NHG RELAYS
P
R
14.0
9.0 5.0
E158859
R5604271
Patent No 02217796.5
C
US
Features
DIL Pitch Terminals .High Sensitivity :0.14W or 0.10W Nominal Power
Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC
Monostable or bistable relays Single and double Coil magnet latching Type available
Application for Telecommunication Equipment,Office Equipment,Security Alarm Systems, Measuring instruments,
Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control
Ordering Information
P
L
12 W
NIL: Single Side Stable
L:1 Coil Latching; K:2 Coil Latching
3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24
4 Contact material NIL: AgPd W: AgNi
1
2
3
4
1 Part number P
2 Operating function
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or
Voltage drop
Operation
life
Electrical
Mechanical
2C DPDT(B-M)
Bifurcated Crossbar
AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad
1A,2A/30VDC; 0.5A/125VAC
60W
62.5VA
Min. Switching load 0.01mA/10mV Reference Value
220VDC 250VAC
M ax. Swit ching Curr ent:2A
50m
1A/30VDC 2 10
5
Ag Ni 1 10
5
0.5A/125VAC 1 10
5
10
8
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
DC or peak AC
open circuit are not
CAUTION:
Relays previously tested or used above 10mA resistive at 6V maximum
recommended for subsequent use in low level applications.
Coil Parameter
Dash
numbers
P-003
P-004
P-005
P-006
P-009
P-012
P-024
Coil voltage
VDC
Rated
3
4.5
5
6
9
12
24
3
4.5
5
6
9
12
24
3
4.5
5
6
9
12
24
Max.
7.5
11.25
12.5
15.0
22.5
30.0
48.0
8.7
13.0
14.5
17.4
26.1
34.8
57.6
Coil resistance
10%
64.3
144.6
178
257
579
1028
2880
90
202.5
250
360
810
1440
3840
Set Coil
Reset Coil
Pick up voltage
VDC(max)
(75%of rated
voltage )
2.25
3.38
3.75
4.50
6.75
9.00
18.0
2.25
3.38
3.75
4.50
6.75
9.00
18.0
2.25
3.38
3.75
4.50
6.75
9.00
18.0
Release voltage
VDC(min)
(10% of rated
voltage)
0.3
0.45
0.5
0.6
0.9
1.2
2.4
Coil
power
W
0.14
0.14
0.14
0.14
0.14
0.14
0.20
0.10
0.10
0.10
0.10
0.10
0.10
0.15
0.20
0.20
0.20
0.20
0.20
0.20
0.30
Operate
Time
ms
Release
/Reset
Time
ms
Approx.2
Approx.1
1 Coil Latching
PL-003
PL-004
PL-005
PL-006
PL-009
PL-012
PL-024
Reset(Max)
-2.25
-3.38
-3.75
-4.50
-6.75
-9.00
-18.0
Reset
Approx.2
Approx.1
2 Coil Latching
PK-003
PK-004
PK-005
PK-006
PK-009
PK-012
PK-024
6
9
10
12
18
24
36
Reset(Max)
2.25
3.38
3.75
4.50
6.75
9.00
18.0
Reset
45
101
125
180
405
720
1920
45
101
125
180
405
720
1920
Approx.2
Approx.1
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design
criteria.
3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed
simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width
should be a minimum of three times the specified operate time of the relay. If these conditions are not
followed, it is possible for the relay to be in the magnetically neutral position .