Fluid connection type
Electrical connection
AWG gauge
Cable entry
Contacts type and com-
position
Product specific applica-
tion
Pressure switch type of
operation
Electrical circuit type
Scale type
Local display
Adjustable range of
switching point on rising
pressure
Adjustable range of
switching point on falling
pressure
Possible differential
maximum at high setting
Maximum permissible
accidental pressure
Destruction pressure
Pressure actuator
Materials in contact with
fluid
Enclosure material
[In] rated current
AWG 20...AWG 14
0.2...2.32 bar
1.25 bar
37.5 bar
67.5 bar
Diaphragm
FPM, FKM
Steel
Zinc alloy
3 A, B300, AC-15 (Ue = 120 V) conforming to EN/
IEC 60947-5-1
1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/
IEC 60947-5-1
0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/
IEC 60947-5-1
Complementary
Possible differential minimum at low setting
Possible differential minimum at high setting
Maximum permissible pressure - per cycle
Terminal block type
Operating rate
Repeat accuracy
0.1 bar (+/- 0.02 bar)
0.18 bar (+/- 0.03 bar)
30 bar
8 terminals
120 cyc/mn
<2%
Dec 3, 2018
1
[Ui] rated insulation voltage
300 V conforming to CSA C22.2 No 14
500 V conforming to EN/IEC 60947-1
300 V conforming to UL 508
6 kV conforming to EN/IEC 60947-1
Simultaneous, snap action
Silver contacts
< 25 mOhm conforming to IEC 255-7 category 3
< 25 mOhm conforming to NF C 93-050 method A
10 A cartridge fuse type gG (gl)
2000000 cycles
External
113 mm
85 mm
46 mm
3.5 kg
[Uimp] rated impulse withstand voltage
Auxiliary contacts operation
Contacts material
Resistance across terminals
Short-circuit protection
Mechanical durability
Setting
Height
Depth
Width
Product weight
Environment
Standards
CE
EN/IEC 60947-5-1
UL 508
CSA C22.2 No 14
CSA
UL
EAC
TC (standard version)
-25...70 °C
-40...70 °C
Any position
4 gn (f = 30...500 Hz) conforming to IEC 60068-2-6
50 gn conforming to IEC 60068-2-27
Class I conforming to IEC 1140
Class I conforming to IEC 536
Class I conforming to NF C 20-030
IP66 conforming to EN/IEC 60529
Product certifications
Protective treatment
Ambient air temperature for operation
Ambient air temperature for storage
Operating position
Vibration resistance
Shock resistance
Electrical shock protection class
IP degree of protection
Offer Sustainability
RoHS (date code: YYWW)
REACh
Product end of life instructions
Compliant - since 0928 - Schneider Electric declaration of conformi-