EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/S501-4-R

Description
SMALL DIM. FUSE
CategoryCircuit protection    The fuse    The fuse tube   
File Size809KB,2 Pages
ManufacturerBussmann (Eaton)
Environmental Compliance
Download Datasheet Parametric View All

BK/S501-4-R Overview

SMALL DIM. FUSE

BK/S501-4-R Parametric

Parameter NameAttribute value
MakerBussmann (Eaton)
Product Categoryfuse tube
Shipping restrictionsMouser does not currently sell this product.
seriesS501
productCeramic Fuse
Current rating4 A
Fuse typeFast Blow
Fuse size/group5 mm x 20 mm
Voltage ratingAC250 VAC
interrupt rating1.5 kA
Installation styleHolder / Clip
Termination typeClip
EncapsulationBulk
resistance27 mOhms
Subject typeCylindrical
diameter5.2 mm
Indicator typeWithout Indicator
length20 mm
Factory packaging quantity100
unit weight1.070 g
Technical Data
2051
Effective
June
2017
Supersedes
March
2011
S501
5 mm x 20 mm Fast-acting ceramic tube fuses
Agency information
cURus: File E19180, Guide JDYX2, JDYX8
CSA Component Acceptance: File 53787
SEMKO Approval: File 413779
VDE Approval: File 40015517
IMQ Approval: File EB405
CCC Approval: File 2005010207155691
BSI Approval: File KM55676
Product features
Fast-acting high breaking capacity
Optional axial leads available
5 mm x 20 mm physical size
Ceramic tube with silver-plated (50 mA-400 mA) and
nickel-plated (500 mA-10 A) endcaps.
Designed to IEC 60127-2
Ordering
information
Specify packaging, product and option code
Ratings above 6.3 A have a 0.8 mm diameter lead
With TR2 packaging code, lead wire length is 19.05 mm
In
50mA-4A
5A-6.3A
8A-10A
Electrical Characteristics
1.5 In 2.1 In
2.75 In
4 In
min
max
min
max
min
max
60 min 30 min 10 ms 2 sec 3 ms 300 ms
60 min 30 min 10 ms 3 sec 3 ms 300 ms
30 min 30 min 40 ms 20 sec 10 ms
1s
10 In
max
20 ms
20 ms
30 ms
Product
Code
S501-50-R
S501-63-R
S501-80-R
S501-100-R
S501-125-R
S501-160-R
S501-200-R
S501-250-R
S501-315-R
S501-400-R
S501-500-R
S501-630-R
S501-800-R
S501-1-R
S501-1.25-R
S501-1.6-R
S501-2-R
S501-2.5-R
S501-3.15-R
S501-4-R
S501-5-R
S501-6.3-R
S501-8-R
S501-10-R
Voltage Interrupting Rating at
Rating Rated Voltage (50Hz)
Vac
Vac
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
250
1500
Typical DC
Cold Resistance
(Ω)*
157.5
39.0
27.9
20.0
12.3
8.5
6.0
4.4
3.3
2.2
0.460
0.340
0.245
0.231
0.176
0.113
0.073
0.053
0.037
0.027
0.019
0.014
0.009
0.008
Specifications
Typical
Typical
Melting I
2
t Voltage
(amps)
Drop (mV)†
0.0017
9000
0.0005
3300
0.0011
2600
0.0018
2300
0.0037
1900
0.008
1600
0.02
1350
0.027
1300
0.01
1400
0.018
1200
0.038
1050
0.064
1200
0.097
490
0.146**
330
0.313**
297
0.748**
239
2.0
205
3.9
190
8.1
160
14
160
25
155
48
150
104
102
155
111
Agency Approvals
IMQ VDE BSI SEMKO cURus
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CCC
X
X
MITI/
JET
CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X‡
X‡
X‡
X‡
X‡
X
X
X
* DC Cold Resistance (measured at <10% of rated current)
** I
2
t of 1A, 1.25A & 1.6A is measured at 10I
n DC
† Typical Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current)
‡ CSA approvals on these ratings will not be marked on the fuse cap
A little calculation problem, I don't understand
Hello everyone! My level is limited. As shown in the figure, e=2.71828 1.81V, how do you calculate it? It's the 1-e in the brackets... I don't understand the rest! Thank you...
wzk198005 Analog electronics
51 System design error
I have uploaded the proteus simulation circuit and program. The program can be compiled, but there is no movement during simulation. Please contact tangangsl@163.com QQ:522601416 Thank you....
ngangsl 51mcu
Epileptic EEG Signal Processing Based on DSP
1 Introduction The diagnosis of epilepsy mainly relies on clinical history, and electroencephalogram (EEG) examination can be used as a valuable auxiliary diagnostic tool. According to statistics, abo...
dtcxn Medical Electronics
IAR FOR MSP430 V7 simulation problem, please solve
Hey guys, I just changed from WIN7 to WIN10. The previous IAR for MSP430 V5.20 can't be used on WIN10. I installed V7.10, and V7.20 has problems when emulating. Please help me analyze it, I'd be very ...
清风84 TI Technology Forum
LM3S811 Schematic Library
Use SCH...
蓝雨夜 Microcontroller MCU
IR2104 drive circuit HO no waveform
In the PWM drive circuit, the HO outputs a DC signal, and there is no way to use the duty cycle to adjust the voltage reduction. Can you guys help me check if my circuit is connected correctly?...
Lever Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 419  2499  2679  1010  1963  9  51  54  21  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号