Description
Ceramic Capacitor, Multilayer, Ceramic, 25V, 5% +Tol, 5% -Tol, X7R, 15% TC, 0.022uF, Surface Mount, 0603, CHIP
CategoryPassive components    capacitor   
File Size141KB,8 Pages
ManufacturerAVX
Download Datasheet Parametric View All

BC033C223JZT1SA2 Overview

Ceramic Capacitor, Multilayer, Ceramic, 25V, 5% +Tol, 5% -Tol, X7R, 15% TC, 0.022uF, Surface Mount, 0603, CHIP

BC033C223JZT1SA2 Parametric

Parameter NameAttribute value
Objectid7109713763
package instruction, 0603
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL6.95
capacitance0.022 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.9 mm
JESD-609 codee3
length1.6 mm
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance5%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Embossed, 7 Inch
positive tolerance5%
Rated (DC) voltage (URdc)25 V
size code0603
surface mountYES
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceTin (Sn)
Terminal shapeWRAPAROUND
width0.81 mm
COTS Plus - BC Series
General Specifications
GENERAL DESCRIPTION
Extended range MLCCs for avionic, defense, and space applications have
been available from AVX for many years, typically to customer specification
control documents. The COTS PLUS - BC series now consolidates the main
test options into standard catalog offerings, eliminating the need to generate
custom specifications for each application. Key test options from MIL-PRF-
55681 are applied to BME and PME devices in NP0 and X7R temperature
characteristic dielectrics.
PRODUCT ADVANTAGES
• Higher CV capability than standard PME
• BME and PME technology
• Voltage Range up to 500V
APPLICATIONS
Defense/Aerospace
• Extended Range MLCC for all Applications
• Low weight/payload, small footprint
• Low Voltage Ratings to Maximize Capacitance for High Speed Decoupling
HOW TO ORDER
BC
Series
03
Size
02 = 0402
03 = 0603
05 = 0805
06 = 1206
10 = 1210
12 = 1812
13 = 1825
5
C
102
Capacitance
Code (In pF)
2 Sig. Digits +
Number of
Zeros
K*
Z
T
9
AA
1
Extened Test Level
0 = Not Applicable
1 = DPA IAW EIA-469
2 = 85/85 @ RV for 96 hours
3 = DPA and 85/85 @ RV
Dielectric
Voltage
Z = 10V A = C0G (NP0)
Y = 16V C = X7R
3 = 25V
5 = 50V
1 = 100V
2 = 200V
V = 250V
7 = 500V
Capacitance
Failure Rate
Termination
Tolerance
Z = COTS Plus T = 100% TN
B = ±.10 pF
B = Tin/Lead
C = ±.25 pF
(5% min Lead)
D = ±.50 pF
J = Tin/Lead (60/40)
F = ±1% (≥ 10 pF)
G = ±2% (≥ 10 pF)
J = ±5%
K = ±10%
M = ±20%
* B, C & D tolerance for ≤10 pF values.
Packaging
Base Group A Test Level
1 = 7" T&R
AA = Group A per MIL-PRF-55681
3 = 13" T&R
SA = Group A per MIL-PRF-55681
6 = Waffle Pack
with SLDC
(SLDC = Single Lot Date Code)
9 = Bulk
CONFORMANCE TEST LEVELS
Base Group A Test Options
Voltage Conditioning IAW MIL-PRF-55681
Elevated IR Sample
Visual and Mechanical Inspection
Solderability
Single Lot Date Code (SLDC)
Group A Data Summary
AA
SA
Extended Test Options
Not Applicable
DPA IAW EIA-469
85°C/85% RH @ Rated Voltage / 96 Hrs
DPA and 85/85 @ Rated Voltage
Code
0
1
2
3
081516
1
Beginner's help: Power amplifier design
[font=Arial][size=3][color=#000000]Hello everyone, I am a beginner in analog electronics. Recently, I need to learn to design an amplifier project by myself. I am quite confused, so I came to the foru...
水雷 Analog electronics
Launchpad serial communication programming
Although I often use UART, today when I used launchpad to perform serial communication, I found that I still had a vague feeling about serial communication, especially serial communication program wri...
qiwan Microcontroller MCU
Compile error problem
I was reading teacher Xia Yuwen's book and saw a program. I input this program into Quartus II, but there was an error when compiling. The program is as follows: `include "Top.v" `include "Block.v" `i...
chenbingjy FPGA/CPLD
AD15 Help, help, help
drop..........
嘟嘟噜嘟嘟 Analog electronics
Motor Control - Brushed DC Motor Overview
[i=s]This post was last edited by dontium on 2015-1-23 13:13[/i]Motor Control - Brushed DC Motor OverviewThe brushed DC motor is one of the oldest motor topologies in existence. Despite their many dis...
德州仪器 Analogue and Mixed Signal
Can the special rate be calculated?
Why is my calculation different from the example? 100KBPS/S in the example: the settings are as follows (using an external crystal (is it 8M?), SYSCLK is HSE, and the CAN clock should be 4M! CAN_InitS...
wchq1 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1218  303  1227  328  867  25  7  18  52  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号