EEWORLDEEWORLDEEWORLD

Part Number

Search

3517/34 100SF

Description
CBL RIBN 34COND 0.050 GRAY 50'
CategoryWire/cable   
File Size369KB,3 Pages
Manufacturer3M
Websitehttp://3M.com/esd
Environmental Compliance
Download Datasheet Parametric View All

3517/34 100SF Overview

CBL RIBN 34COND 0.050 GRAY 50'

3517/34 100SF Parametric

Parameter NameAttribute value
Cable typeFlat cable, flat sleeve
Number of conductors34
spacing0.050"(1.27mm)
length50.0'(15.24m)
Wire gauge28 AWG
Number of wire strands7 strands/36 AWG
shieldshield
Casing colorgrey
Belt thickness0.110"(2.79mm)
Strip width1.830"(46.48mm)
Sheath (insulation) materialPolyvinyl chloride (PVC)
Voltage300V
Operating temperature-20°C ~ 80°C
gradeUL Type 2912
characteristic-
conductor materialCopper, tin plated
Insulation resistance10 G ohms
first conductor markred
3M
Shielded/Jacketed, Flat Cable
.050" 28 AWG Stranded, PVC/PVC
3517 Series
• Meets external wiring requirements of National
Electrical Code, Article 725 (CL2)
• UL listed for USA and Canadian markets
• 28 AWG stranded wire on .050 inch centers permits
mass termination to broad line of IDC connectors
• 360 degree expanded copper shielding provides 20 db
average shielding effectiveness
• Primary cable is zippable for branching or discrete
terminations
• See the Regulatory Information Appendix (RIA) in
the “RoHS compliance” section of www.3M.com/
Interconnects for compliance information
(RIA E1 & C1 apply)
Date Modified: December 8, 2009
TS-0069-D
Sheet 1 of 2
Physical
Jacket Material:
Polyvinyl Chloride (PVC)
Color:
Black
Primary Material:
PVC
Color:
Gray
Marking:
Standard:
(UL) CL2 75C 28 AWG or AWM 20879 3M NU C
AWM IIA/B 80C 300V FT1 EU <50V
Conductors:
28 AWG, 7 × 36 AWG [ 7 × Ø 0.127 ] Tinned Stranded Copper
Shielding Material:
Expanded Copper
Electrical
Voltage Rating:
Insulation Resistance:
Characteristic Impedance:
Capacitance:
Inductance:
Propagation Delay:
Velocity of Propagation:
USA: N.E.C. 725, CL2 or AWM 300V
(Primary Cable) > 1 × 10
10
Ω/10
ft. [ 3 m ]
Unbalanced
70
Ω
21.5 pF/ft [ 70.5 pF/m ]
0.11 μH/ft [ 0.35 μH/m ]
1.51 ns/ft [ 4.95 ns/m ]
67%
Balanced
119
Ω
12.7 pF/ft [ 41.7 pF/m ]
0.18 μH/ft [ 0.59 μH/m ]
1.51 ns/ft [ 4.95 ns/m ]
67%
Canada: <50V
EU: <50V
Note: Unbalanced is measured between ground-signal-ground conductors, with shield grounded. Balanced is measured between signal conductors within a pair, with the shield floating.
Environmental
Temperature Rating:
Flammability Rating:
USA: CL2; 75°C or AWM: -20°C to +80°C
USA: N.E.C. 725, CL2
Canada: 80°C
Canada: FT1
UL File No.: E118773, Power Limited Circuit Cable: CL2 (or AWM Style 20879)
3
Interconnect Solutions
http://www.3M.com/interconnects/
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
Excuse me, when calculating the loss of this resistor R1, should we use integration?
This R1, as the absorption resistor of the MOS tube, is calculated to have a loss of 0.09W. Is it calculated by integration? Figure 2 is the test waveform of the voltage across the resistor. I am not ...
西里古1992 Analog electronics
Is this a synchronous rectifier circuit?
Is this part of the circuit a synchronous rectification circuit? What do the two pairs of resistors and capacitors R1, C1, R9, and C4 mean?...
Knight97538 Power technology
Newcomer Report
This is the first time I know the website EEWORLD. I downloaded a very useful document with my points. I will come back in the future....
Pennan Circuit Observation Room
I always thought I didn’t have good opportunities, but now I realize that’s not the case.
Ever since I switched from hardware to Linux software, every time I see a job opening for a Linux development position, I always sigh at the requirements and think that I don’t know this or that. I al...
Nubility Talking
I redeemed a JD card on the 3rd, but it’s not sent to me today, the 15th. I contacted via WeChat and they said it would be sent to me on the 18th or 19th, but it still hasn’t been sent to me.
I redeemed a JD card on the 3rd, but it’s not issued to me yet, it’s the 15th today. I contacted via WeChat and they said it would be issued to me on the 18th or 19th, but it still hasn’t been issued ...
QWE4562009 Suggestions & Announcements
Reed Switch Relay Applications
Hello everyone, does anyone have experience using reed switch relays? What should we pay attention to when using this type of relay? Based on my understanding of the simple structure of this type of r...
呜呼哀哉 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2853  2432  2132  2545  2664  58  49  43  52  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号