DF12.A12WF150C0.2110.1

Description
Mains Power Connector, 2A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The power connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

DF12.A12WF150C0.2110.1 Overview

Mains Power Connector, 2A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

DF12.A12WF150C0.2110.1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Is SamacsysN
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings2A, 250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power Entry Modules with Line Filter
www.schurter.com/pg06
IEC Appliance Inlet C14 with Filter, Circuit Breaker TA45 (recessed)
DF2
Standard- or Medical-Filter
C14
70° C
Description
- Panel Mount:
Screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter DF11
- Substitute for type 5145
Characteristics
- All single elements are already wired
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage- or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Unwired versions
- Line switch 1-pole
- Other rocker marking
- Medical version M80
- Capacitance CX1
Approvals
- VDE License Number: 40012935
- UL License Number: E72928
References
Weblinks
General Product Information
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit Breakers
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC Products

A few high-end DSP+FPGA boards, for those who are destined to have them
They are all good ones taken from normally used machines. You can find the information yourself. 3 pieces for only 500 yuan. I don’t even have enough money for the chips. It’s worth the money if you u...
ylyfxzsx Buy&Sell
Providing antenna flexibility and high performance for mid-range and high-end smartphones
Recently, Qorvo North China Application Engineering Manager Zhang Jie delivered a speech entitled "Providing Antenna Flexibility and High Performance for Mid-range and High-end Smartphones" at EDI CON...
兰博 RF/Wirelessly
2407 io read and write issues
I think it is not appropriate to directly AND IS with A0. If the chip select of DAC is low and effective, then connect IS with A0 in the opposite directionand then connect it to DAC; if the chip selec...
Maywolf Microcontroller MCU
Answer questions to win JD.com cards | "Portfolio of ON Semiconductor and Avnet IoT Innovation Design Competition"
The "Onsemi and Avnet IoT Innovation Design Competition Works Collection" mainly includes the design experience of netizens in the DIY process of the Onsemi and Avnet IoT Innovation Design Competition...
EEWORLD社区 RF/Wirelessly
F7's hardware I2C reading data does not work! ! Help
[i=s] This post was last edited by Tiantianhaoqingqing at 2015-11-9 15:50 [/i] F7 uses hardware I2C to read data from MPU6050, but the program does not run and cannot read data!! I still don’t underst...
天天好心情亲 stm32/stm8
CE 6.0 simulator supports MFC issues
I saw on the Internet that if you manually add the mfc dll corresponding to the cpu under vs2005\vc\ce\dll to NK.bin, the simulator can support MFC APP, but I added it and there is no response. The AP...
less_than Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1197  866  2249  1846  1647  25  18  46  38  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号