Today More Than Ever,
DeviceNet Continues
Support for Machine Automation Controller NJ-Series!
Support for open network
The MX2 series/ MX2 series V1 type/
RX series V1 type* can be
connected to DeviceNet by mounting
the Communications Unit.
* Supported for the MX2 series Ver.1.1 or higher.
Not Supported for the RX series without V1 type.
8 types of remote I/O higher functions
8 types of remote I/O functions that
exchange I/O data automatically
without program are provided.
All of the following functions of the inverter
can also be used.
- Simple positioning control
- Torque control
- Setting of acceleration/deceleration time etc.
Parameter Edit via DeviceNet
Parameters of the inverter can be
edited via DeviceNet communication
by using CX-Drive*,
support tool of inverter/servo drive.
No tool switching required.
* Supported for CX-Drive Ver.2.6 or higher.
MX2 series V1 type
DeviceNet
Communication Unit
RX series V1 type
DeviceNet
Communication Unit
3G3AX-MX2-DRT-E
P. 109
3G3AX-RX-DRT-E
P. 110
F-2
Intelligent Slaves (PLC Units)
Overview
Introducing DeviceNet Products
Network Specifications
F-4
F-12
F-19
Programmable Slaves (CPM2C-S1@OC-DRT)
88
Intelligent Slaves
Digital Sensor Communications Unit
(E3X-DRT21-S VER.3 )
DeviceNet ID Slave (V600-HAM42-DRT)
DeviceNet ID Slave (V680-HAM42-DRT)
92
94
95
96
100
104
CJ-series DeviceNet Unit (CJ1W-DRM21)
CS-series DeviceNet Unit (CS1W-DRM21-V1)
Programmable Controller NSJ Series
(NSJ@-T@@1(B)-G5D)
DeviceNet Board (PCI Board) (3G8F7-DRM21)
2
3
4
7
Smart Slaves DRT2 Series
DRT2-series Smart Slaves
Smart Slaves DRT2 Series
Transistor Remote I/O Terminals
(DRT2-@D08(-1)/@D16(-1))
Expansion Units
(XWT-ID08(-1)/OD08(-1)/ID16(-1)/OD16(-1))
Remote I/O Terminal with Relay Outputs (DRT2-ROS16)
Transistor Remote I/O Terminals with 3-tier
Terminal Blocks (DRT2-@D16TA(-1))
e-CON Connector Terminals (DRT2-@D16S(-1))
MIL Connector Terminals (with Transistor)
(DRT2-@D32ML(-1)/@D16ML(-1))
Board Terminals with MIL Connector
(DRT2-@D32B(-1)/@D32BV(-1))
Screw-less Clamp Terminals with Transistors
(DRT2-@D16SL(H)(-1)/@D32SLH(H)(-1))
Environment-resistive Terminals with Transistors (High-function Type)
(DRT2-@D08C(-1)/@D16C(-1))
Environment-resistive Terminals with Transistors (Standard type)
(DRT2-@D04CL(-1)/@D08CL(-1)/@D16CL(-1))
Analog I/O Terminals (DRT2-AD04(H)/DA02)
Temperature Input Terminals (DRT2-TS04@)
9
10
18
22
26
28
31
34
39
43
48
51
57
60
64
68
70
72
73
CIP Safety on DeviceNet System
Safety Network Controller NE0A-SCPU01
Safety Network Controller NE1A-SCPU Series
Safety I/O Terminal DST1 Series
Network Configurator WS02-CFSC1-E
111
112
117
122
125
Configurator and Software
DeviceNet Configurator Ver.2.@ WS02-CFDC1-E
DeviceNet Configurator PC Card (Software Included)
3G8E2-DRM21-V1
DeviceNet Analyzer WS02-ALDC1
NX-Server WS02-NX@C1
Device Inspector WS02-DIPC1
127
128
128
130
131
132
Peripheral Devices
General-purpose Peripheral Devices
Peripheral Devices for Environment-resistive Slaves
133
134
144
Ordering Information
Ordering Information
159
160
SmartSlice GRT1 Series
SmartSlice GRT1 Series
DeviceNet Communications Unit (GRT1-DRT)
SmartSlice I/O Units
Information
Related Manuals
Introduction of the Switch Mode Power Supply
175
176
177
MULTIPLE I/O TERMINAL Series
MULTIPLE I/O TERMINAL Series
Communications Unit (DRT1-COM)
Digital I/O Units
(GT1-@D16(-1)/@D16MX(-1)/@D16ML(-1)/
@D32ML(-1)/@D16DS(-1))
Relay Output Units (GT1-ROS16/ROP08/FOP08)
Analog I/O Units (GT1-AD/DA)
Temperature Input Unit (GT1-TS04@)
74
81
83
85
Windows is registered trademarks of Microsoft Corporation in the USA and other countries.
DeviceNet
TM
, EtherNet/IP
TM
, CompoNet
TM
and CIP Safety
TM
are the trademarks of ODVA.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
F-3
Ordering
Information
Peripheral
Devices
Configurator
and Software
CIP Safety on
DeviceNet System
Intelligent
Slaves
MULTIPLE I/O
TERMINAL Series
SmartSlice
GRT1 Series
DeviceNet-compliant Digital Indicator (K3HB-@-DRT)
DeviceNet -compliant Digital Controllers (E5AR-DRT/E5ER-DRT)
DeviceNet Communications Unit for Modular Temperature Controllers (EJ1-DRT)
Multi-function Compact Inverter MX2-Series V1 type DeviceNet Communication Unit
107
3G3AX-MX2-DRT-E
High-function General-purpose Inverter RX-Series V1 type DeviceNet Communication Unit
108
3G3AX-RX-DRT-E
DRT2-series
Smart Slaves
Master
Units
Master Units
1
Introducing
Network
Specifications DeviceNet Products
Selecting a Network Is a Strategic Decision.
to Evolve.
Overview
Linking the World. A Global Open Network
Greater Wiring Reduction, Standardization,
on a Global Scale.
What Is DeviceNet?
DeviceNet is a field network that easily performs
mutual connections between control devices, such as
PLCs, computers, and sensors, as well as data
devices, such as barcode readers and RFID Systems.
DeviceNet is a standardized network that enables
intelligent control of field devices and improves
system productivity.
Information level
Controller level
Ethernet/IP
Device level
DeviceNet
Sensor & Actuator level
CompoNet
Easy and
flexible
wiring and
layout
High-speed
response
Noise
resistance
DeviceNet
Features
Standardization
Global
standard
Enhanced
safety
Simple
maintenance
F-4
Superior installation performance enables easy
and flexible wiring and layout.
DeviceNet covers a wide array of FA applications, ranging from the sensor or
device level to the controller level. With its superior installation performance,
DeviceNet easily achieves mutual connections between sensors and other
control devices in one network as well as reducing costs and shortening lead
time in many aspects of manufacturing, ranging from design and manufacture
of equipment and lines to installation, operation, and maintenance.
Trunk line length (100 m: 500 kbps; 250 m: 250 kbps; or 500 m: 125 kbps)
24-VDC power supply for network
Terminating
resistance
Multidrop
Tap
(Branch line length: 6 m max.)
Tap
Tap
Tap
Tap
Terminating
resistance
Device
Tap
Device
Device
Device
Device
Device
Device
Device
T-branch
Device
Device
Device
Device
Star connections
Accelerating the Global Standardizations Required
by Industry in This Age of Global Manufacturing
DeviceNet has been the leader in standardization required for this age of
borderless manufacturing as a standard for a variety of countries and
industrial organizations, such as with standard sensor bus certification by the
SEMI industrial association and compliance with IEC, an international global
standard. Equipment and lines at manufacturing sites overseas can be
constructed and operated in the same way as at sites in Japan without the
need for training on wiring rules or detailed explanations.
SEMI
E54.4-0997
11898
GB T18858.2-2002
Support for Creating Maintenance and Safety
Systems
Suppor t is provided for creating maintenance systems that provide
failure prediction as preventive maintenance to reduce equipment
downtime, which is a constant issue at manufacturing sites.
Page F-6
Using DeviceNet lets you create safety control networks and program logic.
Monitoring with safety controls makes maintenance easier.
Page F-8
F-5
Ordering
Information
ISO
CENELEC
EN50325-2
Peripheral
Devices
62026-3
Configurator
and Software
IEC
CIP Safety on
DeviceNet System
Intelligent
Slaves
MULTIPLE I/O
TERMINAL Series
Branching to
branch lines
SmartSlice
GRT1 Series
DRT2-series
Smart Slaves
Master
Units
Introducing
Network
Specifications DeviceNet Products
Overview
Used Worldwide.
and IT Technology at Manufacturing Sites