EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-PCW22-MYY

Description
Isolated DC/DC converter VI-PCW22-MYY
CategoryThe power supply    DC/DC converters    Isolated DC/DC converter   
File Size726KB,9 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-PCW22-MYY Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-PCW22-MYY - - View Buy Now

VI-PCW22-MYY Overview

Isolated DC/DC converter VI-PCW22-MYY

VI-PCW22-MYY Parametric

Parameter NameAttribute value
MakerVICOR
Product CategoryIsolated DC/DC converter
Number of outputs2 Output
Input voltage18 VDC to 36 VDC
Output voltage—channel 115 VDC
Output voltage—channel 215 VDC
Insulation voltage4242 V
Installation styleChassis Mount
length218.4 mm
width124.5 mm
high25.2 mm
industryIndustrial, Commercial
productIsolated
seriesComPAC
applicationIndustrial, Telecommunication
size218.4 mm x 124.5 mm x 25.2 mm
Maximum operating temperature+ 85 C
Minimum operating temperature- 55 C
ComPAC™
DC-DC Switchers
50 – 600 Watts; 1 – 3 Outputs
Features & Benefits
RoHS Compliant (VE versions)
Inputs 24, 48 and 300V
DC
Any output: 1 – 95V
DC
Meets EN55022 Class A
conducted emissions (See Notes)
cULus, cTÜVus (60950-1)
CE marked (LVD)
80 – 90% efficiency
Up to 10W/in
3
Master disable
Overvoltage shutdown
Configuration Chart
Configuration
[a]
Single Output
VI‑LC
VI‑MC
VI‑NC
A
FF A
F A
Output Power
Number of
Modules
Dimensions
F
F
A
A
50 – 200W
100 – 400W
300 – 600W
1
2
3
Dual Output
VI‑PC
VI‑QC
A
FF A
F A
A
FF A
F A
F A
8.6 x 2.5 x 0.99in
[218,4 x 63,5 x 25,2mm]
8.6 x 4.9 x 0.99in
[218,4 x 124,5 x 25,2mm]
8.6 x 7.3 x 0.99in
[218,4 x 185,4 x 25,2mm]
8.6 x 4.9 x 0.99in
[218,4 x 124,5 x 25,2mm]
8.6 x 7.3 x 0.99in
[218,4 x 185,4 x 25,2mm]
8.6 x 7.3 x 0.99in
[218,4 x 185,4 x 25,2mm]
F
A
F F A
A F
A
100 – 400W
150 – 600W
2
3
A
FF F A A
F A
A
FF F A A
F A
Triple Output
VI‑RC
[a]
150 – 600W
3
Product Description
ComPAC delivers up to 600W from
one, two, or three outputs in a package
just 0.99in [25,2mm] in height with the
field‑proven performance, high efficiency
and high reliability inherent in Vicor
component‑level power converters.
ComPAC meets conducted emissions of
EN55022 Class A. ComPAC is offered with
input voltage ranges optimized for industrial
and telecommunication applications and
provides extended input over voltage
capability, undervoltage lockout and
master disable.
A A
F F F A
Substitute VE– for VI– for RoHS‑compliant versions
A F A
A
FF F F A
Input
A
Voltage
Output Voltage
Z
= 2V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
F
Nominal
1
= 24V
W
= 24V
3
= 48V
N
= 48V
6
= 300V
A
Input
Low Line
Maximum
Transient
Range Full
75% Max.
[b]
Power
(1s)
Power
Power
21 – 32V
18 – 36V
42 – 60V
36 – 76V
200 – 400V
5V
Outputs
150W
200W
(1)
(1)
(2)
(2)
(2)
18
N/A
41
N/A
188
>5V
Outputs
150W
200W
36
N/A
72
N/A
425
<5V
Outputs
30A
40A
F
A
Y
= 3.3V
0
= 5V
X
= 5.2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
M
= 10V
1
= 12V
P
= 13.8V
[b]
Max
Output
per Module
(1)
(2)
Packaging Options
Conduction Cooled Models Available.
Add “‑CC” to the end of the part number.
F A
(Consult factory for details.)
Extended heat sink available.
Add “–H1” to end of part number.
Product Grade Case Temps. ºC
Grade
E
=
C
=
I
=
M
=
Operating
–10 to +85
–25 to +85
–40 to +85
–55 to +85
Storage
–20 to +100
–40 to +100
–55 to +100
–65 to +100
Output Power / Current
OUT
F
V
A
5V
V
OUT
< 5V
Y
= 10A
X
= 15A
W
= 20A
V
= 30A
U
= 40A
Y
= 50W
X
= 75W
W
= 100W
V
= 150W
U
= 200W
Output Power / Current
F
A
V
OUT
5V
V
= 150W
U
= 200W
S
= 300W
Q
= 400W
V
OUT
< 5V
W
= 20A
V
= 30A
U
= 40A
S
= 60A
Q
= 80A
W
= 100W
Output Power / Current
F
A
V
OUT
5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
ComPAC™ DC-DC
Page 1 of 8
Rev 1.3
10/2014
Question: Question about 6410 serial port application?
I wrote a serial port application using VS2005. After writing it, I synchronized it to the 6410 board, but when I clicked to open the serial port, it failed. Could you please help me see how to write ...
zjuxuliyan Embedded System
Summary of uboot transplantation related information and original code modification files
After a few days of summarizing, I finally summarized the relevant information. If anyone wants the original code, please contact me. If it is not well written, please point it out![[i] This post was ...
daicheng Embedded System
Summary of the problem of STM32 interruption
1. Problem: If you do not operate properly, the STM32 interrupt will enter twice each time.2. Verification method: For example, the 1ms interrupt program below:void TIM6_IRQHandler(void) //1ms{ms_100_...
jasonb stm32/stm8
Infrared touch screen
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:00[/i][size=15pt] [/size][size=15pt][img]1[/img][img]1[/img][img]1[/img][img]1[/img][img]1[/img] [/size][b][size=22pt] [/size][/b][b][f...
红外线触摸屏 Mobile and portable
Super detailed teaching you how to use HFSS to design and simulate inverted F antenna 1
Inverted F Antenna Introduction The inverted-F antenna (IFA) is a deformation structure of the monopole antenna, which has the advantages of small size, simple structure, easy matching and low manufac...
btty038 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 164  2564  1623  2472  1755  4  52  33  50  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号