and the UR logo are registered trademarks of UL LLC. Other trademarks, product, and company names are the property of their respective owners and do not imply specific product and/or vendor
endorsement, sponsorship or association.
2
XLamp
®
XHp35.2 LED
FLuX CHArACtEristiCs, EAsyWHitE
®
orDEr CoDEs AnD bins (t
J
= 85 °C)
The following table provides order codes for XLamp XHP35.2 LEDs. For a complete description of how the flux and chromaticity groups
are reflected in the bin code and order code nomenclature, please see the Bin and Order Code Formats section (page 21).
Minimum
Luminous Flux
@350 mA
typ
Group
e2
D4
D4
D2
C4
90
C2
B4
70
e2
D4
D4
D2
C4
90
C2
B4
70
e2
D4
D4
D2
C4
90
C2
B4
e2
70
D4
D2
4000 K
80
D4
D2
C2
B4
Flux (lm)
@ 85 °C
590
550
550
510
475
440
410
590
550
550
510
475
440
410
590
550
550
510
475
440
410
590
550
510
550
510
440
410
40e
40e
45e
45e
50e
57e
57e
Group
nominal
CCt
Min
70
Cri
3-step
order Code
Group
57e
5-step
order Code
XHP35B-00-0000-0D0Be257e
XHP35B-00-0000-0D0BD457e
XHP35B-00-0000-0D0HD457e
XHP35B-00-0000-0D0HD257e
XHP35B-00-0000-0D0UC457e
XHP35B-00-0000-0D0UC257e
XHP35B-00-0000-0D0UB457e
XHP35B-00-0000-0D0Be250e
XHP35B-00-0000-0D0BD450e
XHP35B-00-0000-0D0HD450e
XHP35B-00-0000-0D0HD250e
XHP35B-00-0000-0D0UC450e
XHP35B-00-0000-0D0UC250e
XHP35B-00-0000-0D0UB450e
XHP35B-00-0000-0D0Be245e
XHP35B-00-0000-0D0BD445e
XHP35B-00-0000-0D0HD445e
XHP35B-00-0000-0D0HD245e
XHP35B-00-0000-0D0UC445e
XHP35B-00-0000-0D0UC245e
XHP35B-00-0000-0D0UB445e
XHP35B-00-0000-0D0Be240e
XHP35B-00-0000-0D0BD440e
XHP35B-00-0000-0D0BD240e
XHP35B-00-0000-0D0HD440e
XHP35B-00-0000-0D0HD240e
XHP35B-00-0000-0D0UC240e
XHP35B-00-0000-0D0UB440e
5700 K
80
57e
5000 K
80
50e
4500 K
80
45e
90
40e
Notes:
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and ±2 on CRI measurements.
See the Measurements section (page 23).
•
Cree XLamp XHP35.2 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
and the UR logo are registered trademarks of UL LLC. Other trademarks, product, and company names are the property of their respective owners and do not imply specific product and/or vendor
endorsement, sponsorship or association.
3
XLamp
®
XHp35.2 LED
FLuX CHArACtEristiCs, EAsyWHitE
®
orDEr CoDEs AnD bins (t
J
= 85 °C) - Continued
nominal
CCt
Min
Cri
typ
Minimum
Luminous Flux
@350 mA
Group
e2
70
D4
D2
3500 K
D4
80
D2
C4
90
C2
B4
D4
D2
D2
C4
C2
90
B4
B2
80
2700 K
90
C4
C2
B4
B2
Flux (lm)
@ 85 °C
590
550
510
550
510
475
440
410
550
510
510
475
440
410
380
475
440
410
380
27G
XHP35B-00-0000-0D0UB427G
XHP35B-00-0000-0D0UB227G
30G
XHP35B-00-0000-0D0UC230G
XHP35B-00-0000-0D0UB430G
XHP35B-00-0000-0D0UB230G
27e
30e
35G
XHP35B-00-0000-0D0UC235G
XHP35B-00-0000-0D0UB435G
35e
35e
35e
Group
3-step
order Code
Group
5-step
order Code
XHP35B-00-0000-0D0Be235e
XHP35B-00-0000-0D0BD435e
XHP35B-00-0000-0D0BD235e
XHP35B-00-0000-0D0HD435e
XHP35B-00-0000-0D0HD235e
XHP35B-00-0000-0D0HC435e
XHP35B-00-0000-0D0UC235e
XHP35B-00-0000-0D0UB435e
XHP35B-00-0000-0D0BD430e
XHP35B-00-0000-0D0BD230e
XHP35B-00-0000-0D0HD230e
XHP35B-00-0000-0D0HC430e
XHP35B-00-0000-0D0UC230e
XHP35B-00-0000-0D0UB430e
XHP35B-00-0000-0D0UB230e
XHP35B-00-0000-0D0HC427e
XHP35B-00-0000-0D0HC227e
XHP35B-00-0000-0D0UB427e
XHP35B-00-0000-0D0UB227e
70
30e
3000 K
80
30e
27e
Notes:
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and ±2 on CRI measurements.
See the Measurements section (page 23).
•
Cree XLamp XHP35.2 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
and the UR logo are registered trademarks of UL LLC. Other trademarks, product, and company names are the property of their respective owners and do not imply specific product and/or vendor
endorsement, sponsorship or association.
4
XLamp
®
XHp35.2 LED
FLuX CHArACtEristiCs, Ansi WHitE orDEr CoDEs AnD bins (t
J
= 85 °C)
The following table provides order codes for XLamp XHP35.2 LEDs. For a complete description of how the flux and chromaticity groups
are reflected in the bin code and order code nomenclature, please see the Bin and Order Code Formats section (page 21).
Minimum
Luminous Flux
@ 350 mA
typ
68
Group
e2
D4
e2
D4
D4
D2
C4
90
C2
B4
0
70
6500 K
1A, 1B, 1C, 1D
80
68
e2
D4
e2
D4
D4
D2
C4
90
C2
B4
0
70
80
68
e2
D4
e2
D4
D4
D2
C4
90
C2
B4
Flux (lm)
@ 85 °C
590
550
590
550
550
510
475
440
410
590
550
590
550
550
510
475
440
410
590
550
590
550
550
510
475
440
410
XHP35B-00-0000-0D00e20DT
XHP35B-00-0000-0D00D40DT
XHP35B-00-0000-0D0Be20DT
XHP35B-00-0000-0D0BD40DT
XHP35B-00-0000-0D0HD40DT
XHP35B-00-0000-0D0HD20DT
XHP35B-00-0000-0D0UC40DT
XHP35B-00-0000-0D0UC20DT
XHP35B-00-0000-0D0UB40DT
XHP35B-00-0000-0D00e20e1
XHP35B-00-0000-0D00D40e1
XHP35B-00-0000-0D0Be20e1
XHP35B-00-0000-0D0BD40e1
XHP35B-00-0000-0D0HD40e1
XHP35B-00-0000-0D0HD20e1
XHP35B-00-0000-0D0UC40e1
XHP35B-00-0000-0D0UC20e1
XHP35B-00-0000-0D0UB40e1
XHP35B-00-0000-0D00e20Dv
XHP35B-00-0000-0D00D40Dv
XHP35B-00-0000-0D0Be20Dv
XHP35B-00-0000-0D0BD40Dv
XHP35B-00-0000-0D0HD40Dv
XHP35B-00-0000-0D0HD20Dv
XHP35B-00-0000-0D0UC40Dv
XHP35B-00-0000-0D0UC20Dv
XHP35B-00-0000-0D0UB40Dv
nomimal
CCt
Cri
Chromaticity regions
Min
0
70
80
order Code
7000 K
0A, 0B, 0C, 0D,
0R, 0S, 0T, 0U,
1A, 1B, 1C, 1D,
1R, 1S, 1T, 1U
6000 K
1A, 1B, 1C, 1D,
1R, 1S, 1T, 1U,
2A, 2B, 2C, 2D,
2R, 2S, 2T, 2U
Notes:
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and ±2 on CRI measurements.
See the Measurements section (page 23).
•
Cree XLamp XHP35.2 LED order codes specify only a minimum flux bin and not a maximum. Cree may ship reels in flux bins higher than the minimum
specified by the order code without advance notice. Shipments will always adhere to the chromaticity bin restrictions specified by the order code.
and the UR logo are registered trademarks of UL LLC. Other trademarks, product, and company names are the property of their respective owners and do not imply specific product and/or vendor
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
System design is a complex process. It is not enough to just use ICs. There are many details to consider. This article uses a high-fidelity music playback system as an example to introduce how to s...[Details]
I. Introduction
In the field of power conversion, isolated converters (forward, flyback, and double-ended) with low output DC voltage all use MOSFET as the rectifier device. Since these devi...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
MediaTek (2454) announced the acquisition of F-MStar (3697) and attracted the attention of IC design industry. This morning, Gartner Semiconductor Industry Research Director Hong Cenwei analyzed ...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
Introduction
X1226 has the functions of clock and calendar. The clock relies on hour, minute and second registers to track, and the calendar relies on date, week, month and year registers to tr...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
In the "digital pressure measurement" experimental device of applied physics, the subject technical knowledge of analog circuits, digital circuits, sensors and single-chip microcomputers is used. In o...[Details]
Fruit planting is an important part of China's agricultural development, and fruit tree pest control operations are becoming more and more important. At present, the overall level of pesticide applica...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]
People who often surf the Internet until late at night, their families always complain that turning on the big lights in the living room affects their rest, but some people don't have keyboard ligh...[Details]
In order to develop lighting LED technology, developed countries attach great importance to the research of LED testing methods and standards. For example, the National Institute of Standards and T...[Details]
Current
measurement:
Magnetic balance Hall current
sensor
is used
. The sensor can measure AC from DC to 100kHz.