EEWORLDEEWORLDEEWORLD

Part Number

Search

006024018552003

Description
Card Edge Connector, 18 Contact(s), 1 Row(s), Straight, Solder Terminal,
CategoryThe connector    The connector   
File Size25KB,1 Pages
ManufacturerAVX
Download Datasheet Parametric View All

006024018552003 Overview

Card Edge Connector, 18 Contact(s), 1 Row(s), Straight, Solder Terminal,

006024018552003 Parametric

Parameter NameAttribute value
MakerAVX
Reach Compliance Codecompliant
Is SamacsysN
Connector typeCARD EDGE CONNECTOR
Contact to complete cooperationGOLD (10) OVER NICKEL
Contact completed and terminatedGOLD (10) OVER NICKEL
DIN complianceNO
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Manufacturer's serial number6024
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded1
OptionsGENERAL PURPOSE
Terminal pitch3.96 mm
Termination typeSOLDER
Total number of contacts18
UL Flammability Code94V-0
Base Number Matches1
.156" x .200"
Features
Extended card guides
Ribbon-type contacts with bifurcated
nose
Choice of terminations: solder (wire
hole and P.C. tab), or low-cost
solderless wrap contacts
For 1/16" P card
.C.
Contact plating:*
Overall:
50-100 microinches nickel and 10
microinches min. gold overall
Insertion/withdrawal force:
2 to 16
ounces per contact pair, nominal P.C.
card
Insulator material:
Polyester per UL 94VO
Insulation resistance:
5000 megohms,
minimum
Dielectric withstanding voltage:
1800
VAC between adjacent contacts, RMS,
at sea level
SERIES 6022/6024
Rectangular Tails
Series 6007 Contacts
Specifications
Current rating:
5 amperes
Contact resistance:
6 milliohms,
maximum
Contact material:
Phosphor bronze
* For other type platings and thicknesses please
consult factory.
Ordering Code
Typical Example
00
6024
6022
044
450
001
SERIES
6022
NUMBER OF CONTACTS
6022
6024
Single Readout
22
Dual Readout
44
Single Readout
18
Dual Readout
36
CONTACT CODE
Single Read-Out
552
60-6007-16-33 P.C. tab (single sided): .202" lg.
936
60-6007-06-43 Wrap (.016" x .047") special: .497" lg.
938
60-6007-06-33 P.C. tab special: .215" lg.
940
60-6007-06-23 Wire hole special: .227" lg.
Dual Read-Out
450
60-6007-19-23 Wire hole: .277" lg.
1
451
60-6007-19-33 P.C. tab: .202" lg.
452
60-6007-18-13 Solderless wrap (.016" x .044"): .697" lg.
453
60-6007-18-23 P.C. tab: .347" lg.
454
60-6007-18-33 Solderless wrap (.016" x .044"): .517" lg.
498
60-6007-05-33 Switching (used in pairs): .202" lg. P.C. tab
941
60-6007-05-13 Switching (used in pairs): .229" lg. wire hole
VARIATION CODE
6022
Plating
Overall
001
44 Dual read-out contacts
installed in all positions
002
22 Single read-out contacts
installed on numbered side
only (551, 552, 936, 938, 940)
003
22 Single read-out contacts
installed on lettered side only
(551, 552, 936, 938, 940)
004
22 Single read-out contacts
installed staggered starting with
position 1, B, 3, D, etc. (936,
938, 940 only)
005
22 Single read-out contacts
installed staggered starting with
position A, 2, C, 4, etc. (936,
938, 940 only)
6024
Plating
Overall
001
Dual read-out contacts
002
Single read-out contacts with
tails in position “1” to “18”
(551, 552, 936, 938, 940)
003
Single read-out contacts with
tails in positions “A” to “V”
(551, 552, 936, 938, 940)
004
Single read-out contacts with
tails in positions 1-B-3, etc.
(936, 938, 940 only)
005
Single read-out contacts with
tails in positions A-2-C, etc.
(936, 938, 940 only)
6
89C51 makes remote control high and low 8-bit user identification code through hexadecimal P0 P1 LED display test question
I connected 16 LED lights with P0 P1. When executing the following program instructions, the P1 port displayed the hexadecimal lower 8-bit user code, and the P0 port displayed the upper 8-bit user cod...
白鹤亮翅 Embedded System
Why can't I find the IE control in the component added in my EVC? How can I add the IE control?
Why can't I find the IE control in the component added in my EVC? How can I add the IE control? Does EVC not have IE control? My EVC4.0 SDK 4.2...
hhyyzzcool Embedded System
First aid, the SDAuthutilDevice.exe verification tool cannot be executed on the PDA, and it prompts an illegal WINCE program. Please help me
I use a CASIO IT-500 PDA, the CPU is ARM XScale, the platform is WINCE.net, and I want to use VS2003 to write a database program on it. As a result, I manually copied the \ARM\SDAuthutilDevice.exe fil...
disasterhe Embedded System
Newbie consultation on MOS tube switch circuit
[i=s] This post was last edited by appzengh on 2017-12-19 13:59 [/i] I made a 6V/8.4V switching output circuit controlled by a dual switch using PMOS. Please take a look at it to see if there are any ...
appzengh Analog electronics
4.5V to 17V Input, 3.3V Output, High Efficiency DC/DC Converter
This reference design is intended to power an MSP430 device with an input voltage range of 4.5V to 17.0V....
莫妮卡 Analogue and Mixed Signal
How to open a window in Altium Designer?
[size=4]When doing PCB layout, I often hear people talking about windowing. What is windowing? What is the use of windowing? How to open a window? Today, let's take a look at PCB windowing. [/size] [s...
qwqwqw2088 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 970  1596  136  2092  1262  20  33  3  43  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号