EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-R2111-CWWW

Description
Isolated DC/DC converter VI-R2111-CWWW
CategoryThe power supply    DC/DC converters    Isolated DC/DC converter   
File Size719KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-R2111-CWWW Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-R2111-CWWW - - View Buy Now

VI-R2111-CWWW Overview

Isolated DC/DC converter VI-R2111-CWWW

VI-R2111-CWWW Parametric

Parameter NameAttribute value
MakerVICOR
Product CategoryIsolated DC/DC converter
Number of outputs3 Output
Input voltage21 VDC to 56 VDC
Output voltage—channel 112 VDC
Output voltage—channel 212 VDC
Insulation voltage3 kV
Installation styleChassis Mount
length124.5 mm
width185.9 mm
high15.7 mm
industryIndustrial
productIsolated
size124.5 mm x 185.9 mm x 15.7 mm
Maximum operating temperature+ 85 C
Minimum operating temperature- 25 C
Output voltage—channel 312 VDC
MegaMod™ &
MegaMod Jr.™ Family
25 to 600 Watts DC-DC Converters Single, Dual, Triple Output Chassis Mount
Features & Benefits
RoHS compliant (VE versions)
Inputs: 10 to 400V
DC
Any output, 1 to 95V
DC
cULus, cTÜVus, CE Marked
80 – 90% Efficiency (Typical)
Up to 27 W/In3
1 Up:
2.58” x 2.5” x 0.62” (Junior)
4.9” x 2.5” x 0.62” (Full Size)
2 Up:
2.58” x 4.9” x 0.62” (Junior)
4.9” x 4.9” x 0.62” (Full Size)
3 Up:
2.58” x 7.3” x 0.62” (Junior)
4.9” x 7.3” x 0.62” (Full Size)
Low noise ZCS power architecture
Booster versions available for
expanded output power –
full size only (add B to part number
Example: VI-LBxx-xx)
Configuration Chart
Substitute VE– for VI– for RoHS compliant versions
Full-Size Modules – MegaMod
Configuration
Single Output
VI-L
-
VI-M
-
F
A
A
F A
VI-N
FF AA
-
F
FF AA
F A
F
Dual Output
A
VI-P
FF AA
-
F A
Junior-Size Modules – MegaMod Jr
# of
Modules Configuration
1
2
3
2
3
3
F FA
F A
F
Triple Output
AA
FF A
F A
A
Output
Power
50 – 200W
100 – 400W
300 – 600W
100 – 400W
F
F
F
A
F
F
A
A
A A
F F
Output
Power
25 – 100W
F
A
# of
Modules
1
Single Output
VI-LJ
-
Dual Output
VI-PJ
-
F
A
F
A
50 – 200W
2
VI-Q
A
F A
Triple
F F F A A
Output
-
-
150 – 600W
150 – 600W
A
VI-R
F F F A A
A
F A
A
VI-RJ
-
F
A A
F F
75 – 300W
3
A
F F AF A A
F A
Input
F
Voltage
Nominal
0 = 12V
[b][c]
V = 24V
[b][c]
1 = 24V
[d]
W = 24V
[d]
2 = 36V
3 = 48V
N = 48V
4 = 72V
T = 110V
5 = 150V
6 = 300V
7 = 150/300V
Max. Output
Per Module
(1)
(2)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
10 – 20V
10 – 36V
21 – 32V
18 – 36V
21 – 56V
42 – 60V
36 – 76V
55 – 100V
66 – 160V
100 – 200V
200 – 400V
100 – 375V
Input Range
Full Power
Maximum Power
(see chart below)
MegaMod
(4)
(2)
(8)
(8)
(6)
(10)
(10)
(9)
(8)
(9)
(10)
(5)
MegaMod Jr.
(1)
(11)
(6)
(6)
(1)
(6)
(5)
(6)
(5)
(6)
(6)
>7.5V
Outputs
75W
75W
75W
100W
100W
150W
150W
200W
200W
50W
F F FF AA
A
F A A
Low Line
Transient
[a]
75% Max Power
n/a
n/a
18V
n/a
18V
36V
n/a
45V
n/a
85V
170V
90V
22
n/a
36
n/a
60
72
n/a
110
n/a
215
425
n/a
Output
Voltage
Z
Y
0
X
W
V
T
R
M
1
P
2
N
3
L
J
K
4
H
F
D
B
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
2V
3.3V
5V
5.2V
5.5V
5.8V
6.5V
7.5V
10V
12V
13.8V
15V
18.5V
24V
28V
36V
40V
48V
52V
72V
85V
95V
A
Product Highlights
Vicor’s MegaMod and MegaMod Jr.
Families of single, dual and triple output
DC-DC converters provide power system
designers with cost effective, high
performance, off-the-shelf solutions to
applications that might otherwise require a
custom supply.
Incorporating standard VI-200 or VI-J00
Family converters in rugged, chassis mount
packages, MegaMod and MegaMod Jr.’s
can be ordered with single, dual or triple
outputs, having a combined output power
of up to 600W. Totally isolated outputs
eliminate efficiency penalties and output
interaction problems.
5 – 7.5V
Outputs
50W
50W
[e]
75W
75W
100W
[f]
100W
150W
150W
200W
50W
(1)
<5V
Outputs
10A
15A
15A
20A
20A
30A
30A
40A
40A
10A
[a]
[b]
[c]
[d]
[e]
[f]
Transient voltage for 1 second.
Single output configurations of 225W are limited to +55°C ambient and are available by special order.
Dual and triple output configurations totaling 225W are limited to +55°C ambient.
Single, dual, and triple output configurations totaling 450W are limited to +55°C.
7.5V output is 75W
6.5V and 7.5V output is 75W
Product Grade Temperature (°C)
MegaMod
E
C
I
M
=
=
=
=
–10 to +85
–25 to +85
–40 to +85
–55 to +85
Output Power/Current
MegaMod
MegaMod Jr.
V
OUT
5V V
OUT
< 5V V
OUT
5V V
OUT
< 5V
Y
=
X
=
W
=
V
=
U
=
50W
75W
100W
150W
200W
Y
=
X
=
W
=
V
=
U
=
10A
15A
20A
30A
40A
Z
=
Y
=
X
=
W
=
25W
50W
75W
100W
Z
= 5A
Y
= 10A
X
= 15A
W
= 20A
MegaMod Jr.
–10 to +100
–25 to +100
–40 to +100
–55 to +100
For on-line product configuration visit:
MegaMod / MI-MegaMod DC-DC
Converters Configurator
Refers to Baseplate Temperature
Output Power/Current
V
OUT
5V
W
V
U
S
Q
=
=
=
=
=
100W
150W
200W
300W
400W
V
OUT
< 5V
W
V
U
S
Q
=
=
=
=
=
20A
30A
40A
60A
80A
Output Power/Current
V
OUT
5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
MegaMod™ & MegaMod Jr.™ Family
Page 1 of 7
Rev 2.3
09/2016
vicorpower.com
800 927.9474
About the extended keyboard LED display of 61 board
I'm a beginner, and I want to ask how to send addresses on a 61 board? Are all its I/O ports data lines? Which is its read and write line? How to connect the expansion 8255? Is there an expansion diag...
flybaby_0 MCU
【TI's First Low Power Design Competition】Research on Lithium Battery Characteristics
[i=s] This post was last edited by 1091424 on 2014-12-13 21:06 [/i] [align=left][b]1. [/b][b]Advantages and characteristics of lithium-ion batteries [/b][/align][align=left] 1) The terminal voltage of...
1091424 Microcontroller MCU
LM3S8962 Learning Experience 2010.5.24
The latest learning experience, the student is now able to write some simple programs, hehe~~~~...
youki12345 Microcontroller MCU
2014 TI League Final Reference Questions
[i=s]This post was last edited by paulhyde on 2014-9-15 02:54[/i]...
youluo Electronics Design Contest
[Application Note] TMP006: Infrared Thermopile Sensor in Ultra-Small Chip-Scale Package
The TMP006 is the first device in a family of temperature sensors that can measure the temperature of an object without making contact with the object. The sensor uses a thermopile to absorb the infra...
EEWORLD社区 Analogue and Mixed Signal
Limitations of Flash_API for C2000 Series (28335) DSP
【Reprint】 API can: 1. Can run in static internal SARAM 2. Configure the correct CPU frequency 3. Integrate API into application according to Flash_API list 4. Initialize PLL control registers, wait fo...
模拟IC Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 102  2316  2794  1764  2164  3  47  57  36  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号