Consult LTC Marketing for parts specified with wider operating temperature ranges. *The temperature grade is identified by a label on the shipping container.
Consult LTC Marketing for information on non-standard lead based finish parts.
For more information on lead free part marking, go to:
http://www.linear.com/leadfree/
For more information on tape and reel specifications, go to:
http://www.linear.com/tapeandreel/
ELECTRICAL CHARACTERISTICS
SYMBOL
V
OS
PARAMETER
Input Offset Voltage
(LT6003C/I, LT6004C/I, LT6005C/I) The
l
denotes the specifications which
apply over the full operating temperature range, otherwise specifications are at T
A
= 25°C. V
S
= 1.8V, 0V, V
CM
= 0.5V; V
S
= 5V, 0V,
V
CM
= 2.5V, V
OUT
= half supply, R
L
to ground, unless otherwise noted.
CONDITIONS
LT6003S5, LT6004MS8
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
LT6005GN
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
LT6004DD, LT6005DHC
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
LT6003DC
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
l
l
MIN
TYP
175
MAX
500
725
950
650
925
1.15
850
1.15
1.4
950
1.3
1.6
5
7
UNITS
µV
µV
µV
µV
µV
mV
µV
mV
mV
µV
mV
mV
µV/°C
µV/°C
190
l
l
290
l
l
290
l
l
l
l
ΔV
OS
/ΔT
Input Offset Voltage Drift (Note 5)
S5, MS8, GN
DC, DD, DHC
2
2
600345fd
3
LT6003/LT6004/LT6005
ELECTRICAL CHARACTERISTICS
SYMBOL
I
B
PARAMETER
Input Bias Current (Note 7)
(LT6003C/I, LT6004C/I, LT6005C/I) The
l
denotes the specifications which
apply over the full operating temperature range, otherwise specifications are at T
A
= 25°C. V
S
= 1.8V, 0V, V
CM
= 0.5V; V
S
= 5V, 0V,
V
CM
= 2.5V, V
OUT
= half supply, R
L
to ground, unless otherwise noted.
CONDITIONS
V
CM
= 0.3V, 0°C ≤ T
A
≤ 70°C
V
CM
= V
+
– 0.3V, 0°C ≤ T
A
≤ 70°C
V
CM
= 0.3V, –40°C ≤ T
A
≤ 85°C
V
CM
= V
+
– 0.3V, –40°C ≤ T
A
≤ 85°C
V
CM
= 0V
V
CM
= 0.3V
V
CM
= V
+
– 0.3V
V
CM
= 0V
0.1Hz to 10Hz
f = 100Hz
f = 100Hz
Differential
Common Mode
V
S
= 1.8V
V
CM
= 0V to 0.7V
V
CM
= 0V to 1.8V, S5, MS8, GN
V
CM
= 0V to 1.8V, DC, DD, DHC
V
S
= 5V
V
CM
= 0V to 3.9V
V
CM
= 0V to 5V, S5, MS8, GN
V
CM
= 0V to 5V, DC, DD, DHC
Input Offset Voltage Shift (Note 7)
V
CM
= 0V to V
+
– 1.1V
V
CM
= 0V to V
+
, S5, MS8, GN
V
CM
= 0V to V
+
, DC, DD, DHC
Guaranteed by CMRR
V
S
= 1.6V to 6V, V
CM
= 0.5V, 0°C ≤ T
A
≤ 70°C
V
S
= 1.7V to 6V, V
CM
= 0.5V, –40°C ≤ T
A
≤ 85°C
Guaranteed by PSRR, 0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
V
S
= 1.8V
R
L
= 20kΩ, V
OUT
= 0.25V to 1.25V
V
S
= 5V
R
L
= 20kΩ, V
OUT
= 0.25V to 4.25V
l
l
l
l
l
l
l
l
MIN
TYP
5
40
5
40
0.13
5
7
5
3
325
12
10
2000
6
MAX
90
140
120
170
1.4
80
80
100
UNITS
pA
pA
pA
pA
nA
pA
pA
pA
µV
P-P
nV/√Hz
fA/√Hz
GΩ
GΩ
pF
dB
dB
dB
dB
dB
dB
I
OS
Input Offset Current (Note 7)
Input Noise Voltage
e
n
i
n
R
IN
C
IN
CMRR
Input Noise Voltage Density
Input Noise Current Density
Input Resistance
Input Capacitance
Common Mode Rejection Ratio
(Note 7)
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
73
63
60
88
72
69
100
80
78
115
90
86
7
0.16
0.23
155
1.3
1.8
V
+
95
95
µV
mV
mV
V
dB
dB
V
V
Input Voltage Range
PSRR
Power Supply Rejection Ratio
Minimum Supply Voltage
A
VOL
Large Signal Voltage Gain
(Note 7)
0
80
78
1.6
1.7
25
15
100
60
150
500
15
110
45
200
2
1.5
0.5
2
1.5
0.5
5
V/mV
V/mV
V/mV
V/mV
50
240
100
350
mV
mV
mV
mV
mA
mA
mA
mA
mA
mA
1
1.4
1.6
1.2
1.6
1.9
µA
µA
µA
µA
µA
µA
600345fd
V
OL
V
OH
I
SC
Output Swing Low (Notes 6, 8)
Output Swing High (Notes 6, 9)
Short Circuit Current (Note 8)
No Load
I
SINK
= 100µA
No Load
I
SOURCE
= 100µA
Short to GND
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
Short to V
+
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
7
I
S
Supply Current per Amplifier
V
S
= 1.8V
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
V
S
= 5V
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
0.85
1
l
l
4
LT6003/LT6004/LT6005
ELECTRICAL CHARACTERISTICS
SYMBOL
GBW
SR
PARAMETER
Gain Bandwidth Product
Slew Rate (Note 11)
f = 100Hz
A
V
= –1, R
F
= R
G
= 1MΩ
0°C ≤ T
A
≤ 70°C
–40°C ≤ T
A
≤ 85°C
V
OUT
= 1.5V
P-P
(Note 10)
l
l
(LT6003C/I, LT6004C/I, LT6005C/I) The
l
denotes the specifications which
apply over the full operating temperature range, otherwise specifications are at T
A
= 25°C. V
S
= 1.8V, 0V, V
CM
= 0.5V; V
S
= 5V, 0V,
V
CM
= 2.5V, V
OUT
= half supply, R
L
to ground, unless otherwise noted.
CONDITIONS
MIN
0.55
0.4
0.2
TYP
2
0.8
MAX
UNITS
kHz
V/ms
V/ms
V/ms
Hz
FPBW
Full Power Bandwidth
170
(LT6003H, LT6004H, LT6005H) The
l
denotes the specifications which apply over the full specified temperature range of –40°C ≤ T
[i=s] This post was last edited by paulhyde on 2014-9-15 09:18 [/i] 2007 National Undergraduate Electronic Design Competition Instrumentation Category Topic Discussion Attached Topic...
I used Qt when I had nothing to do. I heard that Nokia has sold Qt now. It is said that Qt5 will support Android and WP8. Take a look at my interface. Is there anyone who has worked on Qt? Let's excha...
[Lazy self-care fish tank control system] PRINTF output under RTT in Keil environment
Today I tried using SEGGER's RTT print output program PRINTF
1. In printf.h, we need to make a compilation choice ...
蓝雨夜onsemi and Avnet IoT Innovation Design Competition
WPG Holdings' Cathay Pacific Group launches the best power management solution for car audio and video: Car audio and video systems are no longer just CDs or cassette tapes, but have evolved into all-...
Inductance is a special device that can change the current. It is relatively rarely used in digital circuits and is generally used in power supply related parts. [size=5][color=#ff0000][b]1. Concept [...
Due to the significant increase in electronic devices in automotive and industrial applications, the automotive and industrial markets continue to play an important role in China's electronics in...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
In recent years, with the rapid development of the information industry, dot matrix LED display screens have been widely used in various advertising and information display systems such as the fina...[Details]
Today, the value of electronic components in cars accounts for 15-20% of the total vehicle. In the future, this proportion may be as high as 30-40% as more safety electronics, fuel consumption and ...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
With the continuous advancement of various technologies in the field of measurement and control, the baseband subsystem of general measurement and control equipment has entered the fourth generation o...[Details]
Abstract: Based on the ZigBee parking lot SMS car search system, the location of the vehicle in the parking lot is sent to the owner through SMS, which is convenient for the owner to quickly find ...[Details]
Rated capacity refers to the maximum output power of the UPS (the product of voltage V and current A).
Usually, the UPS power supplies sold on the market are marked with "W" (watt) for smaller...[Details]
In industry, voltage 0…5 (10) V or current 0 (4)…20 mA is usually used as a method for analog signal transmission, which is also a method often used by programmable controllers. So what are the dif...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
1. Fully understand the design requirements of all parties and determine the appropriate solution.
When starting a hardware development project, the original driving force will come from many a...[Details]