EEWORLDEEWORLDEEWORLD

Part Number

Search

URB2405D-30WR2

Description
Number of voltage output groups: 1 Maximum input voltage: 36V Output voltage: 5V Output current (maximum value/full load): 6A DC-DC module, input range: 9V~36V, single group output: 5V/6000mA
CategoryPower/power management    DC - DC power supply module   
File Size818KB,7 Pages
ManufacturerMORNSUN
Websitehttp://www.mornsun-power.com
Download Datasheet Parametric View All

URB2405D-30WR2 Overview

Number of voltage output groups: 1 Maximum input voltage: 36V Output voltage: 5V Output current (maximum value/full load): 6A DC-DC module, input range: 9V~36V, single group output: 5V/6000mA

URB2405D-30WR2 Parametric

Parameter NameAttribute value
Power module typeIsolated Module
Number of voltage output groups1
Conversion efficiency88%
Minimum input voltage9V
Maximum input voltage36V
Isolation voltage1.5kVDC
Total output power30W
The output voltage5V
Output current (max/full load)6A
URA_D-30WR2&URB_D-30WR2
SERIES
30W,4:1WIDE
INPUT, ISOLATED & REGULATED
DUAL/ SINGLE OUTPUT DIP DC-DC CONVERTER
FEATURES
Efficiency up to 90%
4:1 wide input voltage range
1500VDC isolation
Six-sided metal shield
Short circuit protection
(automatic recovery)
Operating temperature: -40°C to +85°C
Industry standard pinout
Meet CISP22/EN55022 CLASS A
Patent Protected
RoHS
APPLICATION
URA_D-30WR2&URB_D-30WR2 series offer
30W of output, wide input voltage:9-36VDC,
18-75VDC,
and features 1500VDC isolation, six-sided metal
shield,over current and short circuit protection. All
models are particularly suitable for industrial,
telecommunication,
electric
power,
test
equipments applications.
Input Current
(mA)(typ.)
@Max.
@No
Load
Load
1450
30
1420
680
120
1420
30
30
1450
30
1420
680
100
1420
30
6000
2500
1100
87
88
88
89
2000
1250
86
87
6000
2500
1100
90
88
88
90
Reflected
Ripple
Current
(mA,typ.)
PART NUMBER SYSTEM
URB2405D-30WR2
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
SELECTION GUIDE
Model
Input
Output Output Current (mA)
Voltage(VDC)
Voltage
Nominal
(VDC)
Max.
Min.
(Range) Max
±5
±12
24
(9-36)
±15
40
5
12
15
±5
±12
48
(18-75)
±15
80
5
12
15
6000
2500
2000
300
125
100
6000
2500
2000
±3000
±1250
±1000
300
125
100
±150
±63
±50
±3000
±1250
±1000
±150
±63
±50
Max. Capacitive
Load
(µF)
Efficiency
(%, typ.) @Max.
Load
86
89
URA2405D-30WR2
URA2412D-30WR2
URA2415D-30WR2
URB2405D-30WR2
URB2412D-30WR2
URB2415D-30WR2
URA4805D-30WR2
URA4812D-30WR2
URA4815D-30WR2
URB4805D-30WR2
URB4812D-30WR2
URB4815D-30WR2
2000
1250
Note:
. series with suffix
“H”
are heat sink mounting,for example URB2405D-30WHR2 is with heatsink, URB2405D-30WR2 is without heat sink.
If the application has a higher requirement for heat dissipation, you can choose modules with heat sink.
②.
Absolute maximum rating without damage on the converter,but it isn't recommended.
. For dual output converter, the given value is the same for each output.
INPUT SPECIFICATIONS
Item
Input Surge Voltage (1sec.max.)
Test Conditions
24VDC input
48VDC input
Nominal Input
(24V)
Under Voltage Lockout
Nominal Input
(48V)
Start-up Time
Models ON
Models OFF
Models ON
Models OFF
Min.
-0.7
-0.7
--
7.8
--
16
--
Typ.
--
--
--
--
--
--
10
Max.
50
100
9
--
17.8
--
--
2013.03.12-A/0
Unit
VDC
ms
Page 1 of 7
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URA_D-30WR2&URB_D-30WR2
Design of a dual DSP motor control digital platform
Abstract: Direct torque control has been applied to various control systems of synchronous and asynchronous machines. Due to the Bang-Bang control, long control cycles will lead to two prominent probl...
zbz0529 Power technology
Power Tips: Where to connect the frequency analyzer reference leads for Bode plot measurements - Part 1
Reprinted from: deyisupport Whenever a system contains a negative feedback loop, loop gain T becomes an important performance parameter to measure and optimize stability, output regulation, and transi...
okhxyyo Analogue and Mixed Signal
Cadence Circuit Design Case Analysis
The book "Cadence Circuit Design Case Analysis" is based on Cadence SPB 16.0 version of Cadence. Through a large number of typical examples, it introduces in detail the operation and use of Cadence's ...
arui1999 Download Centre
Oscillation circuit anti-interference problem
I have been struggling with this thing for a while, but overall the improvement is limited, and the optimization of quantity has not yet brought about qualitative optimization. In the figure [color=#f...
qq849682862 Analog electronics
"Fully Digital Controlled TI Solution Power Supply" Project Division of Work and Progress Report
The following is the division of labor among project team members:Division of Labor Person in charge (sorted by internal code) Job DescriptionAuxiliary power supply jishuaihu, lyzhangxiang Input 310V,...
dontium DIY/Open Source Hardware
How to extract the basic signal of digital sampling signal?
In power applications, digital signal sampling, filtering and fundamental extraction are commonly used methods in design. How to extract the fundamental signal contained in the digital sampling signal...
eeleader Industrial Control Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 146  1418  1398  246  134  3  29  5  12  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号