EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-PU03-CUX

Description
Switching power supply VI-PU03-CUX
CategoryPower/power management    Switching power supply   
File Size755KB,7 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-PU03-CUX Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-PU03-CUX - - View Buy Now

VI-PU03-CUX Overview

Switching power supply VI-PU03-CUX

VI-PU03-CUX Parametric

Parameter NameAttribute value
MakerVICOR
Product Categoryswitching power supply
seriesFlatPAC
FlatPAC™
50 to 600 Watts Autoranging, AC-DC Switchers
Features
RoHS compliant (VE versions)
Microcontroller architecture
Inputs: 115/230 Vac autoranging
Meets FCC Part 15, EN55022,
Class B conducted emissions
80 – 90% efficiency
Any output: 1 to 95V
DC
Module enable/disable
(except LU series)
UL, TÜV, CE marked
Remote sense and current limit
BUS OK and AC OK
(except LU series)
40ms ride-through time
OVP and thermal shutdown
1 output; up to 200W
1 or 2 outputs; up to 400W
Configuration Chart
Typical Model: VI-RU
0 1 1
-
E U U U
-
Input
115/230 Vac
A
Output
F F A
1:
5 V
DC
at 200W
2:
12 V
DC
at 200W
3:
12 V
DC
at 200W
Input Characteristics
90–132/180–264 Vac
U
= Autoranging
Configuration
Single Output
Substitute VE– for VI– for RoHS compliant versions
Total
# of
Power
Converters
Dimensions
VI-LU
VI-MU
VI-NU
F
F
F
F
F
F
-
-
-
A
A
A
A
F
A
A
50 – 200W
200 – 400W
F
A
A
1
2
3
300 – 600W
9.25” x 2.5” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 7.3” 1.37”
(234,8 x 185,4 x 34,8mm)
Dual Output
VI-PU
VI-QU
-
-
100 – 400W
150 – 600W
F
A
2
3
1, 2, or 3 outputs; up to 600W
Product Highlights
If y
ou’re looking for the convenience
of a complete, low profile, agency-approved
switching power supply, look no further. The
FlatPAC combines Vicor’s workhorse VI-200
family of DC-DC converters with a modular
package and front-end subassembly to provide
from 50 to 600W of output power from one to
three outputs.
A flat plate heat sink for use in conduction
cooled applications may be specified as an
alternate to the standard finned version by
adding “CC” to the end of the
model number.
F A
F FA FA A
F A
F
Triple Output
VI-RU
F A
A
F FA A
-
150 – 600W
A
3
Output Voltage
A F A A
F F FA F A F
Z
= 2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
A
F
0
= 5V
Y
= 3.3V
X
= 5.2V
Product Grade Temps. °C
Grade
Operating
Storage
E
=
0 to +85
–20 to +100
F
0 to +85
–20 to +100
I
=
–30 to +85
–55 to +100
Temperatures apply to product case.
Output Power/Current
V
OUT
≥5V
V
OUT
< 5V
Y
X
W
V
U
=
=
=
=
=
10A
15A
20A
30A
40A
Y
X
W
V
U
=
=
=
=
=
50W
75W
100W
150W
200W
Vicor’s FlatPAC is also available with a current
controlled output using BatMod converter
modules of 12, 24, or 48V
DC
outputs. This option
is specified by appending “BM” or “BC” (for
conduction cooled versions) to the end of the
FlatPAC model number.
Mixing VI-200 and BatMods in a single
FlatPAC is not permissible.
F
A
C
=
A
Output Power/Current
F
V
A
OUT
≥5V
V
OUT
< 5V
W
= 20A
V
= 30A
U
= 40A
S
= 60A
Q
= 80A
The FlatPAC’s contemporary design allows us to
configure your order quickly and provide rapid
turnaround on standard models. It is truly a
complete power solution, enabling you to spend
more time designing your system and less time
worrying about how to power it.
F A
W
= 100W
V
= 150W
U
= 200W
S
= 300W
Q
= 400W
Output Power/Current
F
A
V
OUT
≥5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
Options
BC
= BatMod/Conduction Cooled
BM
= BatMod
CC
= Conduction Cooled
FlatPAC™
Page 1 of 6
Rev 1.7
09/2016
vicorpower.com
800 927.9474
In bare_metal without an operating system, multiple tasks will exit after running once. How can I run these tasks again?
[i=s]This post was last edited by bjemt on 2017-7-3 14:18[/i] The BLE wireless_usrt sample program provided by NXP is divided into three versions as shown in the figure below:I compared and saw that t...
bjemt NXP MCU
Share "Temperature Measurement and Control"
The full text is as follows...
xu__changhua Analog electronics
Onbao Electronics launches CCFL controller IC series for automotive LCD displays
Following the successful launch of a series of Green model AC-DC PWM power supply control ICs, Onbao Electronics has now launched a series of CCFL controller ICs that can be widely used in LCD monitor...
frozenviolet Automotive Electronics
N ways to play with an LED (V) ---- WatchDog Timer
N ways to play with an LED (V )--WatchDog Timer Author: chenzhufly Email: chenzhufly@126.com 2010-05-02 1. Overview of WatchDog Timer The purpose of the watchdog is to reset the microcontroller after ...
chenzhufly NXP MCU
Wince 6.0 OAL layer initialization LOGO display problem ~
eboot displays a logo, but the middle of the system is black. I want to continue to display the logo in oal. Remove the LCD initialization function call. You can look at the OEMInit function, but I do...
cool8008 Embedded System
Recommended ARM development board
I need to recommend an ARM development board urgently. The requirements are: touch screen; WinCE operating system - you can modify the source code yourself; used for large-scale system integration; pr...
tudi ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1767  2579  2355  1414  575  36  52  48  29  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号