QPC6082
GENERAL PURPOSE SP8T SWITCH
Product Overview
The QPC6082 is a low loss, high isolation SP8T switch with
performance optimized for CDMA, WCDMA & LTE
applications requiring high linearity
The RF and antenna ports can be directly connected in
50 systems and control logic is compatible with +1.3 V to
+1.8V systems. DC blocking caps are not required if there
is no external DC voltage present at the RF or antenna
ports. The supply voltage is intended for connection to
+2.85 V systems but the device is operable from +2.4 V to
+4.5 V.
The standard 14 pad QFN package and compact 2.0 mm x
2.0 mm size offers designers a compact, easy-to-use,
switch component for quick integration into multimode,
multi-band systems.
14 Pad 2.0 mm x 2.0 mm x 0.55 mm QFN Package
Key Features
•
Very Low Insertion Loss: 0.4 dB typ. In Band 5
•
High Port-to-Port Isolation: 31 dB typ. In Band 5
•
Power Handling up to +32 dBm into 50
•
GPIO Interface for +1.3 V to +1.8 V Control Logic
•
Multi-Band Operation 700 MHz to 2700 MHz
•
Compact 2.0 mm x 2.0 mm QFN Package
•
No DC Blocking Capacitors Required
(unless external DC is applied to the RF ports)
Functional Block Diagram
Applications
•
Data Cards
•
IoT
•
Telemetry
•
Automotive
•
Cellular Modems and USB Devices
•
Multi-Mode WCDMA, LTE Applications
Ordering Information
Top View
Part No.
QPC6082
QPC6082SB
QPC6082SQ
QPC6082SR
QPC6082TR7
QPC6082PCK401
Description
SP8T Switch for 3G/4G
Sample Bag with 5 pieces
Sample Bag with 25 pieces
Sample Reel with 100 pieces
2500-PC Taped on 13” Reel Fully
Assembled EVB + 5 Piece Sample Bag
Data Sheet August 26
th
, 2016 | Subject to change without notice
1 of 11
www.qorvo.com
QPC6082
GENERAL PURPOSE SP8T SWITCH
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Maximum V
DD
Maximum V
CTRL
Max Input Power
(Momentary Infrequent
Occurrence)
Max Input Power
(Continuous Operation)
1:1 VSWR, +25°
C
6:1 VSWR, +25°
C
1:1 VSWR, +25°
C
6:1 VSWR, +25°
C
Recommended Operating Conditions
Rating
−40 to +125 °
C
−30 to +90 °
C
+6.0 V
+3.0 V
+38.5 dBm
+35.0 dBm
+36.5 dBm
+35.5 dBm
Parameter
Device Voltage (V
DD
)
V
DD
Supply Current
C
TL1,2,3
Logic Low Voltage
C
TL1,2,3
Logic High Voltage
(1)
C
TL1,2,3
Logic High Current
Switching Time
(2)
Turn-On Time
(3)
Min
+2.4
-
0.00
+1.3
-
Typ
+2.85
80
-
-
Max
+4.5
120
+0.45
+2.7
5
2
Units
V
µA
V
V
µA
µs
µs
4
Exceeding any one or a combination of the Absolute Maximum Rating
conditions may cause permanent damage to the device. Extended
application of Absolute Maximum Rating conditions to the device may
reduce device reliability.
Electrical specifications are measured at specified test conditions.
Specifications are not guaranteed over all recommended operating
conditions.
Notes:
1. V
DD
must be > V
CTRL
at all times.
2. 10% to 90% RF.
3. 3. Time from VDD=0V to part ON and RF at 90%.
Electrical Specifications
Parameter
Conditions
(1)
704 – 787 MHz
815 – 960 MHz
Insertion Loss RFX to ANT
1710 – 1980 MHz
2110 – 2170 MHz
2300 – 2690 MHz
Low Band, 2fo
Low Band, 3fo
Harmonics
High Band, 2fo
High Band, 3fo
High Band, 2fo
High Band, 3fo
Low Band
Input IP2
High Band
Pin = +28 dBm, 50
fo=824 MHz
fo=824 MHz
fo=1980 MHz
fo=1980 MHz
fo=2570 MHz
fo=2570 MHz
TX Carrier at 897.5 MHz at +21 dBm
CW Blocker at 1840 MHz at -15 dBm
Measured RX frequency = 942.5 MHz
TX Carrier at 1880 MHz at +21 dBm
CW Blocker at 3840 MHz at −15 dBm
Measured RX frequency = −1960 MHz
TX Carrier at 897.5 MHz at +21 dBm
CW Blocker at 1840 MHz at −15 dBm
Measured RX frequency = 942.5 MHz
TX Carrier at 1880 MHz at +21 dBm
CW Blocker at 3840 MHz at −15 dBm
Measured RX frequency = 1960 MHz
VSWR=2:1, BC0/BC1/BC4/BC5/BC14/BC15
704 – 2690 MHz
Min
-
-
-
-
-
-
-
-
-
-
-
113
Typ
0.40
0.40
0.50
0.66
0.76
-115
-84
-99
-82
-92
-79
117
Max
0.55
0.55
0.70
0.79
0.90
-96
-81
-86
-76
-88
-75
-
Units
dB
dBc
dB
115
118
-
dB
Low Band
Input IP3
High Band
Triple Beat Ratio
VSWR
66
68
-
dB
67
81
-
69
-
1.1:1
-
-
1.5:1
dB
dBc
-
Notes:
1. Test conditions unless otherwise stated: all unused RF ports terminated in 50 , Input and Output = 50 , Temp. = +25 ° V
DD
= +2.85V, V
CTRL
C,
High = +1.8 V, V
CTRL
Low = 0 V
Data Sheet August 26
th
, 2016 | Subject to change without notice
2 of 11
www.qorvo.com
QPC6082
GENERAL PURPOSE SP8T SWITCH
Electrical Specifications
(1)
– Isolation Matrix – 704 MHz to 960 MHz
Values Min/Typ (dB)
RF1
RF2
RF3
RF4
RF5
RF6
RF7
RF8
RF1
-
-
-
-
-
-
-
-
RF2
35 / 43
-
-
-
-
-
-
-
RF3
36 / 44
30 / 33
-
-
-
-
-
-
RF4
36 / 48
38 / 43
30 / 32
-
-
-
-
-
RF5
39 / 42
37 / 46
36 / 40
36 / 43
-
-
-
-
RF6
38 / 46
43 / 46
41 / 47
40 / 47
34 / 43
-
-
-
RF7
37 / 44
41 / 46
41 / 43
39 / 43
36 / 48
31 / 33
-
-
RF8
37 / 43
40 / 46
40 / 43
39 / 41
36 / 45
38 / 40
29 / 31
-
ANT
(2)
31 / 34
31 / 44
31 / 43
30 / 42
30 / 33
35 / 44
33 / 41
33 / 42
Notes:
1. Test conditions unless otherwise stated: all unused RF ports terminated in 50 , Input and Output = 50 , Temp. = +25 ° V
DD
= +2.85V, V
CTRL
C,
High = +1.8 V, V
CTRL
Low = 0 V.
2. RFx path not selected.
Electrical Specifications
(1)
– Isolation Matrix – 1710 MHz to 2170 MHz
Values Min/Typ (dB)
RF1
RF2
RF3
RF4
RF5
RF6
RF7
RF8
RF1
-
-
-
-
-
-
-
-
RF2
27 / 31
-
-
-
-
-
-
-
RF3
29 / 31
21 / 23
-
-
-
-
-
-
RF4
29 / 35
27 / 30
21 / 23
-
-
-
-
-
RF5
28 / 30
29 / 30
29 / 31
29 / 31
-
-
-
-
RF6
29 / 32
30 / 33
29 / 33
28 / 33
27 / 31
-
-
-
RF7
29 / 31
29 / 33
29 / 31
26 / 31
29 / 34
22 / 24
-
-
RF8
29 / 31
28 / 31
28 / 31
27 / 29
29 / 35
27 / 31
20 / 22
-
ANT
(2)
21 / 25
26 / 32
26 / 32
26 / 31
21 / 25
27 / 31
26 / 32
25 / 31
Notes:
1. Test conditions unless otherwise stated: all unused RF ports terminated in 50 , Input and Output = 50 , Temp. = +25 ° V
DD
= +2.85V, V
CTRL
C,
High = +1.8 V, V
CTRL
Low = 0 V.
2. RFx path not selected.
Electrical Specifications
(1)
– Isolation Matrix – 2300 MHz to 2690 MHz
Values Min/Typ (dB)
RF1
RF2
RF3
RF4
RF5
RF6
RF7
RF8
RF1
-
-
-
-
-
-
-
-
RF2
25 / 27
-
-
-
-
-
-
-
RF3
27 / 30
18 / 20
-
-
-
-
-
-
RF4
27 / 31
24 / 27
18 / 20
-
-
-
-
-
RF5
25 / 27
26 / 29
26 / 28
26 / 28
-
-
-
-
RF6
27 / 29
28 / 29
29 / 29
25 / 29
25 / 27
-
-
-
RF7
26 / 28
26 / 29
26 / 25
25 / 27
27 / 30
20 / 21
-
-
RF8
26 / 28
25 / 28
25 / 27
25 / 27
27 / 30
24 / 27
18 / 19
-
ANT
(2)
18 / 20
24 / 29
24 / 28
24 / 28
19 / 21
24 / 29
24 / 28
23 / 28
Notes:
1. Test conditions unless otherwise stated: all unused RF ports terminated in 50 , Input and Output = 50 , Temp. = +25 ° V
DD
= +2.85V, V
CTRL
C,
High = +1.8 V, V
CTRL
Low = 0 V.
2. RFx path not selected.
Data Sheet August 26
th
, 2016 | Subject to change without notice
3 of 11
www.qorvo.com
QPC6082
GENERAL PURPOSE SP8T SWITCH
Control Logic
Mode (Signal Path)
RF1 – ANT
RF2 – ANT
RF3 – ANT
RF4 – ANT
RF5 – ANT
RF6 – ANT
RF7 – ANT
RF8 – ANT
CTL1
High
Low
High
Low
High
Low
High
Low
CTL2
Low
High
High
Low
Low
High
High
Low
CTL3
Low
Low
Low
High
High
High
High
Low
NOTE: The SP8T switch is controlled by CTL1, CTL2, and CTL3.
Recommended Operating Power, 50
Frequency
8 MHz
20 MHz to 100MHz
500MHz – 3GHz
4GHz
System
Theta-J(°C/W)
236
110
55
57
+30 dBm
+31.5 dBm
+32dBm
+31dBm
Power at T=+85
°C
+30 dBm
+34.5dBm
+36dBm
+35dBm
Power at T=+105
°C
Data Sheet August 26
th
, 2016 | Subject to change without notice
4 of 11
www.qorvo.com
QPC6082
GENERAL PURPOSE SP8T SWITCH
Performance Plots
Test conditions unless otherwise noted: V
DD
= +2.85 V
Insertion Loss vs. Frequency over Temperature
0.0
Switch Path: RFC(ANT) to RF3
Measured RF3 to RFC(ANT)
Insertion Loss vs. Frequency
0.0
Switch Path: RFC(ANT) to RFX
Measured RFX to RFC(ANT)
-0.5
-0.5
Temp.=+25 °
C
-1.0
+105 °C
-1.0
|S21| (dB)
|S21| (dB)
-1.5
+85 °C
+25 °C
−40 °C
RF1
-1.5
RF2
RF3
RF4
RF5
RF6
RF7
RF8
-2.0
-2.0
-2.5
-2.5
-3.0
0
1
2
3
4
5
6
-3.0
0
1
2
3
4
5
6
Frequency (GHz)
Frequency (GHz)
RF3 Return Loss vs. Frequency over Temperature
0
Signal Path: RF3 to RFC(ANT)
Measured at RF3 Port
RFX Return Loss vs. Frequency
0
Signal Path: RFC(ANT) to RFX
Measured at RFX Ports
Temp.=+25 °C
-10
-10
|S11| (dB)
+85 °C
+25 °C
−40 °C
|S11| (dB)
-20
+105 °
C
-20
RF1
RF2
-30
-30
RF3
RF4
RF5
-40
-40
RF6
RF7
RF8
-50
0
1
2
3
4
5
6
-50
0
1
2
3
4
5
6
Frequency (GHz)
Frequency (GHz)
RFC Return Loss vs. Frequency over Temperature
0
Signal Path: RFC (ANT) to RF3
Measured at RFC (ANT)
RFC Return Loss vs. Frequency
0
Signal Path: RFC(ANT) to RFX
Measured at RFC(ANT) Port
Temp.=+25 °C
-10
-10
|S11| (dB)
|S11| (dB)
-20
+105 °
C
-20
RF1 ON
RF2 ON
-30
+85 °C
+25 °C
−40 °C
-30
RF3 ON
RF4 ON
RF5 ON
-40
-40
RF6 ON
RF7 ON
RF8 ON
-50
0
1
2
3
4
5
6
-50
0
1
2
3
4
5
6
Frequency (GHz)
Frequency (GHz)
Data Sheet August 26
th
, 2016 | Subject to change without notice
5 of 11
www.qorvo.com