Part Number

Search

VI-RUBB4-EUUW

Description
Switching power supply VI-RUBB4-EUUW
CategoryPower/power management    Switching power supply   
File Size755KB,7 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-RUBB4-EUUW Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-RUBB4-EUUW - - View Buy Now

VI-RUBB4-EUUW Overview

Switching power supply VI-RUBB4-EUUW

VI-RUBB4-EUUW Parametric

Parameter NameAttribute value
MakerVICOR
Product Categoryswitching power supply
seriesFlatPAC
FlatPAC™
50 to 600 Watts Autoranging, AC-DC Switchers
Features
RoHS compliant (VE versions)
Microcontroller architecture
Inputs: 115/230 Vac autoranging
Meets FCC Part 15, EN55022,
Class B conducted emissions
80 – 90% efficiency
Any output: 1 to 95V
DC
Module enable/disable
(except LU series)
UL, TÜV, CE marked
Remote sense and current limit
BUS OK and AC OK
(except LU series)
40ms ride-through time
OVP and thermal shutdown
1 output; up to 200W
1 or 2 outputs; up to 400W
Configuration Chart
Typical Model: VI-RU
0 1 1
-
E U U U
-
Input
115/230 Vac
A
Output
F F A
1:
5 V
DC
at 200W
2:
12 V
DC
at 200W
3:
12 V
DC
at 200W
Input Characteristics
90–132/180–264 Vac
U
= Autoranging
Configuration
Single Output
Substitute VE– for VI– for RoHS compliant versions
Total
# of
Power
Converters
Dimensions
VI-LU
VI-MU
VI-NU
F
F
F
F
F
F
-
-
-
A
A
A
A
F
A
A
50 – 200W
200 – 400W
F
A
A
1
2
3
300 – 600W
9.25” x 2.5” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 4.9” x 1.37”
(234,8 x 124,5 x 34,8mm)
9.25” x 7.3” x 1.37”
(234,8 x 185,4 x 34,8mm)
9.25” x 7.3” 1.37”
(234,8 x 185,4 x 34,8mm)
Dual Output
VI-PU
VI-QU
-
-
100 – 400W
150 – 600W
F
A
2
3
1, 2, or 3 outputs; up to 600W
Product Highlights
If y
ou’re looking for the convenience
of a complete, low profile, agency-approved
switching power supply, look no further. The
FlatPAC combines Vicor’s workhorse VI-200
family of DC-DC converters with a modular
package and front-end subassembly to provide
from 50 to 600W of output power from one to
three outputs.
A flat plate heat sink for use in conduction
cooled applications may be specified as an
alternate to the standard finned version by
adding “CC” to the end of the
model number.
F A
F FA FA A
F A
F
Triple Output
VI-RU
F A
A
F FA A
-
150 – 600W
A
3
Output Voltage
A F A A
F F FA F A F
Z
= 2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
A
F
0
= 5V
Y
= 3.3V
X
= 5.2V
Product Grade Temps. °C
Grade
Operating
Storage
E
=
0 to +85
–20 to +100
F
0 to +85
–20 to +100
I
=
–30 to +85
–55 to +100
Temperatures apply to product case.
Output Power/Current
V
OUT
≥5V
V
OUT
< 5V
Y
X
W
V
U
=
=
=
=
=
10A
15A
20A
30A
40A
Y
X
W
V
U
=
=
=
=
=
50W
75W
100W
150W
200W
Vicor’s FlatPAC is also available with a current
controlled output using BatMod converter
modules of 12, 24, or 48V
DC
outputs. This option
is specified by appending “BM” or “BC” (for
conduction cooled versions) to the end of the
FlatPAC model number.
Mixing VI-200 and BatMods in a single
FlatPAC is not permissible.
F
A
C
=
A
Output Power/Current
F
V
A
OUT
≥5V
V
OUT
< 5V
W
= 20A
V
= 30A
U
= 40A
S
= 60A
Q
= 80A
The FlatPAC’s contemporary design allows us to
configure your order quickly and provide rapid
turnaround on standard models. It is truly a
complete power solution, enabling you to spend
more time designing your system and less time
worrying about how to power it.
F A
W
= 100W
V
= 150W
U
= 200W
S
= 300W
Q
= 400W
Output Power/Current
F
A
V
OUT
≥5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
Options
BC
= BatMod/Conduction Cooled
BM
= BatMod
CC
= Conduction Cooled
FlatPAC™
Page 1 of 6
Rev 1.7
09/2016
vicorpower.com
800 927.9474
I can't read the value of the variable when using the 430 emulator. I'm a novice, please help me.
IAR is set up correctly and executes correctly, but it does not read variable values...
hanwenli123 Microcontroller MCU
The god of bad luck possessed me, and I bombed for two days
Yesterday, when I was testing an isolation transformer, a wire on the secondary side fell off and touched a wire on the primary side AC220V grid. The transformer was isolated, so it should have been f...
呜呼哀哉 Analog electronics
[STM32F7 Design Contest Invader] Progress Post: Enable FPU for Image Processing
[postbg]bg10.png[/postbg][size=5]After so much trouble, I finally have something good to share with you:victory:[/size] 1. Confirm that FPU is selected when compiling [align=center] [/align][align=lef...
zhanghuichun stm32/stm8
Next-generation LCD development technology
DWIN launches a new generation of human-machine interface DWIN Technology Shenzhen Office Zhang Benxin 0755-83013365 15914114014 dwin2008@126.com In order to achieve rapid development of human-machine...
cewei30mkk Embedded System
DRA7xx Evaluation Module
The Jacinto DRA7xx Evaluation Module platform is designed to accelerate development and time to market for applications such as infotainment, reconfigurable digital clusters or integrated digital cock...
Jacktang Microcontroller MCU
Help complete a simple needs analysis
I need to develop an editor that supports XML. I need to realize: data can be saved in XML format and basic data operations (add, delete, view, modify) can be performed, and data can be synchronized b...
helh Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1894  119  1642  1944  1287  39  3  34  40  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号