Recommended Probes for Low-/Mid-speed Bus Measurements ..............................................................34
Find us at
www.keysight.com
Page 2
Probe Compatibility Table
For ordering information when replacing your probe or probe accessory: Refer directly to the page number listed in the Table of
Contents for your probe model.
To assist you in selecting the proper probe for your application: Use our probe compatibility table below to find the probes that
are recommended for use with your 1000 X-, 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series InfiniiVision
oscilloscope.
Probe type
Passive probes,
page 5
Probe model
N2142A 10:1/1:1 75 MHz (included in 1000 X 50MHz models)
N2140A 10:1/1:1 200 MHz (included in 1000 X 70/100MHz models)
N2862B/N2841A 10:1 150 MHz (included in 70/100 MHz models)
N2863B/N2842A 10:1 300 MHz (included in 200 MHz models)
N2890A/N2843A 10:1 500 MHz (included in 350/500 MHz/1 GHz
models)
N2840A 10:1 50 MHz
N2853A 10:1 350 MHz
N2894A 10:1 700 MHz (included in 4000 X/6000 X models)
N2889A 1:1/10:1 350 MHz
N7007A 10:1 400 MHz
10076C 100:1, 3.7 kV
DSO 1000 X
1
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
MSO/DSO
2000 X
1
MSO/DSO
3000A/T X
MSO/DSO
4000 X/6000 X
2
Recommended
Recommended
Recommended
Recommended
Recommended
Compatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Compatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
High-voltage
passive probe,
page 10
Differential active
probes, page 11
1130B to 1134B 1.5 to 7 GHz
N2750A to N2752A 1.5 to 6 GHz
N2791A 25 MHz
N2891A 70 MHz
N2790A 100 MHz (with AutoProbe)
N2792A 200 MHz
N2818A 200 MHz (with AutoProbe)
N2793A 800 MHz
N2819A 800 MHz (with AutoProbe)
N2804A 300 MHz
N2805A 200 MHz
N2795A 1 GHz (with AutoProbe)
N2796A 2 GHz (with AutoProbe)
N2797A 1.5 GHz (with AutoProbe)
N7020A 2 GHz
01650-61607 16-channel
N2755A 8-channel MSO cable (included in 2000 X-Series MSOs)
N2756A 16-channel MSO cable (included in 3000, 4000, and 6000
X-Series MSOs)
1146B 100 kHz
N2780B 2 MHz (use with N2779A)
N2781B 10 MHz (use with N2779A)
N2782B 50 MHz (use with N2779A)
N2783B 100 MHz (use with N2779A)
1147B 50 MHz (with AutoProbe)
N2893A 100 MHz (with AutoProbe)
N7026A 150 MHz (with AutoProbe)
N2820A 3 MHz/50 µA high sensitivity, 2 channel (with AutoProbe)
N2821A 3 MHz/50 µA high sensitivity, 1 channel (with AutoProbe)
N7040A/41A/42A Rogowski coil
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Compatible
Compatible
Compatible
Compatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Single-ended
active probes,
page 19
MSO logic
probes, page 21
Current probes,
page 23
1. The 1000 X, 2000 X-Series does not support AutoProbe interface active probes.
2. The 4000 X- and 6000 X-Series comes with the Infiniium AutoProbe interface for higher probe power support.
Find us at
www.keysight.com
Page 3
Probe Compatibility Table (Continued)
Probe type
Probe model
DSO5000A
100 MHz
Recommended
Recommended
Compatible
DSO5000A
300 to 500 MHz
Recommended
Recommended
Recommended
MSO/DSO6000A
4
100 MHz
Recommended
Recommended
Compatible
MSO/DSO6000A
4
300 MHz to 1 GHz
MSO/DSO7000A/B
100 MHz to 1 GHz
Compatible
Recommended
Recommended
Passive probes,
page 5
N2863B 10:1 300 MHz (included in 5000
Series 100/300 MHz)
10070D 1:1 20 MHz
10073D 10:1 500 MHz (included in
6000/7000 Series 300 MHz to 1 GHz and
5000 Series 500 MHz)
10074D 10:1 150 MHz (included in 6000
Series 100 MHz)
N2873A 10: 1 500 MHz (optional to 7000B)
N7007A 10:1 400 MHz
10076C 100:1 3.7 kV
Recommended
Recommended
Recommended
Recommended
Compatible
Recommended
Recommended
Recommended
Recommended
Compatible
Recommended
Recomm ended
Compatible
Recommended
Recommended
Recommended
High-voltage
passive probe,
page 10
Differential active
probes, page 11
Single-ended active
probes, page 19
Mixed signal
oscilloscope logic
probes
2
, page 21
Current probes,
page 23
1130B to 1134B 1.5 to 7 GHz
1
N2750A 1.5 GHz
N2791A 25 MHz
N2891A 70 MHz
N2790A 100 MHz (with AutoProbe)
N2792A 200 MHz
N2818A 200 MHz (with AutoProbe)
N2793A 800 MHz
N2819A 800 MHz (with AutoProbe)
N2804A 300 MHz
N2805A 200 MHz
N2795A 1 GHz (with AutoProbe)
N2796A 2 GHz (with AutoProbe)
N2797A 1.5 GHz (with AutoProbe)
N7020A 2 GHz
01650-61607 16-channel
N6450-60001 2x8-channel
(included in MSO6000A, MSO7000A/B)
1146B 100 kHz
N2780B 2 MHz (use with N2779A)
N2781B 10 MHz (use with N2779A)
N2782B 50 MHz (use with N2779A)
N2783B 100 MHz (use with N2779A)
1147B 50 MHz (with AutoProbe)
N2893A 100 MHz (with AutoProbe)
N7026A 150 MHz (with AutoProbe)
N2820A 3 MHz/50 µA high sensitivity,
2 channel (with AutoProbe)
N2821A 3 MHz/50 µA high sensitivity,
1 channel (with AutoProbe)
N7040A/41A/42A Rogowski coil
Compatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Incompatible
Recommended
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Incompatible
Recommended
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Recommended
Recommended
Recommended
Recommended
Incompatible
Recommended
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Incompatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Incompatible
Incompatible
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Recommended
Incompatible
Incompatible
Incompatible
Recommended
1.
The 1130B probe amplifier supports both single- and differential-ended measurements. Higher bandwidth InfiniiMax probe model 1131B, 1132B, and 1134B
are also supported by 3000 X-, 4000 X-, 6000 X-, 5000, 6000 300 MHz to 1 GHz models and, 7000 Series.
2. Recommended for InfiniiVision MSOs only.
3. These Infiniium active probes are not supported by InfiniiVision Series scopes – 1152A, 1153A, 1154A, 1155A, 1159A, 1168A/B, 1169A/B, N2800A, N2801A,
N2802A, N2803A, N2830A, N2831A, N2832A, N7000A, N7001A, N7002A, and N7003A.
4. MSO/DSO6000A 100-MHz models do not support any Keysight active probes with AutoProbe interface.
Find us at
www.keysight.com
Page 4
Passive Probes
– Designed for optimal performance with your Keysight InfiniiVision Series oscilloscopes
– 1:1 and 10:1 attenuation ratio
– 20 to 700 MHz
Rugged, high-quality probes at a reasonable price
Keysight 10070-family passive probes are a great choice if you are looking for high quality at
a very reasonable price. These general-purpose probes are designed specifically to give you
optimal performance with your InfiniiVision Series oscilloscopes. Ruggedized for general-
purpose measurements, they feature a durable cable and a solid stainless steel probe body
encased with a hard, fracture-resistant plastic. They are designed and tested to ensure the
probes operate in the toughest of conditions
The N28xxA/B low-cost, general-purpose passive probes provide up to 500 MHz bandwidth
and feature a high input resistance of 10 MΩ for low probe loading. These probes provide a
10:1 attenuation ratio except for the N2889A, which provides a switch in the probe handle for
switching the attenuation ratio between 1:1 and 10:1. The N284xA and N2853A are the new
version of passive probes with improved frequency response over N2862B/63B/90A probes.
These probes can be used in place of existing N2862B/63B/90A for better performance. The
N2853A is a 10:1 passive probe with 2 m cable length for extended cable connection.
The N2873A/N2894A are 500-MHz/700 MHz 10:1 miniature passive probes that can be used
with all InfiniiVision Series. Compact 2.5-mm probe head diameter, low input capacitance,
and various fine-pitch probe tip accessories make the N2873A/N2894A passive probes ideal
for probing densely populated IC components or surface-mount devices used in today’s
high-speed digital applications. The N2894A provides 700 MHz system bandwidth when used
in conjunction with the 4000 X- and 6000 X-Series ≥ 1 GHz models. For more information
about N2870A Series passive probes and accessories, refer to Keysight’s literature number,
5990-3930EN.
The N2140A 200 MHz and N2142A 75 MHz low-cost passive probes are high-impedance
probes with switchable attenuation ratio (1:1 and 10:1). These are compatible with the Keysight
InfiniiVision EDUX1002A/G and DSOX1102A/G oscilloscopes or similar oscilloscopes with
I recently wrote a program to test the reading and writing of the LPC1788 on-chip EEPROM. The program runs normally when downloaded to the on-chip FLASH, and the initialization and reading and writing...
After the driver was completed, I immediately started to do the necessary tasks to complete this homework. I connected the VBUS with a 5V regulated power supply and used a multimeter to measure the VB...
I recently started working on USB flash drive reading and writing, but I don't know how to operate the data register of LPC1114 to read and write the 376 parallel port? I used to do it with 51, and th...
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
introduction
For the voltage regulator modules (VRMs) that power the latest computer central processing units (CPUs), power supply designers have historically used multiphase interleaved b...[Details]
1 Introduction
As an emerging microfabrication technology, micro-electromechanical system (MEMS) technology has begun to be applied in various fields. It can integrate functions such as inform...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
1 Introduction to HART Protocol
HART (Highway Addressable Remote Transducer), an open communication protocol for addressable remote sensor high-speed channels, was launched by Rosemen in the U...[Details]
Flooded Batteries
This battery developed in Germany can be used to power flashlights, strobe lights and toys as long as it is filled with water. This battery can be stored for 50 years and can...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
As a simple and practical input device, buttons have been used in various microcontroller application systems and are ubiquitous. However, the buttons used in different practical occasions are also...[Details]
1 Introduction
There have been many studies on the detection and protection of power grid short circuit and line fault. The short circuit, overload and overvoltage protectors on the market have ...[Details]
Introduction
Liquid crystal, as a display device, is widely used in low-power products such as instruments, meters, and electronic equipment with its unique advantages. In the past, the displ...[Details]
Single-chip microcomputers are widely used because of their small size, powerful functions and low price. This article introduces the method of designing a micro electronic piano using the AT89C51 sin...[Details]
With the rapid development of the national economy, lifting and hoisting operations are used more and more frequently and widely in various fields of economic construction. China has continuously expl...[Details]
Our flight had just begun to descend when a gentleman sitting next to me turned to talk to me about engineering—he had seen me reading an engineering journal. The gentleman next to me said that he ...[Details]
1 Introduction
With the rapid economic development, my country's electricity demand has been growing at a rate of more than 20% per year. According to the current economic development trend an...[Details]