EEWORLDEEWORLDEEWORLD

Part Number

Search

SCC1-Analog 10m

Description
Analog Sensor Cable
CategoryWire/cable    Cable package    Sensor/actuator cable   
File Size596KB,8 Pages
ManufacturerSensirion
Environmental Compliance
Download Datasheet Parametric Compare View All

SCC1-Analog 10m Overview

Analog Sensor Cable

SCC1-Analog 10m Parametric

Parameter NameAttribute value
MakerSensirion
Product CategorySensor cable/actuator cable
Shipping restrictionsMouser does not currently sell this product.
seriesSCC1
EncapsulationBulk
Factory packaging quantity3
Datasheet
Analog Sensor Cable
SCC1-Analog
Configurable analog voltage output of flow rate
Switch output with configurable threshold
Volume integration by counting pulses
Applicable to digital SLQ, SLI, SLS and
SLG liquid flow meters
Product Summary
The Analog Sensor Cable SCC1-Analog allows
simple and quick readout of Sensirion’s liquid flow
meters by converting the digital sensor reading to
an analog voltage output configurable to any range
within 0-10.5V. Additionally, a digital (high/low)
output with two modes of operation is available
(Flow Switch / Volume Counter).
Connecting the SCC1-Analog
One side of the SCC1-Analog is connected to the
4-Pin M8 connector of Sensirion’s liquid flow meters.
The other side has four wires: Two for power supply
and one for each output (analog and digital output).
The outputs should be measured as indicated in the
block diagram of Fig. 7.
The interface electronics are molded into the cable.
The cable is available in two length variants with a
total length of 2 meters and 10 meters, respectively.
Wire Assignment
Wire
Blue
White
Brown
Black
Function
Supply voltage
Ground
Analog output
Digital output
Symbol
V
supp
GND
AOut
DOut
Fig. 1: SCC1-Analog connected to flow meter.
In
Flow Switch
mode, the output is high or low
depending on the momentary flow rate and two
configurable threshold values.
In
Volume Counter
mode, a voltage pulse is
generated every time a defined volume has flown
through the flow meter.
Analog Output (AOut)
The analog output provides a voltage which
corresponds to the measured flow rate. The flow rate
is linearly mapped to the voltage across a user-
specified range, see Fig. 2, and can be calculated by
the following formula:
WARNING!
Incorrect connection may lead to permanent damage
of the cable. Check the wire assignment carefully.
The parameters Vmax, flow
atVmax
and flow
at0V
can be
configured by the user (see section
Configuration).
They can be freely chosen in the range of the
sensor’s specifications (see appendix).
By default, SCC1-Analog is set with 5 V output at
no-flow, 0 V for negative max flow, and 10 V for
positive max flow. Refer to appendix for max flow
www.sensirion.com
Version 4 – April 2016
1/7

SCC1-Analog 10m Related Products

SCC1-Analog 10m SCC1-Analog 2m
Description Analog Sensor Cable Analog Sensor Cable
Maker Sensirion Sensirion
Product Category Sensor cable/actuator cable Sensor cable/actuator cable
Shipping restrictions Mouser does not currently sell this product. Mouser does not currently sell this product.
series SCC1 SCC1
Encapsulation Bulk Bulk
Factory packaging quantity 3 5
wince multi serial port communication
We are working on a subway project and need to develop a gateway that needs 10 serial ports for independent data communication. We plan to use WinCE embedded development, but the current chip does not...
fdds Embedded System
The board cannot be recognized by ISE!!
Hi, I am a beginner in FPGA. I am using Spartan-3E board and I want to use impact to download the program, but the board cannot be recognized. There is no unkown bypass. I use JTAG port mode and I hav...
xiamingwudi FPGA/CPLD
TTL to serial port voltage
[font=Tahoma][size=3]I have a touch screen used in industrial control, which has a built-in RS232 serial port for communication. The tx pin is about -7.2v, and the rx pin is about 0.5v. [/size][/font]...
song430 Power technology
DDS peripheral circuit design and program based on AD9854
DDS peripheral circuit design and program based on AD9854...
风亦路 51mcu
Segment LCD Consulting
Hello everyone: I would like to know the cost of making a segment LCD mold, and what is the unit price? Which friend knows this information and can help provide it? Thank you in advance!...
chenzhouyu Analog electronics
Looking for arm Chinese simulator
I made an ARM Chinese simulator according to the method provided on the Internet, but I can't deploy it. Who can provide a PB5.0 ARM Chinese simulator? My email: swj9711@163.com...
春暖花开 ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 474  2245  1076  2182  2607  10  46  22  44  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号