EEWORLDEEWORLDEEWORLD

Part Number

Search

KSS089-04TT

Description
IC Socket, SIP89, 89 Contact(s),
Categorysocket   
File Size499KB,4 Pages
ManufacturerAdvanced Interconnections Corp.
Download Datasheet Parametric View All

KSS089-04TT Overview

IC Socket, SIP89, 89 Contact(s),

KSS089-04TT Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerAdvanced Interconnections Corp.
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Other featuresSIP SOCKET
Contact to complete cooperationTIN LEAD OVER NICKEL
Contact completed and terminatedTin/Lead (Sn/Pb) - with Nickel (Ni) barrier
Contact materialBERYLLIUM COPPER
Device slot typeIC SOCKET
Type of equipment usedSIP89
Shell materialPOLYIMIDE
JESD-609 codee0
Number of contacts89
Base Number Matches1
SIP Sockets
Table of Models
SIP Sockets
Molded and Peel-A-Way Insulators
Description:
Peel-A-Way
®
Strips (KSS)
Material: Polyimide Film
Index: -269°C to 400°C (-452°F to 752°F)
®
.005 Typ.
(.13)
Description:
Molded Snap Strips (HSS/HLSS)
Mat’l: Glass Filled Thermoplastic (PPS)
Index: -60°C to 220°C (-76°F to 428°F)
.030 Typ.
(.76)
.095 Typ.
(2.41)
.095 Typ.
(2.41)
Features:
• Available in three body types:
Peel-A-Way
®
Removable Terminal
Carriers, molded Solid Strips, and
molded Snap Strips [breakable at
.100/(2.54mm)].
• Tapered entry for ease of
insertion.
• Multi-finger contacts for reliability.
• Closed bottom sleeve for 100%
anti-wicking of solder.
• Custom configurations available.
Description:
Molded Solid Strips (RNB, RLNB)
Mat’l: High Temp. Liquid Crystal Polymer (LCP)
Index: -40°C to 260°C (-40°F to 500°F)
Head Above
Plastic
.030 Typ.
(.76)
Head Flush
with Plastic
.095 Typ.
(2.41)
.095 Typ.
(2.41)
HSS/HLSS replaces RSS/RLSS and SS/LSS. RNB/RLNB replaces HNB/HLNB and NB/LNB.
Head Above
Plastic
Head Flush
with Plastic
Options
• Removable tape seal protects plated contact in harsh environments.
Tape Seal - add 3M to end of part number
Specifications:
Terminals:
Brass - Copper Alloy
(C36000) ASTM-B-16
Contacts:
Beryllium Copper
(C17200) ASTM-B-194
Solder Preform:
Standard: 63Sn/37Pb
Lead-free: 95.5Sn/4.0Ag/0.5Cu
Plating:
G - Gold over Nickel
M - Matte Tin over Nickel
T - Tin/Lead over Nickel
Gold per ASTM-B-488
Matte Tin per ASTM545-97
Tin/Lead per MIL-P-81728
Nickel per QQ-N-290
• Material - Silicone Backed Polyimide Film, -74°C to 260°C (-100°F
to 500°F) Intermittent to 371°C (700°F)
• Spray flux without contaminating contact area.
• Sealed socket will not allow dirt and other contaminants to enter
socket chamber and become entrapped behind contact fingers.
Dimensional Information
Molded
Body Types
.100 Typ.
(2.54)
.100
(2.54)
A
.095
A Dimension = number of pins X .100/(2.54)
.100
(2.54)
Peel-A-Way
®
Body Types
.100 Typ.
(2.54)
A
A Dimension = [number of pins X .100/(2.54)] + .200/(5.08)
How To Order
KSS
Body Type
RoHS Compliant:
032
-85
M
G
Contact Plating
RoHS Compliant:
KSS - Peel-A-Way
RNB - Molded Solid (head above)
RLNB - Molded Solid (head flush)
HSS* - Molded Snap (head above)
HLSS* - Molded Snap (head flush)
Number of Pins
KSS: 2-100 pos.
HSS/HLSS: 20, 30 or 32 pos.
RNB/RLNB: 3-20, 30 or 32 pos.
G - Gold
T - Tin/Lead
Terminal Plating
RoHS Compliant:
G - Gold
M - Matte Tin
T - Tin/Lead
Terminal Type
See options on next page
5 Energy Way, West Warwick, RI 02893 USA
Tel: 800.424.9850 | 401.823.5200
Fax: 401.823.8723
info@advanced.com | www.advanced.com
Catalog 16A
*PSS Insulators (HSS/HLSS) are not suitable for high temperature, lead-free (RoHS) solder profiles.
Note: Terminals plated with Matte Tin are available only with Gold plated contacts.
Products shown covered by patents issued and/or pending. Specifications subject to change without notice.
inch/(mm)
GC.WaitForPendingFinalizers()
Purpose of GC.WaitForPendingFinalizers() method...
gutouabc123 Embedded System
The use of car high and low beam lights
Can anyone solve the problem of automatic switching of high and low beam lights in cars? The photosensitive design is flawed! Is there any other solution?...
szyouer Automotive Electronics
MSP430 UART sending string problem
Proteus simulation. The received string can be displayed on the virtual terminal, but the display code of LCD1602 cannot display the received string, either it is garbled or not displayed....
enGrave Microcontroller MCU
Operational Amplifiers - The Definitive Guide to Operational Amplifiers
Why is the net input signal E of the op amp also called the error signal in "The Definitive Guide to Operational Amplifiers"? What is the physical meaning?[[i]This post was last edited by BasaraTama o...
BasaraTama Analog electronics
gprs disconnection problem under wince 6.0
Is there any way to prevent the dialed GPRS from being online all the time? I have connected to the DNS server of gprs using dup mode, and the connection is successful. Finally, I sent some data to it...
hjklhu Embedded System
Help: Course Design Addition Counter
[i=s] This post was last edited by paulhyde on 2014-9-15 09:51 [/i] I'm begging for a course design on adder counters! mail:fred1986@tom.com...
fred1986 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1166  2895  1171  1504  241  24  59  31  5  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号