EEWORLDEEWORLDEEWORLD

Part Number

Search

77C-LR-KW/HP

Description
Industrial relay 95-125V CROSS-WIRED ALT. RELAY W/ SW
CategoryMechanical and electronic products    relay    Industrial relay   
File Size490KB,3 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Environmental Compliance
Download Datasheet Parametric Compare View All

77C-LR-KW/HP Overview

Industrial relay 95-125V CROSS-WIRED ALT. RELAY W/ SW

77C-LR-KW/HP Parametric

Parameter NameAttribute value
MakerLittelfuse
Product CategoryIndustrial relay
Shipping restrictionsMouser does not currently sell this product.
typeSingle-Phase Current and Voltage Monitor
Contact current rating10 A
switching voltage100 VAC to 240 VAC
Installation stylePanel
Installation typeDIN Rail
series77C-KW/HP
length129.54 mm
width99.06 mm
high78.74 mm
EncapsulationBulk
Contact formSPDT (1 Form C)
Power consumption5 W
productProtection Relays
Factory packaging quantity1
unit weight544.310 g
Protection Relays
Motor and Pump Protection - Single-Phase Pump Protection
77C-KW/HP SERIES
Single-Phase Current & Voltage Monitor
Description
The 77C-KW/HP and 77C-LR-KW/HP are fully programmable
pump protection relays which will monitor the voltage and
current for high or low voltage, overload and underload
conditions based on power, in one package. The underpower trip
feature is desirable anytime the current vs.load characteristic is
non-linear or has little change. In general terms, smaller motors
and slow-speed motors have little change in current over the
normal load range. Larger motors that are running light loads will
also show small current changes over the operating load range.
Common uses include pumping applications where motors run
slower than around 3400 rpm and usually have small current vs
load changes; such as slow speed mixer or agitator motors up to
50 hp, and magdrive or can pumps.
Power is Linear, equal
sensitivity at both
low and high
loads.
Current is not linear, low
sensitivity for low loads
and high sensitivity
for high loads.
Wiring Diagram
TYPICAL WIRING DIAGRAM FOR MODEL 77C-KW/HP
WITH MOTOR CONTROL
L1
L2
COIL
CONTACTOR
No Load
Full Load
Current
No Load
Power
Full Load
CONTROL
POWER
240 VAC
OR LESS
The Littelfuse PumpSaver relay provides the high sensivity of a
power monitor to protect pump motors from dry run and dead
head conditions.
A
B
C
NOTE:
PHASES A & C
ARE INACTIVE.
Features & Benefits
FEATURES
BENEFITS
Increases reliability for non-linear motors where the
load characteristic has little change
Visual indication for programming, viewing real-time
voltage, current, kilowatts or horsepower, and last
fault code
Allows user flexibility to fine-tune the relay for
maximum protection in any application.
Provides instant troubleshooting diagnostics
Increases safety through remote display of run-hour
meter, last four fault codes, without the need to open
the cabinet. Aids with arc flash safety regulations.
Reset options: automatic, manual using pushbutton
on relay, or remotely with optional 777-MRSW
remote reset kit.
Compatible with Modbus using optional
communications module (RS485MS-2W)
Underload protection
Built-in display
15 programmable
criteria settings
START
M
STOP HAND
OFF
PILOT AUTO
TO MOTOR
TYPICAL WIRING DIAGRAM FOR MODEL 77C-KW/HP WITH EXTERNAL CT
A
LITTELFUSE RECOMMENDS USING CTs THAT HAVE TERMINALS TO AID
B
CONVENIENCE WHEN INSTALLING CTs.
Last fault memory
Remote display
compatibility
Flexible reset
10 - 12 AWG
STRANDED WIRE
A
120-240VAC 1Ø
50/60 HZ
B
PILOT DUTY RATING
480VA AT 240VAC
C
Network
communications
capability
Ordering Information
MODEL
LINE
VOLTAGE
MOTOR FULL
AMP RANGE
DESCRIPTION
MOTOR
NOTE:
PHASES A & C ARE INACTIVE. USE PHASE B FOR ALL ACTIVE
CURRENT MEASUREMENTS. CT SECONDARY MUST MAKE FIVE
PASSES THROUGH THE PHASE B CONDUCTOR WINDOW.
NOTE:
OTHER NECESSARY CONNECTIONS ARE NOT SHOWN
77C-KW/HP
2-90A (external CTs
100-240VAC
required above 90A)
1-9A (external CTs
required above 9A)
Provides 480VA @
240VAC output SPDT
(Form C) relay contacts
Provides 480VA @
240VAC output SPDT
(Form C) relay contacts
Rev: 1-A-062816
77C-LR-KW/HP 100-240VAC
© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/77ckwhp
www.littelfuse.com/

77C-LR-KW/HP Related Products

77C-LR-KW/HP 77C-KW/HP
Description Industrial relay 95-125V CROSS-WIRED ALT. RELAY W/ SW Industrial relay 95-125V 8-PIN ALTERNATING RELAY
Maker Littelfuse Littelfuse
Product Category Industrial relay Industrial relay
Shipping restrictions Mouser does not currently sell this product. Mouser does not currently sell this product.
type Single-Phase Current and Voltage Monitor Single-Phase Current and Voltage Monitor
Contact current rating 10 A 10 A
switching voltage 100 VAC to 240 VAC 100 VAC to 240 VAC
Installation style Panel Panel
Installation type DIN Rail DIN Rail
series 77C-KW/HP 77C-KW/HP
length 129.54 mm 129.54 mm
width 99.06 mm 99.06 mm
high 78.74 mm 78.74 mm
Encapsulation Bulk Bulk
Contact form SPDT (1 Form C) SPDT (1 Form C)
Power consumption 5 W 5 W
product Protection Relays Protection Relays
Factory packaging quantity 1 1
unit weight 544.310 g 544.310 g

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2016  1118  274  1997  1358  41  23  6  28  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号