EEWORLDEEWORLDEEWORLD

Part Number

Search

RP240H-11015SRW/P

Description
Isolated DC/DC converter 240W 43-160Vin 15Vout 16A
CategoryPower/power management    The power supply circuit   
File Size4MB,16 Pages
ManufacturerRECOM
Environmental Compliance
Download Datasheet Parametric View All

RP240H-11015SRW/P Overview

Isolated DC/DC converter 240W 43-160Vin 15Vout 16A

RP240H-11015SRW/P Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerRECOM
package instructionPACKAGE-9
Reach Compliance Codecompliant
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage160 V
Minimum input voltage43 V
Nominal input voltage110 V
JESD-30 codeR-PDMA-P9
length61 mm
Number of functions1
Output times1
Number of terminals9
Maximum output voltage16.5 V
Minimum output voltage12 V
Nominal output voltage15 V
Package body materialPLASTIC/EPOXY
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Maximum seat height13.2 mm
surface mountNO
technologyHYBRID
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output240 W
Fine-tuning/adjustable outputYES
width57.9 mm
Features
Regulated
Converter
Description
• 4:1 wide input range
• 3kVAC reinforced insulation for 110Vin
2.25kVDC basic insulation for 24Vin & 48Vin
• Efficiency up to 91%
• No minimum load required
• UL60950-1, EN50155 & IEC/EN60950-1 certified
DC/DC Converter
RP240H-RW
240 Watt
Half Brick
Single Output
The half-brick RP240H series DC/DC converters are designed for railway rolling stock and high voltage battery
applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to
160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal base-
plates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink).
The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock
and vibration environments. The converters are EN50155, UL60950 and IEC/EN60950 certified. The RP240H-RW
series have a three year warranty.
Selection Guide
Input
Output
Voltage Range Voltage
[VDC]
[VDC]
RP240H-2405SRW
9-36
5
RP240H-2412SRW
9-36
12
RP240H-2415SRW
9-36
15
RP240H-2424SRW
9-36
24
RP240H-2448SRW
9-36
48
RP240H-4805SRW
16.5-75
5
RP240H-4812SRW
16.5-75
12
RP240H-4815SRW
16.5-75
15
RP240H-4824SRW
16.5-75
24
RP240H-4848SRW
16.5-75
48
RP240H-11005SRW 43-160
5
RP240H-11012SRW 43-160
12
RP240H-11015SRW 43-160
15
RP240H-11024SRW 43-160
24
RP240H-11048SRW 43-160
48
Notes:
Note1:
Part Number
Output
Current
[mA]
36000
15000
12000
7500
3700
40000
18000
14000
9000
4500
44000
20000
16000
10000
5000
Input
(1)
Current
[mA]
8333
8427
8333
8333
8314
4578
5000
4807
5000
5000
2247
2451
2424
2451
2451
Output
Power
[W]
180
180
180
180
177.5
200
216
210
216
216
220
240
240
240
240
Efficiency
(1)
Max. Capacitive
typ.
Load
[%]
[µF]
90
72000
89
12500
90
8000
90
3100
89
770
91
80000
90
15000
91
9000
90
3700
90
930
89
88000
89
16600
90
10600
89
4100
89
1000
E196683
EN50155 certified
IEC/EN60950-1 certified
UL60950-1 certified
Efficiency is tested by nominal Vin, full load and at 25°C
Model Numbering
RP240H-__ __SRW/_ _
Input Voltage
Output Voltage
Single
Ordering Examples
RP240H-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function
RP240H-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RP240H-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function with premounted Heat-sink
Notes:
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
Note3: add suffix “-HC” for premounted Heat-sink
(compatible with all other suffixes)
www.recom-power.com
REV.: 3/2018
Package
(3)
CTRL Logic
(2)
https://www.recom-power.com/pdf/
Powerline_DC-DC/RSPxxx-168.pdf
PB-1
Characteristic impedance of RF lines
The formula is as shown in the figure:...
dontium RF/Wirelessly
What is the difference between static electricity and leakage?
I would like to know in detail, what is the difference between static electricity and leakage?...
yimeng1988 Industrial Control Electronics
I just started, I don't know what to learn, I need information to get started
I just started to use Zigbee and I don't know how to get started. Is there any information suitable for beginners? Thank you very much...
mxb1314 RF/Wirelessly
HMI chip solutions are coming soon
The purpose of this post is to ask you to recommend some chips that can be used to make HMI solutions. The following is an introduction to some chips I know. 1. Allwinner F1C100S 1. Instruction set co...
bigbat Domestic Chip Exchange
When a COM port is occupied by a virtual serial port of another device, can the name of the COM port be changed?
A device occupies multiple virtual serial ports (such as COM4--COM9), which conflict with the original serial port number. Can the original serial port be changed to another name? For example, COM4 to...
cgl123456 Embedded System
C6713 fft time spent
Experts: I am doing fft testing recently and have a few questions: (1). I use a counter to test the running cycles of the function DSPF_sp_fftSPxSP. Looking at the examples on the Internet, before tes...
游侠339 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2648  568  89  915  106  54  12  2  19  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号