G6K-2P-RF DC24

Description
Low Signal Relay, HF
CategoryMechanical and electronic products    relay    High frequency/radio frequency relay   
File Size2MB,9 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

G6K-2P-RF DC24 Overview

Low Signal Relay, HF

G6K-2P-RF DC24 Parametric

Parameter NameAttribute value
MakerOMRON
Product CategoryHF/RF relay
coil voltage24 VDC
Contact current rating1 A
frequency1 GHz
Contact terminationSolder Terminal
Maximum switching current1 A
Coil typeNon-Latching
Power consumption100 mW
insulation30 dB
Insertion loss0.2 dB
seriesG6K-2P-RF
EncapsulationTube
Contact formDPDT (2 Form C)
Contact rating300 mA at 125 VAC, 1 A at 30 VDCA
coil current4.6 mA
Coil resistance5.22 kOhms
VSWR1.2
Factory packaging quantity300
unit weight700 mg
G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
Surface-mounting, 1-GHz-Band/
3-GHz-Band, Miniature, DPDT,
High-frequency Relay
• Superior high-frequency characteristics (at 1 GHz), such as an isolation
of 20 dB min. between contacts of the same polarity of 30 dB min. be-
tween contacts of different polarity with an insertion loss of 0.2 dB max.
• Miniaturized to 10.3
×
6.9
×
5.4 mm (L
×
W
×
H).
• Rated power consumption of 100 mW with high sensitivity
• Single-side stable and single-winding latching models are available.
• Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space.
• G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint.
• New PCB terminals models are available.
RoHS Compliant
■Model
Number Legend
G 6 K@ -@
@
-@ -@
— —— — —
1
2 3
4
5
1. Relay Function
None: Single-side stable
U: Single-winding latching
2. Number of poles/
Contact Form
2: 2-pole/ DPDT (2c)
3. Terminal Shape
F: Outside-L surface mount-
ing terminals
P: PCB terminals
4. Special Function
RF: High-frequency compatible
5. Terminal Shape
None: Standard
S: Small footprint
T: Compatible with 3 GHz
■Application
Examples
• Communications equipment
• Broadcasting and audio-visual equipment
• Test & measurement equipment
G
6
K
U
2
F
P
( )-
( )-
R
F
S
,
(-
-
T
)
■Ordering
Information
●Standard
Models with Surface-mounting Terminals
Standard Specifications
Relay Function
Single-side stable
Single-winding latching
Enclosure rating
Fully sealed
Contact form
DPDT
(2c)
Model
G6K-2F-RF
G6KU-2F-RF
Rated coil voltage
3, 4.5, 5, 12, 24 VDC
3, 4.5, 5, 12, 24 VDC
Minimum packing unit
300 pcs/tray
300 pcs/reel
Board space-saving model
Relay Function
Single-side stable
Single-winding latching
Enclosure rating
Fully sealed
Contact form
DPDT
(2c)
Model
G6K-2F-RF-S
G6KU-2F-RF-S
Rated coil voltage
3, 4.5, 5, 12, 24 VDC
3, 4.5, 5, 12, 24 VDC
Minimum packing unit
300 pcs/tray
300 pcs/reel
Compatible with 3 GHz
Relay Function
Single-side stable
Single-winding latching
Enclosure rating
Fully sealed
Contact form
DPDT
(2c)
Model
G6K-2F-RF-T
G6KU-2F-RF-T
Rated coil voltage
3, 4.5, 5, 12, 24 VDC
3, 4.5, 5, 12, 24 VDC
Minimum packing unit
300 pcs/tray
300 pcs/reel
PCB terminals
Relay Function
Single-side stable
Enclosure rating
Fully sealed
Contact form
DPDT (2c)
Model
G6K-2P-RF
Rated coil voltage
3, 4.5, 5, 12, 24 VDC
Minimum packing unit
30 pcs/tube
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G6K-2F-RF DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.
Note 2. When ordering Relays in tape packing, add "-TR03" to the end of the model number.
Example: G6K-2F-RF-TR03 DC3
Relays per reel: 300 pcs for -TR03
Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case.
When ordering tape packing, minimum order unit is 1 reel (300 pcs
1 = 300 pcs).
Note 3. Surface mounting terminal (SMT) standard models are shipped in moisture-proof package.
PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package.
1
Have you ever used 51 interrupt level trigger?
A few days ago, I wanted to use external interrupts, using level triggering (this can add button debounce, but edge triggering doesn't work), but when I debugged the program, I found that the external...
竹林中人 51mcu
I am a little confused: are you charging people for electricity by connecting the meter privately?
For example, the commercial housing sold in the community was not equipped with an electricity meter. Later, they had to pay for the installation of the electricity meter. I paid the electrician more ...
wangfuchong Talking
Software and driver connection
Now I have a very difficult problem (for me). I originally had a USB hardware (industrial camera) and its driver, and a software (VC++ image processing) that can be developed to connect and use with t...
zhoulm Embedded System
Look at the TI IOT structure diagram and talk about your understanding of the Internet of Things!
Node, gateway & cloud. [b]Nodes,[/b] devices used to collect information or control things, typically include processors, sensors, connectivity, power management and some analog signal chain. The sele...
soso RF/Wirelessly
How to configure the IC card interface chip NCN6001
Now configure the power-on sequence of the NCN6001 chip as follows: WrSPICmdOne(0xa5); WrSPICmdOne(0x83); DelayMS(1); WrSPICmdOne(0x87); DelayMS(6); WrSPICmdOne(0x97); After this configuration, the IC...
sb576763418 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1392  373  772  628  2839  29  8  16  13  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号