EEWORLDEEWORLDEEWORLD

Part Number

Search

LP-CC-2-1/4

Description
Industrial & Electrical Fuse 600V 2.25A Time Delay Low Peak
CategoryCircuit protection    The fuse    Industrial and electrical fuse   
File Size420KB,4 Pages
ManufacturerBussmann (Eaton)
Download Datasheet Parametric View All

LP-CC-2-1/4 Overview

Industrial & Electrical Fuse 600V 2.25A Time Delay Low Peak

LP-CC-2-1/4 Parametric

Parameter NameAttribute value
MakerBussmann (Eaton)
Product CategoryIndustrial and electrical fuses
Shipping restrictionsMouser does not currently sell this product.
RoHSN
seriesLP-CC
productClass CC Fuse
Current rating2.25 A
Voltage ratingAC600 VAC
Fuse typeTime Delay / Slow Blow
Voltage ratingDC300 VDC
interrupt rating200 kA
Subject typeCartridge Fuses
Installation styleHolder
Termination typeClip
Fuse size/groupLow-Peak
Indicator typeWithout Indicator
EncapsulationBulk
diameter0.41 in
length1.5 in
typeGeneral
Factory packaging quantity10
unit weight8.618 g
Technical Data 1023
Effective October 2017
Supersedes February 2016
Low-Peak™ LP-CC Class CC 600 Vac/300 Vdc,
1/2-30 A time-delay fuses
Catalog numbers (amps)
LP-CC-1/2
LP-CC-6/10
LP-CC-8/10
LP-CC-1
LP-CC-1-1/8
LP-CC-1-1/4
LP-CC-1-4/10
LP-CC-1-1/2
LP-CC-1-6/10
LP-CC-1-8/10
LP-CC-2
LP-CC-2-1/4
LP-CC-2-1/2
LP-CC-2-8/10
LP-CC-3
LP-CC-3-2/10
LP-CC-3-1/2
LP-CC-4
LP-CC-4-1/2
LP-CC-5
LP-CC-5-6/10
LP-CC-6
LP-CC-6-1/4
LP-CC-7
LP-CC-7-1/2
LP-CC-8
LP-CC-9
LP-CC-10
LP-CC-12
LP-CC-15
LP-CC-20
LP-CC-25
LP-CC-30
Carton quantity:
Amp rating
1/2-30
Carton qty.
10
Catalog symbol:
Dimensions - in (mm)
1.5 (38)
0.41 (10)
LP-CC-(amp)
Description:
Bussmann™ series Ultimate protection Low-Peak
Class CC current-limiting, time-delay fuses. Time-
delay – 12 seconds (minimum) at 200% of rated
current.
Features:
Specifications:
Ratings
200kA interrupting rating complies with NEC
®
Section 110.9 for today’s large capacity systems.
Fast short-circuit protection and dual-element,
time-delay performance provide ultimate
protection.
Reduces existing fuse inventory by up to 33%
when upgrading to Low-Peak fuses.
Consistent 2:1 amp rating ratios for all Low-
Peak fuses make selective coordination easy.
Time-delay characteristic avoids unwanted
fuse openings from surge currents while fast
response speed under fault conditions provides
a high degree of current limitation.
Current-limitation protects downstream
components against damaging thermal and
magnetic effects of fault currents.
A superior, all-purpose, space-saving branch
circuit fuse that meets most protection
requirements up to 30 A.
Very compact physical size that’s only 13/32” x
1-1/2” (10 x 38mm) with rejction tip.
Proper sizing can provide “No Damage” Type 2
coordinated protection for NEMA and IEC motor
controllers.
Can be used where either a time-delay or a
fast-acting fuse is needed, making selection
easier and reducing spare fuse inventories for
substantial cost reduction.
Superior protection for small horsepower motor
circuits.
Volts
600 Vac
300 Vdc (1/2 to 2-8/10 A, 20-30 A)
150 Vdc (3-15 A)
Amps 1/2-30 A
IR
200 kA Vac RMS Sym.
20 kA Vdc
Agency information
UL
®
Listed Class CC, Std. 248-4,
Guide JDDZ, File E4273
CSA
®
Certified; Class 1422-02, File 53787
CE
RoHS compliant (20-30A)
Briefly talk about typedef struct
[i=s]This post was last edited by freebsder on 2018-12-4 00:45[/i] The problem comes from typedef struct Node { ElemType data; struct Node *next; }Node;. Changing it to typedef struct { ElemType data;...
freebsder MCU
How a Hardware Engineer Becomes a Project Manager
The project manager controls the entire process of the product from project establishment, development to market, to technical support, etc. In order to become a project manager, hardware engineers mu...
new_sun Talking about work
Plan to acquire a security company
[align=left][font=宋体][size=10.5pt]The company intends to acquire a security company. The acquired company must at least meet the following conditions: [/size][/font][/align][align=left][font=宋体][size=...
yongmei Talking about work
How to implement hard shutdown protection in XP EMBEDDED? It doesn't matter if the data is not saved when shutting down, as long as the operating system is not damaged.
I am working on a project related to XP EMBEDDED recently. The project requires the ability to implement a hard shutdown, which is to unplug the power directly, and is different from the shutdown butt...
hamsun2008 Embedded System
Designing a compact, efficient and high-performance multi-parameter patient monitor
Continuously measuring patient vital signs such as heart rate, respiratory rate and blood oxygen saturation (SpO2) is critical to providing effective care, and the ability to measure these signs simul...
EEWORLD社区 TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1772  1213  703  2687  996  36  25  15  55  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号