EEWORLDEEWORLDEEWORLD

Part Number

Search

BC061C222KZT9SA0

Description
Ceramic Capacitor, Multilayer, Ceramic, 100V, 10% +Tol, 10% -Tol, X7R, 15% TC, 0.0022uF, Surface Mount, 1206, CHIP
CategoryPassive components    capacitor   
File Size141KB,8 Pages
ManufacturerAVX
Download Datasheet Parametric View All

BC061C222KZT9SA0 Overview

Ceramic Capacitor, Multilayer, Ceramic, 100V, 10% +Tol, 10% -Tol, X7R, 15% TC, 0.0022uF, Surface Mount, 1206, CHIP

BC061C222KZT9SA0 Parametric

Parameter NameAttribute value
Objectid7109945761
package instruction, 1206
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL7.3
capacitance0.0022 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.94 mm
JESD-609 codee3
length3.2 mm
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance10%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingBulk
positive tolerance10%
Rated (DC) voltage (URdc)100 V
size code1206
surface mountYES
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceTin (Sn)
Terminal shapeWRAPAROUND
width1.6 mm
COTS Plus - BC Series
General Specifications
GENERAL DESCRIPTION
Extended range MLCCs for avionic, defense, and space applications have
been available from AVX for many years, typically to customer specification
control documents. The COTS PLUS - BC series now consolidates the main
test options into standard catalog offerings, eliminating the need to generate
custom specifications for each application. Key test options from MIL-PRF-
55681 are applied to BME and PME devices in NP0 and X7R temperature
characteristic dielectrics.
PRODUCT ADVANTAGES
• Higher CV capability than standard PME
• BME and PME technology
• Voltage Range up to 500V
APPLICATIONS
Defense/Aerospace
• Extended Range MLCC for all Applications
• Low weight/payload, small footprint
• Low Voltage Ratings to Maximize Capacitance for High Speed Decoupling
HOW TO ORDER
BC
Series
03
Size
02 = 0402
03 = 0603
05 = 0805
06 = 1206
10 = 1210
12 = 1812
13 = 1825
5
C
102
Capacitance
Code (In pF)
2 Sig. Digits +
Number of
Zeros
K*
Z
T
9
AA
1
Extened Test Level
0 = Not Applicable
1 = DPA IAW EIA-469
2 = 85/85 @ RV for 96 hours
3 = DPA and 85/85 @ RV
Dielectric
Voltage
Z = 10V A = C0G (NP0)
Y = 16V C = X7R
3 = 25V
5 = 50V
1 = 100V
2 = 200V
V = 250V
7 = 500V
Capacitance
Failure Rate
Termination
Tolerance
Z = COTS Plus T = 100% TN
B = ±.10 pF
B = Tin/Lead
C = ±.25 pF
(5% min Lead)
D = ±.50 pF
J = Tin/Lead (60/40)
F = ±1% (≥ 10 pF)
G = ±2% (≥ 10 pF)
J = ±5%
K = ±10%
M = ±20%
* B, C & D tolerance for ≤10 pF values.
Packaging
Base Group A Test Level
1 = 7" T&R
AA = Group A per MIL-PRF-55681
3 = 13" T&R
SA = Group A per MIL-PRF-55681
6 = Waffle Pack
with SLDC
(SLDC = Single Lot Date Code)
9 = Bulk
CONFORMANCE TEST LEVELS
Base Group A Test Options
Voltage Conditioning IAW MIL-PRF-55681
Elevated IR Sample
Visual and Mechanical Inspection
Solderability
Single Lot Date Code (SLDC)
Group A Data Summary
AA
SA
Extended Test Options
Not Applicable
DPA IAW EIA-469
85°C/85% RH @ Rated Voltage / 96 Hrs
DPA and 85/85 @ Rated Voltage
Code
0
1
2
3
081516
1
How to extract the basic signal of digital sampling signal?
In power applications, digital signal sampling, filtering and fundamental extraction are commonly used methods in design. How to extract the fundamental signal contained in the digital sampling signal...
eeleader Industrial Control Electronics
Electronics Contest Topic Analysis
[i=s]This post was last edited by paulhyde on 2014-9-15 09:23[/i] Analysis of the topic of the electronic competition...
dtcxn Electronics Design Contest
How to get the handle of an already opened device in WINCE6.0
RT, I know the name of the device, but I don't know the handle of the device. Dear seniors, is there any function or method to get the handle of the device when I know the device name? Or by searching...
arkin Embedded System
Please help! Questions about FAT32...
The limit of FAT32 in Windows seems to be 30GB. I have a 60G hard disk, which I formatted into FAT32 using a partition tool (more than 30GB cannot be formatted into FAT32 in Windows). It can also be u...
无域思维 Embedded System
Profibus bus alarm problem
One of the circular processing lines in the unit uses CPU313-2DP as the PLC, with 6 ET200ECO stations and 6 ET200S stations. For a period of time, there was such a phenomenon that the line stopped mov...
jek9528 Industrial Control Electronics
US states ban bisphenol A (BPA)
BPA has been widely used in commercial applications since the 1950s to prevent plastics from breaking. In the United States, BPA is produced at an annual rate of 2 billion pounds. It is very common in...
ponysh Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 504  2100  1752  2140  1456  11  43  36  44  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号