X-RAY POWER SUPPLY MODULE
HITEK POWER® XRG70
Exceptionally
small and
reliable
for high-
performance,
compact x-ray
applications
Specifically developed for high-performance, compact
x-ray applications,
the XRG70 series is exceptionally
small and reliable. It offers superior high voltage stability,
stress control, and packaging. This series includes a
variety of models from 25 to 90 kV, and is based on the
grounded filament series of products for grounded cathode
applications. The filament is automatically controlled by the
integral beam current loop-control, and the power stage
utilizes a current-fed resonant push-pull converter to provide
high efficiency while ensuring reliable operation.
Features
› 72 W high voltage output, max
› 20 W grounded filament
› Exceptionally compact
› Local and remote operation
› CE marked for EU LV directive
2006/95/EC
› EU RoHS compliant
to 2002/95/EC
› Safety interlock
› High accuracy and stability
Typical Applications
› X-ray fluorescence (XRF)
› X-ray di raction (XRD)
› X-ray reflectivity (XRR)
› X-ray imaging (XRI)
ASK US ABOUT DERIVATIVES AND SPECIAL
PRODUCTS BUILT TO YOUR REQUIREMENTS.
Note:
Contact AE for custom versions with additional options for power control, interlock, and enable signals.
SPECIFICATION
Output Power
Output Voltage
Output Current
Input Voltage
Ripple
Filament
Filament Disabled
72 W, max, depending on model (constant power available)
Models available from 25 to 90 kV, full spec above 5% output
Models available from 0.8 to 2 mA
24 VDC ±10%, 5.5 A, max (efficiency
≈
75%)
0.05% +10 V peak to peak, max
5.5 VDC, 3.5 A, controlled by internal beam control loop
Filament Disabled: Apply V > 2.8 V on pin 12
Filament enabled: Apply V < 0.8 V on pin 12
Input Impedance: 10 kΩ, max input voltage 24 V
Controls (Analog Version)
Voltage (Remote)
Voltage (Local)
Current (Remote)
Current (Local)
Filament Limit
Filament Standby
Controls (RS-232 Version)
0 to 10 VDC demands 0 to max voltage ±0.25% ±10 V (90 kV version: ±1%)
Internal multi-turn potentiometer for full range setting
0 to 10 VDC demands 0 to max current ±0.25% ±1
µA
Internal multi-turn potentiometer for full range setting
Internal multi-turn potentiometer for full range setting
Internal multi-turn potentiometer for full range setting
Voltage (Remote)
Slew Rate
Current (Remote)
Filament Limit
Filament Standby
Monitors (Analog Version)
12 bit, 0 to FFF demands 0 to max voltage ±0.25% ±10 V (90 kV version: ±1%)
12 bit, 0 to FFF demands 50 msec to 204 sec
12 bit, 0 to FFF demands 0 to max current ±0.25% ±22
µA
12 bit, 0 to FFF demands 0 to 3.5 A, ±2.5%, ±15 mA
12 bit, 0 to FFF demands 0 to 3.5 A, ±2.5%, ±15 mA
Output Voltage
Output Current
Filament Limit
Filament Standby
Filament Current Monitor
Monitors (RS-232 Version)
0 to 10 VDC demands 0 to max voltage ±0.25% ±10 V
0 to 10 VDC demands 0 to max current ±0.25% ±1
µA
Internal multi-turn potentiometer for full range setting
Internal multi-turn potentiometer for full range setting
0 to 10 V for 0 to 3.5 A, accuracy ±2% ±20 mV, output impedance 1 kΩ
Voltage (Remote)
Current (Remote)
Filament Current
Filament Voltage
Voltage Demand
Current Demand
Filament Standby
Filament Limit
Load Regulation
12 bit, 0 to FFF represents 0 to max voltage ±0.45% ±90 V
12 bit, 0 to FFF represents 0 to max current ±0.45% ±2
µA
12 bit, 0 to FFF represents 0 to 3.5 A, ±2.5%, ±15 mA
12 bit, 0 to FFF represents 0 to 10 V ±2.5% ±10 mV
12 bit, 0 to FFF represents 0 to max voltage
12 bit, 0 to FFF represents 0 to max current
12 bit, 0 to FFF represents 0 to 3.5 A
12 bit, 0 to FFF represents 0 to 3.5 A
Output Voltage
Beam Current
Line Regulation
0.01% ±1 V for a 100% change in output current
0.01% ±1
µA
for a 50% voltage change
Output Voltage
Beam Current
Environmental
0.01% for a 10% input voltage change
0.01% for a 10% input voltage change
Storage Temperature
Operating Temperature
Humidity
Altitude
-20 to +85°C (-4 to 185°F)
0 to +45°C (32 to 113°F), max case temperature
80% max relative humidity up to 31°C (88°F), reducing linearly to 50% at 40°C (104°F); non-condensing
2000 m (6500')
SPECIFICATION
Cooling
Stability and Drift
By conduction through the mounting panel (case) and natural convection through the holes in the lid, one side panel,
and the rear panel
Temperature Coefficient
Stability
Protection
100 ppm/ºC, applies to all analog controls and monitors
±0.1% over an eight hour period after 30 min warmup
Input Voltage
HV Output
Filament Output
Safety and Compliance
Reverse polarity and over-current
Continuous short-circuit, intermittent arc, and over-voltage protection
Continuous short-circuit and over-voltage protection
Safety
RoHS
Mechanical
Meets the requirements of the Low Voltage Directive (LVD) 2006/95/EC, by complying with BS EN61010-1 when it is
installed as a component part of other equipment and is CE marked accordingly An M5 earth terminal is provided which
shall be connected to a safety earth at all times when the unit is operational
Meets the requirements of EU Directive 2002/95/EC on the Restriction of use of certain Hazardous Substances in
electrical and electronic equipment (RoHS)
Dimensions
Weight
See outline drawings, on page 6.
Analog models: 3 kg (6.6 lb)
Models with RS-232: 3.2 kg (7 lb)
XRG70-903 (90 kV): 5.43 kg (11.97 lb)
Casing
Input DC Power Connector
HV Output Connector
Filament Output
Connector
Aluminum, clear, non-chrome passivate finish
Twin 63.5 mm (¼") push on spade terminals
HiTek Power®-designed detachable connector
Molex 2W minifit 39-29-1028
CONNECTIONS
Pin
Name
MONITOR RETURN
KV MON
mA MON
INTERLOCK SIGNAL
In/Out
Output
Output
Output
Output
Function
Zero volt for commands and monitors
To read the actual voltage
To read the actual beam current
Relay contact ground/open
Ground = interlock open
Open = interlock closed
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
+10 V REF
FIL CURRENT MON
KV PROG
LOCAL KV PROG
FIL I LIMIT
mA PROG
LOCAL mA PROG
FIL ENABLE
HV ENABLE
FIL I STANDBY
INTERLOCK RETURN
Output
Output
Input
Output
Output
Input
Output
Input
Input
Output
Input
To be used as a reference voltage
To read the actual filament current
To set the output voltage
To be connected to pin 7 in local mode, adjust potentiometer and read demand
Read and adjust the filament current limit demand via potentiometer.
To set the output current
To be connected to pin 10 in local mode, adjust potentiometer and read demand
Active low
Active low
Read and adjust the filament standby demand via potentiometer.
To be connected to front panel stud and not monitor return