EEWORLDEEWORLDEEWORLD

Part Number

Search

RP415-64-100-S

Description
Power line filter FILTER COMPACT 3- PHASE WYE 64A 100NF
CategoryThe power supply    Power regulation    The power line filter   
File Size2MB,4 Pages
ManufacturerAstrodyne TDI
Environmental Compliance
Download Datasheet Parametric Compare View All

RP415-64-100-S Online Shopping

Suppliers Part Number Price MOQ In stock  
RP415-64-100-S - - View Buy Now

RP415-64-100-S Overview

Power line filter FILTER COMPACT 3- PHASE WYE 64A 100NF

RP415-64-100-S Parametric

Parameter NameAttribute value
MakerAstrodyne TDI
Product CategoryPower line filter
filter typeSingle Stage Power
Voltage rating480 V
Current rating64 A
Installation styleChassis Mount
Termination typeScrew
Leakage current1 mA
seriesRP415
EncapsulationBulk
working frequency50 Hz / 60 Hz
capacitance0.1 uF
high125 mm
length140 mm
width125 mm
Maximum operating temperature+ 50 C
Minimum operating temperature- 25 C
RP
RP415 Series
RP415
COMPACT 3PHASE WYE TO 160A
CHASSIS MOUNT FILTER
ROHS COMPLIANT
RADIUS POWER
Your Power Partner
3-Phase WYE Single Stage Power Line Filter
SPECIFICATIONS
Operating Freq.
Usable Freq.
Max. Operating Voltage
Ambient Temperature
Climatic Category
Hipot Rating (L-G)
Terminals (-T)
:
:
:
:
:
:
:
50/60Hz
DC - 400Hz
480V +10%
-25 to 50C
25/100/21
3500VDC
S: 8/16/25/36 (M5)
64/80 (M6)
120/160 (M10)
UR, CSA, EN60939
LEAKAGE CURRENT
Y-cap, nF
0
10
100
1000
2000
mA,
480V/60Hz
0
0.1
1
10
20
Safety Approvals
:
PART NUMBER/ ORDERING
RP415
-X
(Amps)
8
16
25
36
64
80
120
160
-Y
(Ycap, nF)
0
10
100
1000
2000
-T
S
Weight
LBS (KG)
Typ.
3.9 (1.8)
3.9 (1.8)
4.8 (2.2)
4.8 (2.2)
5.8 (2.6)
7.0 (3.2)
15.0 (6.8)
16.0 (7.3)
SCHEMATIC
Note:
Use any combination of -Y with any -X (Amps) rating
e.g. RP415-25-100-S (25 Amps with 100nF Ycap)
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
102

RP415-64-100-S Related Products

RP415-64-100-S RP415-160-200-S RP415-16-100-S RP415-36-100-S RP415-25-100-S RP415-80-100-S RP415-120-150-S RP415-8-100-S
Description Power line filter FILTER COMPACT 3- PHASE WYE 64A 100NF Power Line Filters FILTER COMPACT 3- PHASE WYE 160A 200NF Power Line Filters FILTER COMPACT 3- PHASE WYE 16A 100NF Power Line Filters FILTER COMPACT 3- PHASE WYE 36A 100NF Power line filter FILTER COMPACT 3- PHASE WYE 25A 100NF Power line filter FILTER COMPACT 3- PHASE WYE 80A 100NF Power line filter FILTER COMPACT 3- PHASE WYE 120A 150NF Power line filter FILTER COMPACT 3- PHASE WYE 8A 100NF
Product Category Power line filter Power Line Filters Power Line Filters Power Line Filters Power line filter Power line filter Power line filter Power line filter
Maker Astrodyne TDI - - - Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI
filter type Single Stage Power - - - Single Stage Power Line Filters Single Stage Power Single Stage Power Single Stage Power
Voltage rating 480 V - - - 480 V 480 V 480 V 480 V
Current rating 64 A - - - 25 A 80 A 120 A 8 A
Installation style Chassis Mount - - - Chassis Mount Chassis Mount Chassis Mount Chassis Mount
Termination type Screw - - - Stud Screw Screw Screw
series RP415 - - - RP415 RP415 RP415 RP415
Encapsulation Bulk - - - Bulk Bulk Bulk Bulk
working frequency 50 Hz / 60 Hz - - - 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz
capacitance 0.1 uF - - - 0.1 uF 0.1 uF 0.15 uF 0.1 uF
high 125 mm - - - 115 mm 110 mm 130 mm 80 mm
length 140 mm - - - 130 mm 160 mm 180 mm 120 mm
width 125 mm - - - 125 mm 140 mm 140 mm 115 mm
Maximum operating temperature + 50 C - - - + 50 C + 50 C + 50 C + 50 C
Minimum operating temperature - 25 C - - - - 25 C - 25 C - 25 C - 25 C
Heat dissipation problems and solutions for power management systems
Designing a power converter is not easy because it involves many aspects of technical knowledge. Excellent power converter design engineers must have a certain understanding of analog and mixed-signal...
kolong Power technology
Solution to the system performance degradation caused by permanent storage of WinCE registry
When we finally realized the permanent storage of the registry, we found that we had to face a new problem: Since the registry needs to be saved to a permanent storage (such as NAND Flash), each modif...
Wince.Android Embedded System
EEWORLD University Hall----Industry Week- Topic 7: TI sensorless motor drive system algorithm design with PFC
Industry Week - Topic 7: TI sensorless motor drive system algorithm design with PFC : https://training.eeworld.com.cn/course/4040...
hi5 Talking
How to implement modbus communication between atmega128 and plc
The main purpose is to realize modbus communication between plc and atmega128 microcontroller. How to program the microcontroller. Thank you all....
火页 Microchip MCU
Bear Pai Hongmeng Development Board Review - [Use HUAWEI DevEco Device Tool to create a new project - Blink]
[i=s]This post was last edited by Unseen on 2021-7-1 00:24[/i]In the previous chapter, we used command line tools to compile a project. In actual use, downloading and installing various command line t...
未见 Programming Basics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2233  1567  2383  2872  2478  45  32  48  58  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号