4 Isat1: Peak current for approximately 30% rolloff at +25°C.
5 Isat2: Peak current for approximately 30% rolloff at +125°C.
6 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L *
ΔI
* 10-3, Bp-p : (Gauss),
K: (K-factor from table), L: (inductance in nH),
ΔI
(peak-to-peak ripple current in amps).
7 Part Number Definition: FP1109-xxx-R
• FP1109 = Product code and size
• xxx= Inductance value in
μH,
R = decimal point. If no “R” is present, then
third character = # of zeros
• “-R” suffix = RoHS compliant
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, Isat1
3 Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB pad layout, trace thickness and width, air-flow and proximity of
other heat generating components will affect the temperature rise. It is recommended the part
temperature not exceed 125°C under worst case operating conditions verified in the end
application.
Dimensions-
mm
F ront V iew
T op V iew
S ide V iew
R ecom m ended P ad Layout
S chem atic
2
F P 1 1 0 9 -xxx
w w llyy R
2.5 nom .
(2x)
9.0
m ax
11.2
m ax
11.4
3.0
(2X )
1
2
3.0
(2X )
2.03 ref
4.10 ref
(2X )
1
11.2 m ax
Part Marking: FP1109
xxx = Inductance value in
μH.
(R = Decimal point). If no “R” is present, then last character is # of zeros
wwllyy = Date code
R = Revision level
Packaging
information
- mm
4.00
1.5 dia. +0.1/-0.0
2.00
1.5 dia. min
1.75
Section A-A
1
11.50
FP1109-xxx
wwllyy R
17.5 11.4
24.0 ±0.3
2
9.3
11.4
16.4
2.0
20.00
User direction of feed
Supplied in tape-and-reel packaging, 350 parts per reel, 13” diameter reel.
2
www.eaton.com/electronics
FP1109
High frequency, high current power inductor
Temperature rise
vs
total loss
50
Technical Data
4350
Effective
June
2017
40
Tem perature R ise (°C )
30
20
10
0
0
0 .2
0 .4
0 .6
0 .8
1
1 .2
1 .4
1 .6
T o tal Lo ss (W )
Core
loss
vs Bp-p
100
1MHz
500kHz
10
300kHz
200kHz
100kHz
1
Core Loss (W)
0.1
0.01
0.001
0.0001
0.00001
100
1000
10000
B
p-p
(Gauss)
Inductance characteristics
% o f O C L v s . % o f Is
a t
1
120%
100%
80%
% of OCL
- 4 0 °C
60%
40%
+1 2 5 °C
+2 5 °C
20%
0%
0%
20%
40%
60%
80%
100%
120%
% o f Is
a t
1
www.eaton.com/electronics
3
Technical Data
4350
Effective
June
2017
FP1109
High frequency, high current power inductor
Solder Reflow Profile
T
P
Max. Ramp Up Rate = 3°C/s
Max. Ramp Down Rate = 6°C/s
T
L
Preheat
A
t
t
P
T
C
-5°C
T
ab
l
e
1 -
S
t
a
n
da
r
d S
nP
b S
ol
de
r (T c)
Package
Thickness
<2.5mm
_
>2.5mm
Volume
mm
3
<350
235°C
220°C
Volume
mm
3
_
>350
220°C
220°C
Temperature
T
smax
T
ab
l
e
2 - L
ead
(P
b
) Fr
ee S
ol
de
r (T c)
T
smin
t
s
Package
Thickness
<1.6mm
1.6 – 2.5mm
>2.5mm
Time
Volume
mm
3
<350
260°C
260°C
250°C
Volume
mm
3
350 - 2000
260°C
250°C
245°C
Volume
mm
3
>2000
260°C
245°C
245°C
25°C
Time 25°C to Peak
Reference JDEC J-STD-020
Profile Feature
Preheat
and Soak
• T
e
mperature min. (Tsmin)
• Temperature max. (Tsmax)
• Time (Tsmin to Tsmax) (ts)
Average ramp up rate Tsmax to Tp
Liquidous temperature (T
L
)
Time
at
liquidous (tL)
Peak package
body
temperature (TP)*
Time (tp)** within 5 °C of the specified classification temperature (Tc)
Average ramp-down rate (Tp to Tsmax)
Time 25°C to Peak Temperature
Standard SnPb Solder
100°C
150°C
60-120 Seconds
3°C/
Second
Max.
183°C
60-150 Seconds
Table 1
20
Seconds**
6°C/ Second
Max.
6
Minutes Max.
Lead (Pb) Free Solder
150°C
200°C
60-120 Seconds
3°C/
Second
Max.
217°C
60-150 Seconds
T
able
2
30
Seconds**
6°C/ Second
Max.
8 Minutes Max.
*
Tolerance for peak profile temperature (Tp) is
defined as a
supplier minimum
and a
user maximum.
**
Tolerance for time
at
peak profile temperature (tp) is
defined as a
supplier minimum
and a
user maximum.
Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written
approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly
used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.
Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also
reserves the right to change or update, without notice, any technical information contained in this bulletin.
1. After failing the interview at ZTE, ZTE recommended me to your company. 2. I heard that ZTE was hiring, so I came. 3. I admire Mr. Hou Weigui of your company, so I came to apply. 4. Hello, I am her...
In order to improve the efficiency of I2C, micropython has added a new function: i2c.writevto() The basic form of the function is: i2c.writevto(addr, (buf1, buf2)). It allows writing I2C in the mode o...
Everyone should know that if GPIO is used to simulate SPI, it involves the output high and low levels and read levels of GPIO. Let's first look at the GPIO registers [align=center][/align] (1) GPIOx_C...
Coincidentally, before I received the NUCLEO-L452RE development board, I happened to get an STM32G431 development board at an event. After putting the two together, I felt that the overall difference ...
[i=s]This post was last edited by dontium on 2015-1-23 12:43[/i] “Signal chain” is what TI calls it. What exactly is it? Take a look at its products "...
I saw the legendary WIZwiki-W7500 development board at the Make Faire. This development board is an IOT development board from South Korea with an Ethernet interface. This development board was recomm...
UHF and HF are both general technology categories, but each category has independent supporting protocols. HF is more consistent in the 13.56MHz frequency band, although there are many internation...[Details]
Calibrators are widely used in university experiments. Among them, there are two experiments in nuclear physics experiments in modern physics experiments (GM counter and β absorption) that require ...[Details]
Although improper medical device product design is not always associated with medical device-related errors. Studies of users have shown that lack of adequate training accounts for 70% to 90% of suc...[Details]
1 Introduction
The multifunctional monitor is a commonly used clinical medical device. It can display the patient's electrocardiogram (ECG), respiration (RESP), blood oxygen saturation (SP...[Details]
Medical and industrial applications often require isolation voltages of 2500Vac or higher for patient and equipment operator safety. The isolation barrier must not only transmit power to the sensin...[Details]
For more than 10 years, analog-to-digital converters (ADCs) have been widely used in industrial process control, medical instruments, communication systems, radar and other products as a booster of in...[Details]
The hardware circuit principle is shown in Figure 1. In the specific design, each part should consider the anti-interference problem to minimize the impact of interference on the performance of the...[Details]
In view of the problems in the actual FPGA development process, such as difficulty in locating faults, long compilation time after repeated code modification, and inability to confirm fault solutio...[Details]
This article first briefly introduces the working principles of current mode and voltage mode and their respective advantages and disadvantages; then discusses the ideal voltage mode using output c...[Details]
Today's mobile phone production testing faces an increasingly complex environment, with challenges of multiple frequency bands and multiple standards, pressure on production test speed, and pres...[Details]
introduction
Like other
portable
electronic products,
blood flow parameter detectors
need to be small, thin, durable, reliable, and have a long standby time. Therefore, system desi...[Details]
Preface
For a long time, SD cards with Flash Memory as storage have been widely used in consumer electronic products due to their small size, low power consumption, erasable and non-volati...[Details]
Some application designs have higher requirements on the speed at which the system's switching power supply can provide voltage output. Figure
1
shows
the
bootstrap
...[Details]
A correct circuit design cannot be manufactured 100% correctly when it is taken to the factory for manufacturing. It will always be affected by various uncertainties, such as deviations in manufact...[Details]
Multiple Input and Multiple Output (MIMO) technology is arguably the next most important development in wireless communication technology since the advent of digital communications. Many new wir...[Details]