EEWORLDEEWORLDEEWORLD

Part Number

Search

BC061C152KZJ1SA2

Description
Ceramic Capacitor, Multilayer, Ceramic, 100V, 10% +Tol, 10% -Tol, X7R, 15% TC, 0.0015uF, Surface Mount, 1206, CHIP
CategoryPassive components    capacitor   
File Size141KB,8 Pages
ManufacturerAVX
Download Datasheet Parametric View All

BC061C152KZJ1SA2 Overview

Ceramic Capacitor, Multilayer, Ceramic, 100V, 10% +Tol, 10% -Tol, X7R, 15% TC, 0.0015uF, Surface Mount, 1206, CHIP

BC061C152KZJ1SA2 Parametric

Parameter NameAttribute value
Objectid7109943923
package instruction, 1206
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL5.48
capacitance0.0015 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.94 mm
JESD-609 codee0
length3.2 mm
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance10%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Embossed, 7 Inch
positive tolerance10%
Rated (DC) voltage (URdc)100 V
size code1206
surface mountYES
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceTin/Lead (Sn60Pb40)
Terminal shapeWRAPAROUND
width1.6 mm
COTS Plus - BC Series
General Specifications
GENERAL DESCRIPTION
Extended range MLCCs for avionic, defense, and space applications have
been available from AVX for many years, typically to customer specification
control documents. The COTS PLUS - BC series now consolidates the main
test options into standard catalog offerings, eliminating the need to generate
custom specifications for each application. Key test options from MIL-PRF-
55681 are applied to BME and PME devices in NP0 and X7R temperature
characteristic dielectrics.
PRODUCT ADVANTAGES
• Higher CV capability than standard PME
• BME and PME technology
• Voltage Range up to 500V
APPLICATIONS
Defense/Aerospace
• Extended Range MLCC for all Applications
• Low weight/payload, small footprint
• Low Voltage Ratings to Maximize Capacitance for High Speed Decoupling
HOW TO ORDER
BC
Series
03
Size
02 = 0402
03 = 0603
05 = 0805
06 = 1206
10 = 1210
12 = 1812
13 = 1825
5
C
102
Capacitance
Code (In pF)
2 Sig. Digits +
Number of
Zeros
K*
Z
T
9
AA
1
Extened Test Level
0 = Not Applicable
1 = DPA IAW EIA-469
2 = 85/85 @ RV for 96 hours
3 = DPA and 85/85 @ RV
Dielectric
Voltage
Z = 10V A = C0G (NP0)
Y = 16V C = X7R
3 = 25V
5 = 50V
1 = 100V
2 = 200V
V = 250V
7 = 500V
Capacitance
Failure Rate
Termination
Tolerance
Z = COTS Plus T = 100% TN
B = ±.10 pF
B = Tin/Lead
C = ±.25 pF
(5% min Lead)
D = ±.50 pF
J = Tin/Lead (60/40)
F = ±1% (≥ 10 pF)
G = ±2% (≥ 10 pF)
J = ±5%
K = ±10%
M = ±20%
* B, C & D tolerance for ≤10 pF values.
Packaging
Base Group A Test Level
1 = 7" T&R
AA = Group A per MIL-PRF-55681
3 = 13" T&R
SA = Group A per MIL-PRF-55681
6 = Waffle Pack
with SLDC
(SLDC = Single Lot Date Code)
9 = Bulk
CONFORMANCE TEST LEVELS
Base Group A Test Options
Voltage Conditioning IAW MIL-PRF-55681
Elevated IR Sample
Visual and Mechanical Inspection
Solderability
Single Lot Date Code (SLDC)
Group A Data Summary
AA
SA
Extended Test Options
Not Applicable
DPA IAW EIA-469
85°C/85% RH @ Rated Voltage / 96 Hrs
DPA and 85/85 @ Rated Voltage
Code
0
1
2
3
081516
1
Three-degree-of-freedom robotic arm
[i=s]This post was last edited by paulhyde on 2014-9-15 04:01[/i] Three-degree-of-freedom robotic arm ppt...
gh001 Electronics Design Contest
Hello everyone! Let me show you the single power supply amplifier diagram
:) Hello everyone! Here is a diagram of a single power supply amplifier....
brightpeng Power technology
VirtualStart Issues
Regarding the problem of VirtualStart, I have read almost all the posts about virtual addresses on the forum, but the light still does not work during debugging. I am depressed. Please help me take a ...
goo128 Embedded System
Monochrome screen upgrade: How to quickly upgrade the DWIN T5UIC1 color screen
[align=left][b][color=black][font=TimesNewRomanPS-BoldMT][size=11.0pt]1. [/size][/font][/color][/b][color=black][font=宋体][size=11pt]Why upgrade to color screen? [/size][/font][/color][/align][align=le...
DWIN_IOT Industrial Control Electronics
Intelligent management tools used by power operation and maintenance personnel
Electric power operators have to operate, inspect, and perform routine maintenance every day, and test and rotate equipment regularly. If a fault occurs, they have to go to the site to check and deter...
LivingLab1 Industrial Control Electronics
Indicators to consider when selecting a power supply
Any test of a component, board, module, or device requires the use of one or more DC power supplies to power the DUT and the test stimulus source. In addition to powering the DUT, these power supplies...
一世轮回 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2927  418  1748  1405  1917  59  9  36  29  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号