2210-T230-K0M1-H231-20A

Description
CIR BRK THERM-M 20A 250VAC/65VDC
CategoryCircuit protection   
File Size319KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet Parametric View All

2210-T230-K0M1-H231-20A Online Shopping

Suppliers Part Number Price MOQ In stock  
2210-T230-K0M1-H231-20A - - View Buy Now

2210-T230-K0M1-H231-20A Overview

CIR BRK THERM-M 20A 250VAC/65VDC

2210-T230-K0M1-H231-20A Parametric

Parameter NameAttribute value
Circuit breaker typeThermomagnetic
Rated current20A
Rated voltage - AC250V
Rated voltage - DC65V
Number of poles3
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typeDIN rail
Thermal-Magnetic Circuit Breaker 2210-T2...
Description
One, two and three pole thermal-magnetic circuit breakers with trip-free
mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934).
Featuring a combi-foot design for both symmetric and asymmetric rail
mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status
signalling. Two and three pole models are internally linked to ensure that
both/all poles trip in the event of an overload on one pole, even if the
actuator is held in the ON position. This CBE can be supplied in current
ratings up to 32 A with a choice of characteristic curves. All screw
terminals are recessed for safety. Approved to CBE standard EN 60934
(IEC 60934).
Typical applications
Process control equipment, robotics, machine tool control,
communications systems, instrumentation.
1-pole
2210-T2..
1
3-pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V
(UL: AC 277/480 V; DC 65 V)
Current rating range
0.1...32 A for curves M1, T1
0.1...16 A for curves F1, F2
Auxiliary circuit
1 A, AC 240 V / DC 65 V, resistive
(min. 10 V / 10 mA)
Typical life
3 AC 433 V; AC 250 V: 0.1...25 A
10,000 operations at 1 x I
N
, inductive
DC 65 V:
0.1...32 A
10,000 operations at 1 x I
N
, inductive
3 AC 433 V; AC 250 V: 32 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-30...+60 °C (-22...+140 °F) T 60
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
test voltage
operating area
AC 3,000 V
main/aux. circuit
AC 3,000 V
pole/pole
AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...5 A
400 A
6...32 A
800 A
curves F1, F2, M1, T1: 0.1...16 A 2,500 A (at DC 32 V)
Interrupting capacity (UL 1077)
I
N
0.1...16 A
20...25 A
Preferred types
Preferred types
1-pole
2210-T210-K0M1-H121-
2-pole
2210-T220-K0M1-H221-
Standard current ratings (A)
0.5 1
x
x
2
x
3
x
4
x
5
x
6
x
8 10 16 20
x
x
x
x
0.5 1
2
x
3
4
x
5
6
x
8 10 16 20
x
x
x
Ordering information
Type No.
2210
single and multipole thermal-magnetic circuit breaker
Mounting
T
rail mounting
Actuator design
2
toggle
Number of poles
1
single pole protected
2
2-pole protected
3
3-pole protected
Accessories
0
without accessories
Terminal design (main contacts)
K0
screw terminals
Characteristic curve
F1
fast acting: therm.1.01-1.4xI
N
;
magn.2-4xI
N
DC (DC only)
F2
fast acting: therm.1.01-1.4xI
N
;
magn.3,5-6,5xI
N
AC/4,5-8,5xI
N
DC
M1
standard delay: therm. 1.01-1.4xI
N
;
magn. 6-12xI
N
AC, 7.8-15.6xI
N
DC
T1
delayed: therm. 1.01-1.4xI
N
; magn. 10-20xI
N
AC
Auxiliary contact design
H
without intermediate position
Auxiliary contacts
1
with auxiliary contacts
2
auxiliary contacts on pole 1 only
(multipole devices)
Auxiliary contact function (see diagrams)
2
1 N/O contact
3
1 N/C contact
Auxiliary contact - terminal design
1
screw terminals
Current ratings
0.1...32 A
2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A
ordering example
AC 277 V
1-pole
AC 277/480 V
2-/3-pole
DC 65 V
Degree of protection
(IEC 60529/DIN 40050)
Vibration curves F1, F2:
curves M1, T1:
5,000 A
5,000 A
2,000 A
2,000 A
2,000 A
2,000 A
operating area IP30
terminal area IP20
3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5
10 g (11 ms), direction 6
curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5
20 g (11 ms), direction 6
to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 60 g per pole
1812
www.e-t-a.de
1
Wince 320*240 display driver development
I want to change the resolution from 640*480 to 320*240. After the ce image is started, the system icon is obviously too large. But it can be displayed in full screen. What is wrong?...
andyliu007 Embedded System
Urgent question: what is uboot in dnw?
In the USB port menu of DNW, transmit means loading files into the onboard memory via USB, but what about uboot? Is there any difference?...
navyin Embedded System
[Launchpad]Use of IO ports P2.6 and P2.7
[color=#525252]Hardware configuration: [/color] [color=#525252]1.MSP430-Launchpad(MSP430_EXP430_G2) onboard chip M430G2553 [/color] [color=#525252]2.Two LED lights [/color] [color=#525252]Wiring diagr...
qwqwqw2088 Microcontroller MCU
How to choose the power chip power of the circuit board
[size=5][font=宋体][align=left]How to choose the power chip power of the circuit board. If you only know that you need several different voltages, how do you choose the power of these power chips? [/ali...
JFET Analogue and Mixed Signal
Basic principles of PWM control
PWM pulse width modulation controls the output voltage by changing the pulse width and controls the output frequency by changing the cycle. The change of the output frequency can be achieved by changi...
eeleader Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2533  2288  2659  942  638  51  47  54  19  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号