EEWORLDEEWORLDEEWORLD

Part Number

Search

FN9280B-10-06

Description
AC power input module 10A SNGL STAGE FLTR FLANGE-MEDICAL
CategoryThe connector    The connector   
File Size2MB,10 Pages
ManufacturerSchaffner
Environmental Compliance
Download Datasheet Parametric View All

FN9280B-10-06 Online Shopping

Suppliers Part Number Price MOQ In stock  
FN9280B-10-06 - - View Buy Now

FN9280B-10-06 Overview

AC power input module 10A SNGL STAGE FLTR FLANGE-MEDICAL

FN9280B-10-06 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSchaffner
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact materialNOT SPECIFIED
DATASHEET
IEC Inlet Filters FN 9280
Ultra Compact and Versatile Filtered Power Entry Module
Single stage filter
Ultra compact design
Rated currents up to 10 A
dual-fuse holder
Fuses Ø5x20 mm
2-pole rocker switch
Good attenuation performance
Faston or spring cage terminals
Check the video of our IEC Inlet
Filters FN 9280 and FN 9290 on
Youtube!
Approvals
(CQC except HI-types; Patent US 20110227692/US
8766761; CN ZL201080069589.0)
Performance indicators
Choosing FN 9280/90 product line brings you the
rapid availability of a standard filter associated with
the necessary safety acceptances and a high
attenuation performance. For higher attenuation
performance the FN 9290 family with a dual stage
filter and identical panel cut-out can be used.
Standard IEC connector filters are a practical solution
to pass EMI system approval in a short time. A wide
selection of amperage ratings, mounting possibilities
and also filters for medical applications are designed
to offer you the best solution.
Features and benefits
Good conducted attenuation performance, based
on chokes with high saturation resistance and
excellent thermal behavior
50,000 cycles
P –> PE 2000 VAC for 2 sec (standard types)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 760 VAC for 2 sec
>1,000,000 hours
– 25°C to +85°C (25/85/21)
UL 1283, CSA 22.2 No. 8 1986, EN 60939, EN 60950, EN
60601-1, UL 544, EN 60320
UL 94 V-2 or better
250 VAC, 50/60 Hz
1 to 10 A @ 40°C max.
DC to 400 Hz
10 A, 125 VAC; 10 A, 250 VAC; 1/3 HP
10 A (4 A), 250 VAC**
Inrush current 82 A
6,000 on-off operations according to UL 1054
10,000 on-off operations according to ENEC
Standard: <500 uA at 250 VAC/50 Hz
Medical: <5 uA at 250 VAC/50 Hz
IP 40 according to IEC 60529 (front side)
2 fuses (Ø5 x 20 mm) max. 250 V (certified to IEC
60127-6)
IP 20 spring cage safe against finger touch
0.2 –1.5 mm2 / 24 –16 AWG single or flexible wire
2-pole, dark not illuminated, Marking I - 0
Technical specifications
Mechanical life
High potential test voltage
Deep-drawn iron-sheet housing for best possible
shielding against magnetic fields
Rear/front flange mounting or snap-in versions
Dual and additional spare fuse holder
2-pole rocker switch
Faston or spring cage terminals
Medical version (B Type) according IEC/EN 60601-1
All versions according IEC/EN 62368-1
MTBF @ 40°C/230 V (Mil-HB-217F)
Temperature range (operation and storage)
Design corresponding to
Flammability corresponding to
Maximum continuous operating voltage
Rated currents
Operating frequency
Switch ratings
USA (UL) and Canada (C-UL)
Europe (ENEC)
Electrical specifications
Typical applications
Portable electrical and electronic equipment
Consumer goods
EDP and office equipment
Single-phase and switch-mode power supplies
Test and measurement equipment
Medical electrical devices (MD) and
In-Vitro-
Diagnostics (IVD) equipment
Audio/Video, information and communication
technologies
Leakage current
Protection category
Fuse holder
Terminals
Spring cage wire range
Rocker switch
Typical electrical schematic
* 10 A version is 8 A UL and CSA approved
** Value in () relates to the inductive current charge: cos γ = 0.65
Here is a Tai Chi Bagua diagram of the radio frequency industry
I remember a friend asked about this picture last timeI found it yesterday while searching through boxes and cabinets. I don't know where it is.The pictures are for your convenience. Of course, the or...
btty038 RF/Wirelessly
I think it's good - Linux advanced application programming video
This is a video of Linux application programming that I have accumulated in the past. I think it is pretty good, so I would like to share it. [url=http://www.huoweb.cn/?p=411]Linux Advanced Applicatio...
zzhere2007 Embedded System
synplify software help
Does anyone have the synplify software download and crack? Please contribute one. I can't seem to download it from the top electronic development website. Now I can only ask for help from the almighty...
不足论 FPGA/CPLD
About C2000 support for C standard library? Use sprintf(str, "%d", var) to run fast
Why does sprintf(str, "%d", var) work when compiled in CCS, but crashes when debugged? The compiler configuration is turned on....
swordman Microcontroller MCU
Please share your experience in learning analog electronics
I want to learn analog electronics, but I don't know where to start. I need help: I learned analog electronics in college, but I only had a rough understanding. After I graduated, I found that designi...
JFET Analog electronics
Looking for a PIC assembly program for 1602 LCD 4-line mode
I am a novice, and I need a usable PIC assembly program for 1602 with 4-bit data bus. Can anyone help me?...
sidneyysk Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1437  987  1236  2199  966  29  20  25  45  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号