30A24-P30-F-M-E

Description
Non-isolated DC/DC converterDC to Regulated High-Voltage DC Converter, PCB or Chassis-Mount Module, Unipolar, Single Output
CategoryThe power supply    DC/DC converters    The isolated DC/DC converter   
File Size1MB,3 Pages
ManufacturerAdvanced Energy
Environmental Compliance
Download Datasheet Parametric View All

30A24-P30-F-M-E Online Shopping

Suppliers Part Number Price MOQ In stock  
30A24-P30-F-M-E - - View Buy Now

30A24-P30-F-M-E Overview

Non-isolated DC/DC converterDC to Regulated High-Voltage DC Converter, PCB or Chassis-Mount Module, Unipolar, Single Output

30A24-P30-F-M-E Parametric

Parameter NameAttribute value
MakerAdvanced Energy
Product CategoryNon-isolated DC/DC converter
productNon-Isolated / POL
Number of outputs1 Output
Output Power30 W
Input voltage23 V to 30 V
Output voltage—channel 10 V to 30000 V
Output current—channel 11 mA
Installation styleChassis
Output typePositive
seriesA
Maximum operating temperature+ 65 C
Minimum operating temperature- 40 C
SINGLE OUTPUT HIGH VOLTAGE MODULES
30A-40A SERIES
30kV to 40kV High Voltage Biasing Supplies
The 30A-40A Series of regulated, high-voltage DC-DC converters are
an extension of the A Series, directly addressing the needs of the
miniature PCB or chassis-mount ≥30kV application. Designed and
built utilizing state-of-the-art power conversion topology, these units
feature surface-mount technology and encapsulation techniques
providing high reliability and low cost. Typical applications
for the
30A-40A Series include the following: electrostatic discharge testers,
plasma, electrostatic, x-ray, and wire testers.
19
0 to 30kV, 35kV or 40kV output
4, 15 or 30 watts of output power
Maximum Iout capability down to 0 Volts
Wide input voltage range
Indefinite output short-circuit protection
CONDITIONS
Output current & voltage monitors
Fixed-frequency, low-stored-energy design
>400,000 hour MTBF @65°C
UL/cUL Recognized Component; CE Mark (LVD & RoHS)
MODELS
UNITS
24V
+ 23 to 30
+ 9 to 32
< 30
30A < 0.30, 35A < 0.20, 40A < 0.38
~1800
< 80
VDC
VDC
mA
A
mA
mA p-p
PARAMETER
INPUT
Voltage Range
Voltage Range
Current
Current
Current
AC Ripple Current
Full Power
12V
+ 11 to 16
+ 9 to 32
< 30
30A < 0.25, 35A < 0.35, 40A < 0.38
~ 800
< 80
Derated Power Range
Standby / Disable
No Load, Max Eout
Max Load, Max Eout
Nominal Input, Full Load
OUTPUT
Voltage Range
Nominal Input Voltage / Model
Power
Current
Current Scale Factor
Voltage Monitor Scaling
Ripple
Ripple with -F-M Option
Dynamic Load Regulation
Line Regulation
Static Load Regulation
Stability
Input Impedance
Adjust Resistance
Adjust Logic
Output Voltage & Impedance
30A
Nominal Input
12
Nominal Input, Max Eout
Iout Entire Output Voltage Range
Full Load
Full Load, Max Eout, 300pF bypass Cap.
Full Load, Max Eout, 300pF bypass Cap.
½ to Full Load, Max Eout per 0.1mA
Nom. Input, Max Eout, Full Power
No Load to Full Load, Max Eout
30 Min. warmup, per 8 hr/ per day
Nominal Input
Typical Potentiometer Values
0 to +5 for +Out, +5 to 0 for - Out
T=+25°C
4
0.13
.140
0.025
0.021
<10.0
0 to 30,000
24
15
0.50
.173
0.039
0.028
<10.0
24
30
1.0
.181
0.058
0.048
<10.0
12
4
0.11
.158
0.025
0.016
<10.0
35A
0 to 35,000
24
15
0.42
.179
0.040
0.034
<10.0
< 0.01 %
< 0.01%
< 0.01% / < 0.02%
24
30
0.86
.184
0.075
0.040
<10.0
12
4
0.10
.077
0.030
0.007
<10.0
40A
0 to 40,000
24
15
0.37
.089
0.060
0.025
<10.0
24
30
0.75
.092
0.064
0.053
<10.0
VDC
VDC
Watts
mA
mA/V
-
%V p-p
%V p-p
V pk
VDC
VDC
VDC
MΩ
-
-
VDC
°C
PPM/°C
°C
°C
-
-
G’s
G’s
Specifications subject to change without notice.
1000:1 ± 2% into 10MΩ
PROGRAMMING & CONTROLS
ALL TYPES
+ Output Models 1.1MΩ to GND, - Output Models 1.1MΩ to +5 Vref
10K to 100K (Pot across Vref. & Signal GND, Wiper to Adjust)
+4.64 VDC for +Output or +0.36 for -Output = Nominal Eout
+ 5.00VDC ± 2%, Zout = 464Ω ± 1%
0 to +0.5 Disable, +2.4 to 32 Enable (Default = Enable)
Enable/Disable
ENVIRONMENTAL
Operating
Coefficient
Thermal Shock
Storage
Humidity
Altitude
Shock
Vibration
Full Load, Max Eout, Case Temp.
Over the Specified Temperature
Mil-Std 810, Method 503-4, Proc. II
Non-Operating, Case Temp.
All Conditions, Standard Package
Standard Package, All Conditions
Mil-Std-810, Method 516.5, Proc. IV
Mil-Std-810, Method 514.5, Fig.514.5C-3
STANDARD
-40 to +65
± 50
-40 to +65
-55 to +105
0 to 95% non-condensing
-25PPM
+10 to +45
± 25
Sea Level through Vacuum (Vacuum may require -P2 option, contact factory for details.)
20 (Standard), 40 (-C Option)
10 (Standard), 20 (-C Option)
Making High Voltage Easier!
®
ULTRAVOLT
®
Higher Service, Higher Performance, Higher Reliability
©2011, UltraVolt Inc. All rights reserved.
[Help] Thermoelectric infrared
I'm making a little infrared alarm gadget recently, I just want to realize a basic function, and I'm also considering a course design for a junior. Please recommend me a thermoelectric infrared. Don't...
常见泽1 51mcu
RoHS on LM3S811 Development Board
I don't know if you noticed the RoHS mark when you got the lm3s811 board, so I searched on Baidu and found out that it's all knowledge. It's best that I don't show off my skills before an expert.RoHSE...
鑫海宝贝 Microcontroller MCU
How to install the temperature and humidity sensor sht10
I have posted a post before, which "inherited" the problem of being too long-winded and narrative in my past posts. I must correct it in the future. I want to start this post with a good start. Last n...
辛昕 Sensor
Help! Is there anyone familiar with LM3S811?
Recently, the teacher asked us to use the LM3S811 board. However, since I am a rookie, I don’t understand it and I am confused. I wonder if there is any expert who is willing to teach me. I will be ve...
wolegecha MCU
Research on Inverter Based on DSP and Incremental PI Voltage Loop Control
Abstract: This paper studies an inverter based on digital control. The scheme adopts voltage instantaneous value loop control to improve output stability while taking into account output dynamic perfo...
zbz0529 Power technology
Error in converting numbers into characters in C language programming
In the program above, the value in the Curr_DO register is converted into characters and sent to the LCD module for display. Now my Curr_DO monitors a value of 1930. As usual, it should be converted i...
面纱如雾 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2492  1381  2628  24  87  51  28  53  1  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号