EEWORLDEEWORLDEEWORLD

Part Number

Search

ECSH4HF.08D

Description
Industrial current sensor 120VAC ISOLATED SPDT CURRENT SENSOR
CategoryThe sensor    Current sensor    Industrial current sensor   
File Size359KB,4 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Environmental Compliance
Download Datasheet Parametric Compare View All

ECSH4HF.08D Overview

Industrial current sensor 120VAC ISOLATED SPDT CURRENT SENSOR

ECSH4HF.08D Parametric

Parameter NameAttribute value
MakerLittelfuse
Product CategoryIndustrial current sensors
Shipping restrictionsThis product may require additional documentation for export from the United States.
Current rating50 A
sensor typeClosed Loop
Response time2 s
Frequency Range45 Hz to 500 Hz
high44.5 mm
Insulation voltage2500 V
length88.9 mm
EncapsulationBulk
seriesECS
width63.5 mm
Maximum operating temperature+ 60 C
Minimum operating temperature- 40 C
Working power voltage120 VAC
Factory packaging quantity1
unit weight181.437 g
Protection Relays
Current Monitoring Relays and Transducers
ECS SERIES
Current Sensors
Description
The ECS Series of single-phase AC current sensors is a universal,
overcurrent or undercurrent sensing control. Its built-in toroidal
sensor eliminates the inconvenience of installing a stand-alone
current transformer. Includes onboard adjustments for current
sensing mode, trip point, and trip delay. Detects over or
undercurrent events like locked rotor, loss of load, an open heater
or lamp load, or proves an operation is taking place or has ended.
Operation
Input voltage must be supplied at all times for proper operation.
When a fault is sensed throughout the trip delay, the output
relay is energized. When the current returns to the normal run
condition or zero, the output and the delay are reset. If a fault is
sensed and then corrected before the trip delay is completed,
the relay will not energize and the trip delay is reset to zero.
Adjustment
Select the desired function, over or under current sensing.
Set the trip point and trip delay to approximate settings. Apply
power to the ECS and the monitored load. Turn adjustment and
watch the LED. LED will light; turn slightly in opposite direction
until LED is off. Adjustment can be done while connected to the
control circuitry if the trip delay is set at maximum. To increase
sensitivity, multiple turns may be made through the ECS’s
toroidal sensor. The appropriate trip point range is determined by
multiplying the amperage load by the number of turns/passes
through the toroidal sensor. When using an external CT, select
a 2VA, 0-5A output CT rated for the current to be monitored.
Select ECS adjustment range 0. Pass one secondary wire
lead through the ECS toroid and connect the secondary leads
together.
Wiring Diagram
V = Voltage
I> = Overcurrent
I< = Undercurrent
W = Insulated Wire Carrying
Monitored Current
Relay contacts are isolated.
Arrow on the toroid points
toward the load.
Features & Benefits
FEATURES
Built-in toroidal
current sensing
Encapsulated
Adjustable mode, trip
point and trip delay
BENEFITS
Eliminates need to install stand-alone
current transformer and provides isolation from
monitored circuit
Protects against shock, vibration, and humidity
Provides flexibility for use in many applications
Allows control of AC voltage loads
Ordering Information
See next page.
10A, SPDT isolated
relay output
Accessories
P1015-13
(AWG 10/12),
P1015-64
(AWG 14/16),
P1015-14
(AWG 18/22)
Female Quick Connect
These 0.25 in. (6.35 mm) female terminals are
constructed with an insulator barrel to provide
strain relief.
© 2018 Littelfuse Protection Relays & Controls
www.littelfuse.com/ecs
www.littelfuse.com/
Rev: 1-A-062716
1-A-101218

ECSH4HF.08D Related Products

ECSH4HF.08D ECSH21F2.5C ECS31AC ECSH3HF0.08D ECSH31F.08D ECSH41F.08D ECSH34F.08C
Description Industrial current sensor 120VAC ISOLATED SPDT CURRENT SENSOR Industrial current sensor 24VAC ISOLATED SPDT CURRENT SENSOR Industrial current sensor 24VDC ISOLATED SPDT CURRENT SENSOR Industrial current sensor 24VDC ISOLATED SPDT CURRENT SENSOR Industrial current sensor CURRENTSENSOR Industrial current sensor 120VAC ISOLATED SPDT CURRENT SENSOR Industrial current sensor 24VDC ISOLATED SPDT CURRENT SENSOR
Maker Littelfuse Littelfuse Littelfuse Littelfuse Littelfuse Littelfuse Littelfuse
Product Category Industrial current sensors Industrial current sensors Industrial current sensors Industrial current sensors Industrial current sensors Industrial current sensors Industrial current sensors
Current rating 50 A 20 A 20 A 50 A 20 A 20 A 4 A
sensor type Closed Loop Closed Loop Closed Loop Closed Loop Closed Loop Closed Loop Closed Loop
Response time 2 s 1 s 7 s 2 s 2 s 2 s 1 s
Frequency Range 45 Hz to 500 Hz 45 Hz to 500 Hz 45 Hz to 500 Hz 45 Hz to 500 Hz 45 Hz to 500 Hz 45 Hz to 500 Hz 45 Hz to 500 Hz
high 44.5 mm 44.5 mm 44.5 mm 44.5 mm 44.5 mm 44.5 mm 44.5 mm
Insulation voltage 2500 V 2500 V 2500 V 2500 V 2500 V 2500 V 2500 V
length 88.9 mm 88.9 mm 88.9 mm 88.9 mm 88.9 mm 88.9 mm 88.9 mm
Encapsulation Bulk Bulk Bulk Bulk Bulk Bulk Bulk
series ECS ECS ECS ECS ECS ECS ECS
width 63.5 mm 63.5 mm 63.5 mm 63.5 mm 63.5 mm 63.5 mm 63.5 mm
Maximum operating temperature + 60 C + 60 C + 60 C + 60 C + 60 C + 60 C + 60 C
Minimum operating temperature - 40 C - 40 C - 40 C - 40 C - 40 C - 40 C - 40 C
Working power voltage 120 VAC 24 VDC 120 VAC 24 VDC 24 VDC 120 VAC 24 VDC
Factory packaging quantity 1 1 1 1 1 1 1
unit weight 181.437 g 181.437 g 181.437 g 181.437 g 181.437 g 181.437 g 181.437 g
Shipping restrictions This product may require additional documentation for export from the United States. This product may require additional documentation for export from the United States. This product may require additional documentation for export from the United States. - - This product may require additional documentation for export from the United States. -
Does anyone have information on PTZ decoders?
Does anyone have information on PTZ decoders?...
aluoqiang Embedded System
TEAMWORK
...
890 Talking
Live FAQ|Typical applications in the era of the Internet of Things
Live broadcast details: It is coming, typical applications in the era of the Internet of ThingsLive Topic 1: Low-power MCU in simple terms Live lecturer: Duan WeiLive Topic 2: 5G Accelerates IoT Appli...
EEWORLD社区 MCU
How to switch input method by key control?
Hello everyone: At present, my PDA has a soft keyboard and a Hanwang handwriting input method. By default, they are both in the taskbar and can be selected by clicking on the touch screen. But now I w...
ilycjf Embedded System
EEWORLD University ---- nxp
nxp:https://training.eeworld.com.cn/course/4138...
w562601331 MCU
DC Circuit Analysis
T(℃)↑→IC↑→UE↑→UBE↓(UB basically unchanged)→ IB↓→ IC↓ IB decreases, I don't understandSome people say it is a characteristic of triodes. I don't understand. I can't seem to find this characteristic in ...
nt06 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1530  2181  2134  1767  2765  31  44  43  36  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号