EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-PUZ2-CUU

Description
Switching power supply VI-PUZ2-CUU
CategoryPower/power management    Switching power supply   
File Size755KB,7 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-PUZ2-CUU Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-PUZ2-CUU - - View Buy Now

VI-PUZ2-CUU Overview

Switching power supply VI-PUZ2-CUU

VI-PUZ2-CUU Parametric

Parameter NameAttribute value
MakerVICOR
Product Categoryswitching power supply
seriesFlatPAC
FlatPAC™
50 to 600 Watts Autoranging, AC-DC Switchers
Features
RoHS compliant (VE versions)
Microcontroller architecture
Inputs: 115/230 Vac autoranging
Meets FCC Part 15, EN55022,
Class B conducted emissions
80 – 90% efficiency
Any output: 1 to 95V
DC
Module enable/disable
(except LU series)
UL, TÜV, CE marked
Remote sense and current limit
BUS OK and AC OK
(except LU series)
40ms ride-through time
OVP and thermal shutdown
1 output; up to 200W
1 or 2 outputs; up to 400W
Configuration Chart
Typical Model: VI-RU
0 1 1
-
E U U U
-
Input
115/230 Vac
A
Output
F F A
1:
5 V
DC
at 200W
2:
12 V
DC
at 200W
3:
12 V
DC
at 200W
Input Characteristics
90–132/180–264 Vac
U
= Autoranging
Configuration
Single Output
Substitute VE– for VI– for RoHS compliant versions
Total
# of
Power
Converters
Dimensions
VI-LU
VI-MU
VI-NU
F
F
F
F
F
F
-
-
-
A
A
A
A
F
A
A
50 – 200W
200 – 400W
F
A
A
1
2
3
300 – 600W
9.25” x 2.5” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 7.3” 1.37”
(234,8 x 185,4 x 34,8mm)
Dual Output
VI-PU
VI-QU
-
-
100 – 400W
150 – 600W
F
A
2
3
1, 2, or 3 outputs; up to 600W
Product Highlights
If y
ou’re looking for the convenience
of a complete, low profile, agency-approved
switching power supply, look no further. The
FlatPAC combines Vicor’s workhorse VI-200
family of DC-DC converters with a modular
package and front-end subassembly to provide
from 50 to 600W of output power from one to
three outputs.
A flat plate heat sink for use in conduction
cooled applications may be specified as an
alternate to the standard finned version by
adding “CC” to the end of the
model number.
F A
F FA FA A
F A
F
Triple Output
VI-RU
F A
A
F FA A
-
150 – 600W
A
3
Output Voltage
A F A A
F F FA F A F
Z
= 2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
A
F
0
= 5V
Y
= 3.3V
X
= 5.2V
Product Grade Temps. °C
Grade
Operating
Storage
E
=
0 to +85
–20 to +100
F
0 to +85
–20 to +100
I
=
–30 to +85
–55 to +100
Temperatures apply to product case.
Output Power/Current
V
OUT
≥5V
V
OUT
< 5V
Y
X
W
V
U
=
=
=
=
=
10A
15A
20A
30A
40A
Y
X
W
V
U
=
=
=
=
=
50W
75W
100W
150W
200W
Vicor’s FlatPAC is also available with a current
controlled output using BatMod converter
modules of 12, 24, or 48V
DC
outputs. This option
is specified by appending “BM” or “BC” (for
conduction cooled versions) to the end of the
FlatPAC model number.
Mixing VI-200 and BatMods in a single
FlatPAC is not permissible.
F
A
C
=
A
Output Power/Current
F
V
A
OUT
≥5V
V
OUT
< 5V
W
= 20A
V
= 30A
U
= 40A
S
= 60A
Q
= 80A
The FlatPAC’s contemporary design allows us to
configure your order quickly and provide rapid
turnaround on standard models. It is truly a
complete power solution, enabling you to spend
more time designing your system and less time
worrying about how to power it.
F A
W
= 100W
V
= 150W
U
= 200W
S
= 300W
Q
= 400W
Output Power/Current
F
A
V
OUT
≥5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
Options
BC
= BatMod/Conduction Cooled
BM
= BatMod
CC
= Conduction Cooled
FlatPAC™
Page 1 of 6
Rev 1.7
09/2016
vicorpower.com
800 927.9474
Using the reversing camera
Keyword: [b]Camera[/b] Visual reversing is currently popular among car owners. Reversing rear-view cameras play a big role in ensuring reversing safety, especially in crowded parking lots, places with...
gzycxfj Industrial Control Electronics
Questions about FPGA configuration
As shown in Figure 1, are unused pins configured as "three-state input input" or "three-state input plus weak pull-up"? In Figure 2, why are these dual_purpose_pins set to "use as regular IO"? They ar...
平漂流 FPGA/CPLD
Skype's VoIP network communication protocol has been cracked by a Chinese company
Skype's VoIP internet voice communication protocol has reportedly been reverse engineered by a Chinese company. An employee of the company revealed that they have recently been working on opening up t...
fighting RF/Wirelessly
How to use high-speed ADCs and DACs with FPGAs
...
至芯科技FPGA大牛 FPGA/CPLD
Earn points and settle immediately...
...
weijinping Embedded System
The widespread application of RFID will effectively improve the level of urban management
[Abstract] If RFID is to be used in urban management, there are still many problems, such as security and privacy issues. For example, the RFID chip used in the manhole cover has problems such as data...
tmily RF/Wirelessly

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1564  252  1504  1944  2065  32  6  31  40  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号