is a piezoresistive
bridge. This transduces the applied pressure
into an electronic signal, which is then inputted
into the integrating amplifier of the ASIC.
During the amplification step an offset
correction factor is added in order to allow
maximum gain for a given pressure while
minimizing the offset error.
The signal is then passed to an 11-bit analog
to digital converter (ADC). The ADC samples
the signal multiple times and uses the sum of
those samples as a 13-bit word.
A digital signal processor (DSP) is then used
to correct and calibrate the pressure signal.
The DSP provides multi-order correction of
both pressure and temperature non-linearity
through the use of factory-programmed
coefficients. A combined total of twenty
SMI Multi-Order Pressure and
Temperature Correction ASIC
coefficients are available for correcting
pressure and temperature non-linearity. The
unique coefficients are determined during a
calibration process performed at the factory.
Factory calibration is the last step performed
which means the effect of the package on
the pressure signal will also be taken into
account. This provides a great advantage
over conventional laser-trimming
approaches.
The DSP outputs a corrected digital word,
which travels to a 12-bit digital to analog
converter (DAC) to provide a calibrated
analog output. In addition to the analog
output, the corrected pressure signal is
2
accessible through an I C digital interface.
See SMI application note AN05-001 for a
detailed description of how to read out the
digital corrected pressure signal using the
I2C bus interface.
+ 5 VDC
+ 5 VDC
Band-gap
External
Piezoresistive
Bridge
V
Temp
DSP
(multi-order
correction of
pressure and
temperature
non-
linearities)
Ground
Switched
Capacitor
Integrateing
Amplifier
MUX
11-bit ADC
12-bit
Sigma-
Delta DAC
Power-On
Reset
Analog
Timing
Control
EEPROM
Array
Output
Buffer
Analog
Output
2 MHz
Oscillator
Digital Timing
and Control
Management
I
2
C Digital
Interface
SDA
SCL
Analog Component
Ground
Digital Component
Rev 1.4 6_05
2005 SMI
Silicon Microstructures, Inc.
♦
1701 McCarthy Blvd.
♦
Milpitas, CA 95035
♦
USA
Tel: 408-577-0100
♦
Fax: 408-577-0123
♦
Sales@si-micro.com
♦
www.si-micro.com
SILICON
MICROSTRUCTURES
INCORPORATED
SM5812/SM5852
CHARACTERISTICS FOR SM5812/SM5852 –
SPECIFICATIONS
All parameters are measured at room temperature while applying 5.000V supply, unless otherwise specified.
Absolute , Gage & Single
MIN
Zero output (absolute and gauge)
Zero output (differential)
Output Span
0.15 PSI
Linearity
0.15 PSI
Pressure hysteresis
5812
5852
Temperature coefficient - Zero
0.15 PSI
Temperature coefficient – Span
0.15 PSI
Thermal hysteresis
Response Time
Supply voltage
Current consumption
Overpressure
Operating temperature range
Compensated temperature range
Storage temperature range
Media compatibility
Weight
Notes:
1.
2.
3.
4.
Absolute parts are only offered in the SM5812 Series.
Single-ended parts (Pressure Type - S) have 2 ports and are for higher gain differential applications where the
differential pressure is
always
positive.
Sensor output is ratiometric to supply.
Full-scale (FS) is defined as zero pressure to rated pressure; differential parts can be used ±FS. Absolute and Gauge
zero output is 0.5 V typical and full-scale output is 4.5 V. Span is the difference between Full-scale output and zero
output, (4 V). For Differential parts, the negative full-scale is typically at 0.5 V, zero is typically 2.5 V, and positive full-
scale is 4.5 volts to give a span of
±2.0
V.
Defined as best fit straight line for positive pressure applied to the part
Or 225 PSI, whichever is less. Output amplifier will saturate at about 0.25 V for applied pressure below the rated Zero
and at about 4.75 V for applied pressure above the rated Full-scale.
A 100 nF filter capacitor must be placed between Vsupply and Ground.
Clean, dry gas compatible with wetted materials. Wetted materials include Pyrex glass, silicon, alumina ceramic, epoxy,
RTV, gold, aluminum, and nickel.
3
3
gram
5812
5852
3X
15X
-40
0
-55
25
25
25
+125
+70
+135
3.92
3.80
-0.5
-2.5
-0.1
-0.3
-1.0
-2.5
-1.0
-2.0
-0.1
2
4.75
5.00
5.25
10
3X
15X
-40
0
-55
25
25
25
+125
+70
+135
4.00
4.00
4.08
4.20
+0.5
+2.5
+0.1
+0.3
+1.0
+2.5
+1.0
+2.0
+0.1
0.42
TYP
0.50
MAX
0.58
2.42
1.96
1.90
-0.5
-2.5
-0.1
-0.3
-1.0
-2.5
-1.0
-2.0
-0.1
2
4.75
5.00
5.25
10
2.50
2.00
2.00
2.58
2.04
2.10
+0.5
+2.5
+0.1
+0.3
+1.0
+2.5
+1.0
+2.0
+0.1
1
2
Differential
MIN
TYP
MAX
UNITS
V
V
V FS
V FS
%FS
%FS
%FS
%FS
%FS
%FS
%FS
%FS
%FS
msec
V
mA
%FS
%FS
°C
°C
°C
8
6
6
3, 7
NOTES
3
3
3, 4
3, 4
5
5
5.
6.
7.
8.
Rev 1.4 6_05
2005 SMI
Silicon Microstructures, Inc.
♦
1701 McCarthy Blvd.
♦
Milpitas, CA 95035
♦
USA
Tel: 408-577-0100
♦
Fax: 408-577-0123
♦
Sales@si-micro.com
♦
www.si-micro.com
SM5812/SM5852
ADDITIONAL INFORMATION
Package Dimensions & Pin-Out
Dual Inline Pin (DIP) Option
Pin Numbers
(for both DIP & Surface Mount)
PIN
1
2
3
4
5
6
7
8
DESCRIPTION
NC
GROUND
NC
SERIAL DATA (SDA)
SERIAL CLOCK (SCL)
NC
V
exc
= 5.000 VDC
ANALOG OUTPUT
NOTES:
•
Do
not
connect to NC pins.
•
External connections to NC pins will
cause part malfunction.
•
All dimensions are shown in inches.
•
Tolerance on all dimensions
+0.005” unless otherwise specified.
Surface Mountable Pin Option
Ordering Information
Pin Configuration
3 : DIP pins, opposite direction of tubes
5 : Surface mountable pins,
Model Number
opposite direction of tubes
Tube Length
L : Long (0.480" ± 0.005")
N : No tube
Pressure Type
A : Absolute (1 port)
D : Differential (2 ports)
G : Gauge (1 port)
S : Single-ended (2 ports)
Full-Scale Pressure Ranges
SM5812
Pin Configuration
PSI
5
15
30
60
[kPa]
[34.5]
[103.4]
[206.8]
[413.7]
SM5852
001
003
008
015
030
PSI
0.15
0.30
0.80
1.50
3.00
[kPa]
[1.0]
[2.1]
[5.5]
[10.3]
[20.7]
005
015
030
060
100
SM5852 - 003 - D - 3 - L
Pressure
Range
Pressure
Type
Tube
Length
100 [689.5]
Notes
1. Absolute configuration only available in SM5822.
2. Single-ended configuration is for higher gain differential applications where differential pressure
is
always
positive.
3. Other configurations available on large orders. Consult SMI for details.
Wiring Diagrams
V
exc
= + 5.000 VDC
ANALOG OUTPUT
V
exc
= + 5.000 VDC
SERIAL CLOCK (SCL)
SERIAL DATA (SDA)
SM5812/SM5852
100 nF
100 nF
SM5812/SM5852
GROUND
GROUND
GROUND
GROUND
Wiring diagram for analog output
Notice:
Wiring diagram for digital output
Silicon Microstructures, Inc. reserves the right to make changes to the product contained in this publication. Silicon Microstructures, Inc. assumes no responsibility for the
use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement.
While the information in this publication has been checked, no responsibility, however, is assumed for inaccuracies.
Silicon Microstructures, Inc. does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably
be expected to cause failure of a life-support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications.
Today I will run the CH341 routine. CH341 is a USB to serial converter that sends and receives serial port data directly through the USB chip. The routine is as follows:I took a look at the program. I...
Defined in rom.h: #define ROM_SysCtlPeripheralEnable \ ((void (*)(uint32_t ui32Peripheral))ROM_SYSCTLTABLE[6]) Defined in sysctl.h: extern void SysCtlPeripheralEnable(uint32_t ui32Peripheral); These t...
[Nikkei BP News Agency report] In the field of system LSI (SoC) that constitutes the heart of portable terminals and digital home appliances, analog-digital mixed-load system LSI with integrated analo...
Live replay: Tektronix embedded system debugging and mixed signal system verification test using oscilloscopes : https://training.eeworld.com.cn/course/4542...
The TIA Portal software's shift instructions shift the contents of an accumulator bit by bit to the left or right. The number of bits shifted is determined by N. A left shift of N bits multiplies t...[Details]
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
1. Equipment Overview
Shell-and-tube heat exchangers are a common heat exchange device used in chemical evaporation and heating equipment. Currently, the tubesheets of shell-and-tube heat exch...[Details]
Tesla and BYD, vying for dominance in the global electric vehicle market, are reportedly considering adopting Samsung's AMOLED (active-matrix organic light-emitting diode) technology for their next...[Details]
Reflow soldering is a critical process in electronics assembly production, and the cleanliness of the reflow oven has a direct impact on product quality. Dust and residue accumulation within the ov...[Details]
EtherCAT (Ethernet for Control Automation Technology) is a real-time industrial fieldbus communication protocol based on an Ethernet-based development framework. EtherCAT is one of the fastest indu...[Details]
introduction
With the development of digital and network technologies, broadcasting technology has become increasingly diversified, with the most significant trend being the transition from an...[Details]
On August 25th, Apple's expansion in India encountered new troubles. According to Bloomberg, Foxconn Technology Group has recalled approximately 300 Chinese engineers from India, further hindering ...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
Since its invention in the mid-1940s, the microwave oven has evolved from a humble beginning to commercial use, entering homes in the 1960s and rapidly gaining popularity. Its basic functionality a...[Details]
introduction
As “energy conservation and emission reduction” has become an indicator of the National Economic Development Outline of the 11th Five-Year Plan, people’s awareness of green enviro...[Details]
introduction
According to the China Fire Statistics Yearbook, electrical fires accounted for more than 30% of fire accidents in the past decade, and the trend is increasing year by year. They ...[Details]
In the scorching summer, electric fans are a must-have for cooling down people's homes. However, I believe most people have encountered this situation: the fan is plugged in, the switch is pressed,...[Details]
Batteries, at the core of new energy vehicles, are crucial to vehicle performance and range. Existing automotive batteries are categorized into lead-acid and lithium batteries. Currently, new energ...[Details]
With the support and encouragement of national policies, some Internet car manufacturers have also joined the new energy vehicle manufacturing industry. From the perspective of new car manufacturer...[Details]